EUKYX-199-2100_G5S2_Instruction_Vol2_E - 第91页

EUKYX 1-41 199-2100 [ 3] Fdr Fiducial Recog Enable : It is sel ecte d when the Feede r Fi duc ia l Recogniti on is used. Disable: It is sel ecte d when the Feede r Fi duc ia l Recogniti on is not used. [ 4] Fdr In / Out …

100%1 / 327
EUKYX
1-40199-2100
4.2.6 Feeder
The following window appears by pressing the [Feeder] button on the “Opr. Mode“ tab sheet.
[1]
[4]
[2]
[3]
[5]
[6]
F2A32A
[1] Pickup Auto Adjust
This function is used to correct the feeder offset data through statistical processing of the difference
between the nozzle and component center positions calculated during component recognition
according to the parameters specified as "Auto fdr axis adj set" in the "Auto Ope. Set-up" tab sheet
in the "System" window.
The [Enable] or the [Disable] button can be selected for the pickup auto adjust mode.
Each button can be selected separately for the X and Y directions.
The "Auto Ope. Set-up" tab appears when the [Ope. Palam.] button is pressed after pressing
the [Sys. Setting] button on the common menu bar.
(X) Dir
Enable:
Select this button to use the automatic feeder axis adjustment function for the X direction.
Disable:
Select this button not to use the automatic feeder axis adjustment function for the X direction.
(Y) Dir
Enable:
Select this button to use the automatic feeder axis adjustment function for the Y direction.
Disable:
Select this button not to use the automatic feeder axis adjustment function for the Y direction.
(a) In normal cases, the [Enable] button should be selected.
(b) The designation of the pickup auto adjust function for a specific feeder can be canceled
in the component library data.
(c) When the machine is set in the “RUN” or the “WAIT” mode, the data save operation
(saving of changed settings) cannot be performed.
[2] Height data in Fdr
Enable:
Select this button to use the feeder height data when components are picked up.
Disable:
Select this button not to use the feeder height data when components are picked up.
Note
Note
4.2 "Opr.Mode" Tab Sheet
EUKYX
1-41199-2100
[3] Fdr Fiducial Recog
Enable:
It is selected when the Feeder Fiducial Recognition is used.
Disable:
It is selected when the Feeder Fiducial Recognition is not used.
[4] Fdr In/Out
"Enable" or "Disable" can be selected to determine whether or not the feeder offset (B) data should
be cleared automatically when the feeder is installed or uninstalled.
Fdr Offset (B) Auto Clear
Disable
Select this button not to clear the feeder offset (B) data automatically when the feeder is installed or
uninstalled.
Enable
Select this button to clear the feeder offset (B) data automatically when the feeder is installed or
uninstalled.
[5] Start with installed Fdr only
Disable
When pressed, automatic operation with installed feeder only is available.
Enable
When pressed, automatic operation with installed feeder only is disabled.
[6] In-use Fdr in/out
Disable
This button is selected when the "in-use feeder in/out" function is not used.
Enable
This button is selected when "in-use feeder in/out" function is used.
4.2 "Opr.Mode" Tab Sheet
EUKYX
1-42199-2100
4.2.7 Tape Pocket Recog
When the [Tape Pocket Recog] button is pressed on the "Operation Mode" tab sheet, the following
window appears.
This function recognizes the pocket edge section, finds the pocket center and feedbacks the result
to the feeder offset (B) value.
[15]
[6]
[2]
[3]
[4]
[5]
[8]
[9]
[10]
[11]
[7]
[1]
[12]
[13]
[14]
F2A33A
(a) This function can be used for the components (size: 2012 or less) packaged in a paper
tape.
(b) In the case that the actual component size is out of the range of ±25% of the component
size set in the component library, the "Machine Information" window appears.
Note
4.2 "Opr.Mode" Tab Sheet