00195963-03_MM SWS-EN - 第66页
M ain ten ance Wo rk at the Gripper Cleaning the G ripper Jaws Interval: Weekly Equipment: Ethyl alcoho l, cleaning buds , lint - free Legend [1] Gripper jaws [2] Guid e rail Clean th e gripper j aws with a c leaning b…

65
Checking Connected Cables and Lines
Interval: Yearly
Equipment: 00385451-01 FPC Flex Cable Jumper 5Pol Length=2,2 (Inch) (Servicbox)
Legend
[1] Connection points of the vacuum lines
[2] Cable for touch down sensor
[3] Flat ribbon cable
Check the cables and lines connected to
the rotary part for secure position and
signs of wear or rubbing.
In case, replace the cable 00385451-01
Make sure, that the flat ribbon cable has an
appropriate radius, to prevent it from being
buckled.
Check the cables and lines that come out
of the rear side of the hollow shaft motor for
secure position and signs of wear or rub-
bing.
No objects or anything else must lie
against the surface of the moving calbes
(hoses).

Maintenance Work at the Gripper
Cleaning the Gripper Jaws
Interval: Weekly
Equipment:
Ethyl alcohol, cleaning buds, lint-free
Legend
[1] Gripper jaws
[2] Guide rail
Clean the gripper jaws with a cleaning bud
moistened with ethyl alcohol.
Cleaning the Guide Rail
NOTE
The guide rail of the gripper has got a lifetime lubrication, so that it is only necessary to clean it.
Interval: 1 month
Equipment:
SIPLACE cleaning tissue
Wipe the guide rail of the gripper with a SIPLACE cleaning tissue.

67
Lubricating Bearings and Driver Groove at the Sensor Lever
Interval: 1 month
Equipment:
Spray grease (aerosol)
Legend
[1] Bearing of the sensor lever with
driver groove behind it
[2] Return spring
Carefully, lubricate the bearing of the sen-
sor lever at the spring suspension.
In doing so, the driver groove is lubricated
at the same time.
Remove any excess lubrication.
Control the return spring for damage.
Lubricating or Cleaning the Z Guide
Depending on the gripper version (for left or right location) the Z guide consists of a sliding guide
with springs (right location) or of a linear carriage with springs (left location).
Interval: 1 month
Equipment:
Multipette, Lubcon Thermoplex ALN 1001/00 (left location)
SIPLACE cleaning tissue (right location)
Gripper - Z guide at left location Gripper - Z guide at right location
Legend
[1] Linear carriage [2] Sliding guide
1