00198352-01_AI_Conveyor_Conversion_Kit_E-by-SIPLACE_EN - 第16页

2 Conversion 2.3 Steps and procedure Assembly Instructions E by SIPLACE Conveyor Conversion Kit 03/2017 16 Fig.6: Dip switch for left and right fixed conveyor 1 Picture of left fixed conveyor TSP400 dip switch setting →…

100%1 / 32
Assembly Instructions E by SIPLACE
Conveyor Conversion Kit 03/2017
2 Conversion
2.3 Steps and procedure
15
Fig.5: Connectors on TSP
Unplug the connectors (1) from TSP.
2 Conversion
2.3 Steps and procedure
Assembly Instructions E by SIPLACE
Conveyor Conversion Kit 03/2017
16
Fig.6: Dip switch for left and right fixed conveyor
1 Picture of left fixed conveyor TSP400
dip switch setting
→ set pin 2, 6 and 8 ON
2 Picture of right fixed conveyor TSP400
dip switch setting
→ set pin 6 and 8 ON
CAUTION
Important Setting!
Set the dip switch for your conveyor type.
Assembly Instructions E by SIPLACE
Conveyor Conversion Kit 03/2017
2 Conversion
2.3 Steps and procedure
17
Fig.7: Stopper rail screws
Remove the cable ties that fix the stopper rail cables.
Remove the stopper rail screws (1).