EUKYX-199-2100_G5S2_Instruction_Vol2_E - 第86页
EUKYX 1-36 199-2100 4.2 "Opr.Mode" T ab Sheet [ 3 ] “Comp Drop detection function ” Group Box The set ting v al ue varies dependin g on the head typ e. ► High-speed fle xible Head Monitor the component pi ckup …

EUKYX
1-35199-2100
[1] "Remaining comp on Nzl check after plcmnt" Group Box
This function is used to check if no foreign object or component adheres to the nozzle end before
the nozzle picks up a component.
When a foreign object or a component is detected, an "ERROR" window opens and the machine
stops running after it has taken an abandoning action.
►
Head 1, Head 2
Disable
When this button is selected, the pre-pick nozzle confirmation function is not activated.
Enable
When this button is selected, the pre-pick nozzle confirmation function is activated.
►
Borderline
This button makes it possible to determine the judgement level for the pre-pick nozzle confirmation
function.
Mode
Select the mode for Borderline from "Manual" or "Auto".
Data
Specify the set value for the Borderline when "Manual" is selected for Mode.
[2] "Comp Discard Mode" Group Box
Specify the timing to abandon the components.
►
Abandon Seq Sel
Aft Plcm
When this button is selected, the machine abandons the components that were left behind (not
placed) after it has placed the picked component on the PCB.
Bfr Plcm
When this button is selected, the machine abandons the components that cannot be placed before
it places the picked component on the PCB.
In normal cases, it is recommended that the [Bfr Plcm] button be selected. For the stage on
which the coplanarity unit (option) is installed, be sure to select the [Aft Plcm] button.
Blow Count
Specify the number of blowing times.
Blow time
Specify the period of time during which air should be blown.
Discard opn at comp missing
Select “Enable” or “Disable” for the component discarding movement when the component is
missing.
Notice
4.2 "Opr.Mode" Tab Sheet

EUKYX
1-36199-2100
4.2 "Opr.Mode" Tab Sheet
[3] “Comp Drop detection function” Group Box
The setting value varies depending on the head type.
►
High-speed flexible Head
Monitor the component pickup status when mounting.
Detect the component drop or vertical component.
Select “Disable“, “Enable (Auto)“, “Pass“, “1 Time“, or “Just Before“.
Disable
When this button is selected, the Comp Drop detection function is not used.
Enable (Auto)
When this button is selected, the Comp Drop detection function is used.
The pickup status is checked only when the picked component passes over the sensor position
when mounting.
Pass
When this button is selected, the Comp Drop detection function is used.
The pickup status is checked only when the picked component passes over the sensor position
when mounting.
1 Time
When this button is selected, the Comp Drop detection function is used.
The pickup status is checked at least 1 time when mounting.
Just Before
When this button is selected, the Comp Drop detection function is used.
The pickup status is checked by passing the picked component over the sensor position just before
mounting the component.
(a) The component drop is detected only with a high-speed nozzle.
Additionally, The component drop is not detected depending on the component shape or
material.
(b) The component drop setting on the component library has priority.
Note

EUKYX
1-37199-2100
►
High-speed flexible Head
Detect the component drop by monitoring the vacuum flow rate from the head when mounting.
Select “Disable“, “Enable (Auto)“, “Enable (Notice)“, or “Enable (Stop)“.
Disable
When this button is selected, the Comp Drop detection function is not used.
Enable (Auto)
When this button is selected, the Comp Drop detection function is used.
No information is reported when the vacuum flow rate from the head is abnormal value when
mounting a component normally.
Enable (Notice)
When this button is selected, the Comp Drop detection function is used.
The information is reported on the machine information when the vacuum flow rate from the head
is abnormal value when mounting a component normally.
Enable (Stop)
When this button is selected, the Comp Drop detection function is used.
The information is reported on the machine information and the operation is stopped when the
vacuum flow rate from the head is abnormal value when mounting a component normally.
(a) The component drop is not detected for the component that the vacuum flow rate from
the head is abnormal value when mounting the component normally.
(b) The component drop is not detected for the nozzle that the vacuum flow rate from the
head is not abnormal value when a component is dropping.
[4] Surplus Comp detection function
When picking up 2 or more components set as “Square“ in the Component Library, this
function detects them as the recognition error.
Disable
When selected, Surplus Comp detection function is not used.
Enable
When selected, Surplus Comp detection function is used.
[5] [ ]/[ ] Page change buttons
Changes the page of “Comp Handling“ window.
[6] Remaining comp on Nzl check after plcmnt
Setting the button which is displayed under each nozzle in the Head 1 or 2, to “OFF”, cancels the
nozzle check before the component pick-up operation for each nozzle.
ON : The nozzle check before pick-up operation is to be performed.
OFF : The nozzle check before pick-up operation is not to be performed.
Setting it to “OFF” for the nozzles with larger diameter, prevents a malfunction such as a
machine stop in such case that solder debris, etc., attached to the nozzle, is judged as a
component taken back by the nozzle.
Note
Note
4.2 "Opr.Mode" Tab Sheet