Printer 710_810 v8 Preventive Maintenance - 第45页

PREVENTI VE MAINTENA NCE MONTH LY MAINTE NANC E Chapter Issue 6 Oct 06 Technical Reference Manual 33.45 Monthly Har dware Check General Mai ntenance Tick Chec k the c ond iti on of t he boa rd c lamps. Cycle the board cl…

100%1 / 70
PREVENTIVE MAINTENANCE
MONTHLY MAINTENANCE
33.44 Technical Reference Manual Chapter Issue 6 Oct 06
Month December Maintenance Procedure
SPC Alignment
Check and Machine
Cycle Count
Fill out details: SPC Alignment Check and Machine Cycle Count at the start of
this section.
Software
Monthly Maintenance
Software Check Record Tick
Check the date and time settings.
Check the software loaded and options.
Check the software version is the latest issue.
View Event Log Tick
Check for initialisation errors.
Check for screen position errors (31210, 31211, 31212).
Check for camera errors (31207, 31208).
Under Screen Cleaner (USC) (if fitted) Tick
Check that the paper feed mechanism operates correctly (Blue and Cyclone).
Check the oscillation motor moves the cleaner mechanism back and forth (Cyclone and Vortex).
Check the condition of the squeegee blades (Blue).
Check that the cleaner mechanism raises and lowers smoothly.
Check the screen cleaner height.
Check that the solvent dispenses and it is at a suitable pressure.
Check that solvent dispenses evenly across the paper or cassette.
Check the condition of all hoses and connections.
Check the correct operation of the vacuum filtration unit.
Perform a USC cycle and confirm correct operation.
Environmental Control Module (if fitted) Tick
Inspect the air filters clean/replace (as detailed in the equipment manual).
Check for leakage in the system.
Check the system holds the temperature (as described in the equipment manual).
PREVENTIVE MAINTENANCE
MONTHLY MAINTENANCE
Chapter Issue 6 Oct 06 Technical Reference Manual 33.45
Monthly Hardware Check
General Maintenance Tick
Check the condition of the board clamps.
Cycle the board clamps ensure that clamping and release is smooth.
Cycle the Test 265test 1 board on the transport rails ensure smooth operation.
Clean the table top of paste and debris, apply a wipe of light oil.
Clean the transport rails of paste and debris.
Inspect tooling pins/assemblies/modules for wear, replace any formflex tooling modules leaking excessively.
Inspect the air filters and clean/recommend replacement.
Screen Alignment Tick
Inspect the wiring and connections.
Inspect the three striker plates, clean and apply a wipe of light grease.
Check the actuator fixed ball at the end of the actuator shaft is clean.
Check all actuators home correctly.
Screen Change Tick
Remove and clean the auto drip tray.
Fully extend the auto drip tray telescopic plungers and clean.
Clean the screen stop actuator arm lever.
Clean the screen at stop sensor.
Refit the auto drip tray and check operation of the screen change mechanism.
Chase Tick
Inspect the condition of wiring/pneumatic connections.
Check operation of the chase clamps.
Clean and lubricate with light oil, the omni track bearings and the underside of the track plates.
Clean the left and right screen at centre optos.
Clean the stencil guide strips of debris/paste.
Check operation of the ASM.
PREVENTIVE MAINTENANCE
MONTHLY MAINTENANCE
33.46 Technical Reference Manual Chapter Issue 6 Oct 06
Summary/Remarks
Signed: Date: