EUKYX-199-2100_G5S2_Instruction_Vol2_E - 第58页

EUKYX 1-8 199-2100 2.2 Line Window 2. 2 L ine Wind ow Thi s wi ndow enab les the operator to c heck the production l ine operati on status and operate the l ine . In thi s wi ndow , the o peratio n status of the SIGMA se…

100%1 / 327
EUKYX
1-7199-2100
2.1 Local Window
Component Handling Rate Data
The data of the feeder where the pick-up rate has been dropped, is displayed.
F2A8
PCB completion cycle
Max. 500 items of the measured finishing interval (interval between the previous PCB and the
current PCB at the final step completion) are displayed from the newest.
(a) Because the interval cannot be measured before the second PCB is completed, "---" is
displayed at the first PCB finished time.
(b) In the case that the placement status becomes "Stopping" or "Pause", the measurement of
the PCB is stopped and "---" is displayed.
(c) The history is automatically saved in "D:\mdata\MachDt\PcbInt.csy" when the whole
status becomes "Stopping".
F2A9
[5] Stop Mode
[All PCB out] Button
After the PCB in the course of the production, has been produced, the PCB is discharged
and the automatic production operation is stopped.
[Cycle] Button
When the component placement operations on the PCBs in the course of the production in
each of the stage 1 and stage 2, have been completed, the automatic production operation is
stopped.
Note
EUKYX
1-8199-2100
2.2 Line Window
2.2 Line Window
This window enables the operator to check the production line operation status and operate the
line. In this window, the operation status of the SIGMA series machines (including the printer) set in
the line configuration, PCB transfer unit graphic image and production data are displayed.
[1]
[6]
[5]
[7]
[3]
[4]
[5]
[2]
Graphic
Development
F2A10
[1] Local / Line Change Buttons
Using these buttons, the Local window is changed to or from the Line window.
[2] No.
In this area, the machine Nos. in the line are displayed.
[3] Operation Status
In this area, the operation status of each machine in the line, is displayed.
RUN : This machine is under operation.
STOP : This machine is shut down.
PAUSE : This machine is stopped temporarily.
[4] PCB transfer section
In this area, the operation status of each machine in the line, is displayed.
Green : PCB present
Gray : PCB absent
[5] Feeder Base Unit
In this area, the presence or absence of the feeder base is displayed.
EUKYX
1-9199-2100
2.2 Line Window
[6] Line Ctrl
[Start] Button (Line Start)
When this button is pressed and the [Start] button on the operation panel is pressed, the machines
(including the printer) in the line, are started up together.
(a) The start-up operation is available from any machine in the line.
(b) Press the start button after all the machines to be operated have been set to production
READY condition. When any of the machines has not been set to production READY
condition, the start-up together is not available.
(c) When the machines are started up together, the tower light flashes for three seconds and
the buzzer sounds.
[Product] Button (Line Discharge)
When this button is pressed, the PCB discharge stop is performed in the machines in the line from
the upstream machine.
This operation is available from any machine in the line.
[7] Production Data
The production data for the SIGMA Series line is displayed in this area.
Prod PCB
The product PCB production completion time is displayed in this data box.
Process time
The product PCB production completion time is displayed in this data box.
(The PCB completion time on the pattern program management data is displayed in this data
box).
Rate of err [%]
The product model pick-up error rate is displayed in this data box.
(The pick-up error rate on the pattern program management data is displayed).
Note
Note