m220_383_02_process_manual工艺手册 - 第61页

PROCESS DESCRIPTION P ROCESS M ANU AL 4.3-8 116 Gas O2 [2] at 0 [SCCM] Variable Command: No 117 Gas SIH4 [3] at 0.0 [SCCM] Variable Command: No 118 Gas PRESSURE [8] at 0 [MTOR] Variable Command: No 119 Digital out N2 PUR…

100%1 / 91
PROCESS DESCRIPTION
P
ROCESS MANUAL
4.3-7
74 Alarm limit setting for Gas O2 [2] at 10 % ( ± 50 SCCM) Variable Command: No
75 Branch on gas/pressure O2 [2] to step O2 PURGE. Sonalert alarm Yes
76 13 DEPOSITION
77 Message DEPOSITION [13]. Sonalert alarm No
78 Time: [000:30:00] (hr:min:sec) Variable Command: Yes
79 Gas [SIH4 [3]] at [50.0] [SCCM] Variable Command: Yes
80 Alarm limit setting for Gas SIH4 [3] at 10 % ( ± 10.0 SCCM) Variable Command:
No
81 Alarm limit setting for Gas PRESSURE [8] at 5 % ( ± 100 MTOR) Variable
Command: No
82 Branch on gas/pressure O2 [2] to step O2 PURGE. Sonalert alarm Yes
83 Branch on gas/pressure SIH4 [3] to step O2 PURGE. Sonalert alarm Yes
84 Branch on gas/pressure PRESSURE [8] to step O2 PURGE. Sonalert alarm Yes
85 14 O2 PURGE
86 Message PURGE [12]. Sonalert alarm No
87 Time: 000:02:00 (hr:min:sec) Variable Command: No
88 Gas N2 [1] at 0.00 [SLM] Variable Command: No
89 Gas SIH4 [3] at 0.0 [SCCM] Variable Command: No
90 Gas PRESSURE [8] at 0 [MTOR] Variable Command: No
91 Digital out N2 PURGE[9] = OFF,N2PROCES[10] = ON,PROCESS[11] =
ON,EVACSIH4[12] = OFF,,,SOFTSTRT[15] = ON,MAINVAC[16] = ON
Variable Command: No
92 Alarm limit setting for Gas SIH4 [3] at 0 % ( ± 0.0 SCCM) Variable Command: No
93 Alarm limit setting for Gas PRESSURE [8] at 0 % ( ± 0 MTOR) Variable Command:
No
94 15 EVACUATE
95 Message EVACUATE 3 [10]. Sonalert alarm No
96 Time: 000:05:00 (hr:min:sec) Variable Command: No
97 Gas O2 [2] at 0 [SCCM] Variable Command: No
98 Alarm limit setting for Gas O2 [2] at 0 % ( ± 0 SCCM) Variable Command: No
99 16 PURGE
100 Message PURGE [12]. Sonalert alarm No
101 Time: 000:05:00 (hr:min:sec) Variable Command: No
102 Digital out N2 PURGE[9] = ON,N2PROCES[10] = ON,PROCESS[11] =
ON,EVACSIH4[12] = OFF,,,SOFTSTRT[15] = ON,MAINVAC[16] = ON
Variable Command: No
103 17 EVACUATE
104 Message EVACUATE 3 [10]. Sonalert alarm No
105 Time: 000:05:00 (hr:min:sec) Variable Command: No
106 Digital out N2 PURGE[9] = OFF,N2PROCES[10] = ON,PROCESS[11] =
ON,EVACSIH4[12] = OFF,,,SOFTSTRT[15] = ON,MAINVAC[16] = ON
Variable Command: No
107 18 READY
108 Message STANDBY [1]. Sonalert alarm No
109 Digital out N2 PURGE[9] = ON,N2PROCES[10] = ON,PROCESS[11] =
ON,EVACSIH4[12] = OFF,,,SOFTSTRT[15] = OFF,MAINVAC[16] = ON
Variable Command: No
110 Wait for operator
111 19 BACKFILL 1
112 Message BACKFILL [14]. Sonalert alarm No
113 Time: 000:01:00 (hr:min:sec) Variable Command: No
114 Boat to 2000.0 mm at 300.0 mm/min with oscillation speed of 0.0 mm/min.
Variable Command: No
115 Gas N2 [1] at 0.00 [SLM] Variable Command: No
PROCESS DESCRIPTION
P
ROCESS MANUAL
4.3-8
116 Gas O2 [2] at 0 [SCCM] Variable Command: No
117 Gas SIH4 [3] at 0.0 [SCCM] Variable Command: No
