00195963-03_MM SWS-EN - 第64页

Legende: [1] Reject bin for ch ips [2] Magnetic contact s urface [3] Sensor  Empty the r eject bi n  Clean th e underside o ft he bin and the ma gnetic cont act s urfaces with a lint free c loth. All surfaces must be f…

100%1 / 79
63
Checking the Suction Plates at the Nozzle Take-Up for Leaks
Interval: 3 months
Equipment: New suction plates, if necessary
Legend
[1] Suction plate
[2] Nozzle
Remove the nozzles from both segments.
Check the blue suction plate for signs of
damage or wear.
If it shows signs of damage, it has to be
changed for a new one.
Loosen the screw thread of the suction plate and lift off the suction plate.
Make sure, that the spacer remains in its position. Otherwise the tightness is not ensured.
Position the suction plate straight, otherwise there is danger of damaging the screw thread.
Fasten the suction plate with a torque of 13 Ncm.
Re-insert the nozzles.
Check reject bins
Interval: 3 month
Equipment: Lint-free cloth
The Reject bin types may be different depending on the SWS-Version.
Reject bin with no Die-Attach-Unit installed Reject bin with installed Die-Attach
Legende:
[1] Reject bin for chips
[2] Magnetic contact surface
[3] Sensor
Empty the reject bin
Clean the underside oft he bin and the magnetic contact surfaces with a lint free cloth. All
surfaces must be free of dirt, to ensure the correct positioning of the reject bin.
Clean the sensor with a lint free cloth.
Lubricating the Linear Guides from Rotary Part
Interval: 4 months
Equipment:
Multipette, Lubcon Thermoplex ALN 1001/00D
CAUTION
Be especially careful, when lubricating the linear guide.
No lubricant must get onto the reading unit.
Linear guide at the rotary part
Legend
[1] Linear guide
Fill the Multipette (See ”Filling and Setting the Multipette” on page - 18.).
Apply 4µl lubricant onto the Z axis.
Manually move the Z axis up and down for approx. 5 times.
Apply another 4µl lubricant.
Manually move the Z axis up and down for another 5 times.
Remove excess lubricant with a lint-free cloth.
65
Checking Connected Cables and Lines
Interval: Yearly
Equipment: 00385451-01 FPC Flex Cable Jumper 5Pol Length=2,2 (Inch) (Servicbox)
Legend
[1] Connection points of the vacuum lines
[2] Cable for touch down sensor
[3] Flat ribbon cable
Check the cables and lines connected to
the rotary part for secure position and
signs of wear or rubbing.
In case, replace the cable 00385451-01
Make sure, that the flat ribbon cable has an
appropriate radius, to prevent it from being
buckled.
Check the cables and lines that come out
of the rear side of the hollow shaft motor for
secure position and signs of wear or rub-
bing.
No objects or anything else must lie
against the surface of the moving calbes
(hoses).