4.2.9 Data
When the [Data] button is pressed on the "Opr. Mode" tab sheet, the following window appears.
[2]
[1]
F2A36A
[1] Temp Comp Lib Save Mode
One of the following options can be selected for saving the carrier data.
[Standard] Button
When selected, the data saving operation continues only when the component data is
perfectly consistent.
(Standard)
(Before Changeover)
101 AAA
102 BBB
103 CCC
104 DDD
(After Changeover)
All are initialized because
there is a difference in 102.
101 AAA
102 DDD
103 CCC
104 DDD
Initialized
Initialized
Initialized
Initialized
Simplified Packaging
Direction Change Function
F2A37
[Continuation 1] Button
The system keeps on saving only the component data that has the same ID.
(Continuation 1)
(Before Changeover)
101 AAA
102 BBB
103 CCC
104 DDD
(After Changeover)
The 102 data is initialized as
there is a difference.
The 104 data is cleared as
it is not used.
The other data are continued.
101 AAA
102 DDD
103 CCC
104
Continued
Initialized
Continued
Cleared
Simplified Packaging
Direction Change Function
F2A38
4.2 "Opr.Mode" Tab Sheet

EUKYX
1-49199-2100
Continuation 2
The system keeps on saving the data when the component data has the same ID and is not
used.
(Continuation 2)
(Before Changeover)
101 AAA
102 BBB
103 CCC
104 DDD
(After Changeover)
The 102 data is initialized as
there is a difference.
The 104 data is sustained as
it is not used.
The other data are continued.
101 AAA
102 DDD
103 CCC
104
Continued
Initialized
Continued
Continued
Edited Data
F2A39
[2] Temp Comp Lib Edit Mode
The changing method for the edited data is selected in this text box.
Standard
The edited data is maintained.
Comp Lib Priority
When selected, this button initializes the pieces of data having the changed IDs to be those
in the component library data.
4.2 "Opr.Mode" Tab Sheet

EUKYX
1-50199-2100
4.2.10 Noz Blow
This function
prevents the nozzle clogging. This function can extend the nozzle maintenance
interval. When the [Noz Blow] button is pressed on the "Opr. Mode" tab sheet, the following
window appears.
[2]
[1]
[4]
[3]
[5]
Graphic
Development
F2A40A
[1] Head 1, Head 2
Disable
When this button is selected, the nozzle air blowing function is not activated.
Enable
When this button is selected, the nozzle air blowing function is activated.
[2] Effective only under "WAIT"
Disable
The nozzle air blowing function is used during the Machine (STANDBY) mode.
Enable
The nozzle air blowing function is used based on the set timing.
[3] Execution Timing
Specify the timing to execute the air blowing.
Operation time
Select this button to specify the timing of the execution based on the running time.
PCB Count
Select this button to specify the timing of the execution based on the number of PCBs.
[4] Count
The set value is designated based on the item selected in executive timing.
When the [Run Time] is selected, the interval from the automatic operation start to the air blow
execution is set based on time.
When the [PCB Counter] is selected, the interval from the automatic operation start to the air blow
execution is set based on the completed number of PCBs.
[5] [Blow Count] Button
Specify the number of blowing times.