118 Gas PRESSURE [8] at 0 [MTOR] Variable Command: No
119 Digital out N2 PURGE[9] = ON,N2PROCES[10] = ON,PROCESS[11] =
ON,EVACSIH4[12] = OFF,,,SOFTSTRT[15] = ON,MAINVAC[16] = OFF
Variable Command: No
120 Alarm on digital in PRESS N2[1] = ON,PRESSAIR[2] = ON,doorclsd[3] =
ON,VACFAIL[4] = OFF,,,TEMP SCR[7] = ON,EXCESS[8] = ON
121 Abort recipe 08
122 20 BACKFILL 2
123 Message BACKFILL [14]. Sonalert alarm No
124 Time: 000:10:00 (hr:min:sec) Variable Command: No
125 Gas N2 [1] at 10.00 [SLM] Variable Command: No
126 Digital out N2 PURGE[9] = ON,N2PROCES[10] = ON,PROCESS[11] =
ON,EVACSIH4[12] = OFF,,,SOFTSTRT[15] = OFF,MAINVAC[16] = OFF
Variable Command: No
127 END
4.3.8
Troubleshooting an LTO process
Problem: Cause: Solution:
Wafers are thick at the door side
and thin at the pump side.
Temperature ramp is not
correct.
Injector design is not optimal
Insufficient N
2
carrier gas
Increase temperature ramp
(door side temperature lower
then pump side temperature).
Use different injector design
Increase N
2
carrier gas
Wafers are thick at the pump side
and thin at the door side.
Temperature ramp is not
correct.
Injector design is not optimal
Too much N
2
carrier gas
Reduce temperature ramp
(door side temperature higher
then pump side temperature).
Use different injector design
Reduce N
2
carrier gas
Wafers are thick at the top and
thin at the bottom.
Wafers are not aligned
parallel.
Place wafers parallel and flat
side at the top
Wafers are thick at the edges and
thin at the center.
Wafers are placed too close
together
Cage design is not optimal
Place wafers further apart
Use different cage design
No consistency in uniformity.
Dirty quartz ware or wafers.
No constant pressure control.
Draft along the furnace.
Clean tube, quartz ware and
paddle.
Use clean wafers.
Check pressure control.
Close possible draft holes.
Layer is too thin cross load.
Deposition time is too short. Increase deposition time in
recipe.
Layer is too thick cross load
Deposition time is too long. Decrease deposition time in
recipe.
OPERATION INSTRUCTIONS
P
ROCESS MANUAL
5.Operation Instructions
This document describes the various procedures required for a process engineer. The
procedures describe all information according to the process engineers.
5.1 Load or Unload process wafers
Loading and unloading process wafers on the paddle is required before and after each process
run.
5.1.1
Load process wafers
Place the wafers on the wafer carriers, depending on the situation with (vacuum)
tweezers or a wafer transfer system.
Pick-up wafer carriers with a pick-up fork or automated loading tool.
Place the wafer carriers around the center of flatzone as indicated on the
loadstation.
5.1.2 Unload wafers
CAUTION
Wafers and paddle are hot.
Allow the wafers to cool down.
Pick-up wafer carriers with a pick-up fork or automated loading tool. (Amtech
Systems S300)
Remove the wafers from the wafer carriers, depending on the situation with
(vacuum) tweezers or a wafer transfer system.
5.1-1