00195963-03_MM SWS-EN - 第61页

61  Turn Segm ent 1 from Flip Unit to Top pos ition and co ver the Nozz letip or t he Suction Plate .  Change t o Menu Manu al op erations IO s [1] and cho ose folder Flipper and Die A ttach [2] ( see scre enshot below…

100%1 / 79
Change from previous screenshot into Manual operations -> Manual operations
subsystems -> IOs -> Manual operations USBIO -> USB programs [1] and read out the
main vacuum value Main Vacuum [mbar] (see screenshot below).
Take care, that the Vacuumpump is Switched Off, like in the Screenshot below..
The Main Vacuum Value should have at least 700 mbar. See Screenshot above.
Write down this value.
Change to Menu Manual operations [1] -> Manual operations subsystems [2] -> IOs [3]
(see screenshot below)
61
Turn Segment 1 from Flip Unit to Top position and cover the Nozzletip or the Suction Plate.
Change to Menu Manual operations IOs [1] and choose folder Flipper and Die Attach [2]
(see screenshot below).
Use button [3] to switch on the Vacuum D02 Segment 1 Vacuum (see below). The Vacuum
must be recognized at the Nozzletip or the Suction Plate.
Beside this Button, under AI1 Vacuum sensor segment 1” the vacuum value can be read out.
This Value should be nearly the same like the previously noticed Main vacuum value. If this value is
lower, there is some vacuum leakage and all the tubings and seals (e.g. Vacuum plate) must be
controlled and exchanged in case.
The procedure for Segment 2 is similar to Segment 1:
Turn Segment 2 from Flip Unit to Tip positionand cover the Nozzletip or the Suction Plate.
Change to Menu Manual operations IOs [1] and choose folder Flipper and Die Attach [2]
(see screeshot below).
Use button [3] to switch on the Vacuum D04 Segment 2 Vacuum (see below). The Vacuum
must be recognized at the Nozzletip or the Suction Plate.
Beside this Button, under AI2 Vacuum sensor segment 2” the vacuum value can be read out.
This Value should be nearly the same like the previously noticed Main vacuum value. If this value is
lower, there is some vacuum leakage and all the tubings and seals (e.g. Vacuum plate) must be
controlled and exchanged in case.