EUKYX 1-3 199-2100 2.1 Local Window [2] Graphic Displa y Area The graph ic imag e of the PCB transfer and component i nput se ctions is d isp la yed in thi s area. The di splayed cont ents will d if f er depending on sel…

100%1 / 327
EUKYX
1-2199-2100
2. "Product" Window
2. "Product" Window
2.1 Local Window
This window enables you to view the current operation status and production condition such as the
production model names (pattern program names), etc., and the information on the prospective number
of finished PCBs and presumable deterioration in the operation rate based on pickup errors, etc.
[1]
[3]
[4]
[5]
[2]
Graphic
Development
MTN:NotRdy RCG:NotRdy
F2A2
[1] “Product.” Main Menu Bar
[Product.]
Main Menu
Opens the "Product" window. In normal cases,
this window opens as an initial one.
[Comp.Reld.]
Main Menu
Opens the "Comp.Reload" window.
Refer to "3. "Comp.Reload" Window"
for details .
[Operation]
Main Menu
Opens the "OPERATION" window.
Refer to "4. "OPERATION" Window"
for details.
[Prod.Dt.]
Main Menu
Opens the "Prod.Dt." window.
:
[Manage]
Main Menu
Opens the "Manage" window.
Refer to "Management Data in chapter 4" for
details.
:
[Recall]
Main Menu
:
:
:
:
Reference
Reference
Reference
Opens the "Recall" window.
Refer to "Recall in chapter 5" for details.
Reference
Refer to "Pattern Program in chapter 2" and
"Component Library in chapter 3" for details.
Reference
F2A3
EUKYX
1-3199-2100
2.1 Local Window
[2] Graphic Display Area
The graphic image of the PCB transfer and component input sections is displayed in this area.
The displayed contents will differ depending on selection of the options.
(2) Feeder status
(Pick-up Rate)
201 to 260
(Feeder
Component Data)
PCB Process
Status
101 to 160
(Feeder Component
Data)
Placement
Step Count
(3)
(4)
(1)
F2A4
(1) Local / Line Change Buttons
Using these buttons, the graphic display section is changed.
When the line consists of a single unit, the line control change button is not displayed.
[Local] Button : When this button is pressed, the graphic image of the single machine is
displayed.
[Line] Button : When this button is pressed, the graphic image of the line is displayed.
The line start or line stop after the completed PCB is discharged from the
line, is performed.
Refer to ”2.2 Line Window in chapter 1 for the details.
Note
Note
Reference
EUKYX
1-4199-2100
2.1 Local Window
(2) Feeder Status
The current status of the feeder base is classified by color and displayed. How to understand the
status of each color is as follows.
Red
: There are some feeders of which pick-up rate is remarkably dropped.
Yellow
: There are some feeders of which pick-up rate is dropped.
Green
: The pick-up condition is normal.
Gray
: It shows an unused feeder.
The component reload data for the corresponding feeder is displayed in this section.
Green
: All feeders are normal.
Yellow
: There are some feeders for which the close attention is required, such as the
feeders with the component shortage alarm.
Red
: There are some feeders which can not be used because of component shortage
or because the feeder has not been installed.
Gray
: It shows an unused feeder.
(3) [Cover READY] Buttons
Using this button, the transparent cover lock/unlock status is displayed.
Refer to “2.2.2 Feeder Ready Switches and Cover Lock Switches” in "Chapter 1 (Vol. 1)" for
the cover lock switches on the main body of the machine.
(4) Product PCB Status
The PCB under placement is shown in dark green and the standby PCB is shown in pale green.
Reference