EUKYX-199-2100_G5S2_Instruction_Vol2_E - 第60页

EUKYX 1-10 199-2100 3. "Comp.Reload" Window 3 . " Comp .Reload " Window Graphic Development [1] [3] [4] [2] [7] [6] [5] [8] [9] [11] [13] [12] [10] F2A1 1 The dis played cont ents will d iff er depend…

100%1 / 327
EUKYX
1-9199-2100
2.2 Line Window
[6] Line Ctrl
[Start] Button (Line Start)
When this button is pressed and the [Start] button on the operation panel is pressed, the machines
(including the printer) in the line, are started up together.
(a) The start-up operation is available from any machine in the line.
(b) Press the start button after all the machines to be operated have been set to production
READY condition. When any of the machines has not been set to production READY
condition, the start-up together is not available.
(c) When the machines are started up together, the tower light flashes for three seconds and
the buzzer sounds.
[Product] Button (Line Discharge)
When this button is pressed, the PCB discharge stop is performed in the machines in the line from
the upstream machine.
This operation is available from any machine in the line.
[7] Production Data
The production data for the SIGMA Series line is displayed in this area.
Prod PCB
The product PCB production completion time is displayed in this data box.
Process time
The product PCB production completion time is displayed in this data box.
(The PCB completion time on the pattern program management data is displayed in this data
box).
Rate of err [%]
The product model pick-up error rate is displayed in this data box.
(The pick-up error rate on the pattern program management data is displayed).
Note
Note
EUKYX
1-10199-2100
3. "Comp.Reload" Window
3. "Comp.Reload" Window
Graphic
Development
[1]
[3]
[4]
[2]
[7]
[6]
[5]
[8]
[9]
[11] [13]
[12]
[10]
F2A11
The displayed contents will differ depending on selection of the options.
[1] Select block
When each block button is pressed, the “[2] List of Feeders” pane shows the feeder information of
the corresponding block.
Note
EUKYX
1-11199-2100
3. "Comp.Reload" Window
[2] "List of Feeders" Pane
Fdr No.
The condition of each feeder is color-coded. When a component shortage error has occurred
in a feeder, the background color of the feeder No. turns red.
According to your judgment based on the color codes, components can also be supplied to
the other feeders together with the error-caused feeder.
Red
: Feeder Unavailable (Component Shortage Error, Feeder Not Installed, etc.)
Pink
: Feeder that requires splicing
Yellow
: Attention Required Feeder (Warning of Component Shortage, etc.)
Green
: The feeders are normal.
Gray
: Not selected feeder (specified as "Not Used") in the pattern program
Component ID
Displayed are the component IDs.
Splicing
When the splicing function in each feeder has been enabled, it is displayed in blue, and
when the function has been disabled, it is displayed in red.
Cmp.Bal
Displayed is the number of components remaining in the feeder.
PCB.Bal
The No. of PCBs where the components can be placed before a component shortage occurs,
is displayed in these data boxes.
Each button-shaped item has a button function.
When each button is pressed, the corresponding items are re-arranged in the ascending order.
[3] Component type
Displayed are the following component data.
Comp Type / Comp Size (X, Y)
[4] Tape Type
Displayed are the following Tape data.
Tape Width / Pitch
Note