00198460-01_DC_SIPLACE_TX-EditionV2_DE EN - 第20页
electric_schematic SIPLACE TX_V2 electric_schematic SIPLACE TX_V2 electric_schematic SIPLACE TX_V2 electric_schematic SIPLACE TX_V2 90012669-010501LE3 Replaced by Overview TX Overview TX Overview TX Overview TX Protectio…

electric_schematic SIPLACE TX_V2
electric_schematic SIPLACE TX_V2
electric_schematic SIPLACE TX_V2
electric_schematic SIPLACE TX_V2
90012669-010501LE3
Replaced by
Power unit
Power unit
Power unit
Power unit
Overview
Ov
erview
Overview
Overview
Replaced by
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und
Mitteilung des Inhalts nicht gestattet, soweit nicht ausdrücklich zugestanden.
Proprietary Data, company confidential.
All rights reserved
Copying of this document, giving it to others and the use or
communication of the contents thereof, are forbidden without express authority.
Doc. No.
00 01 02 03 04 05 06 07 08 09
Privileged business information.
Do not release
Offenders are liable to payment of damages. All rights are reserved in the
event of the grant or the registration of a utility model or design.
Zuwiederhandlungen verpflichten zu Schadenersatz. Alle Rechte vorbehalten,
insbesondere für den Fall der Patenterteilung oder GM-Eintragung vorbehalten.
Page:
Function: Overview
==OV=TX+03146155/14
drawing number:
03146155-010701LE3
Main Power E-insert
Main P
ower E-insert
Main Power E-insert
Main Power E-insert
GmbH & Co KG
ASM
Assembly Systems
Copyright reserved
Ed.
Original
Pingist
Date
Date
Modification
Appr
07.02.2018
Name
Size DIN A2
Sheet
14
/
1
Serialize digital inputs
Data bus level separation done by optocouplers
Signal level: 24 V unipolar
RED: individual voltage monitoring (on Board)
RS485
driver
CLKSDATACS
32 bits
GREEN: Diagnostic OK
. . . . .
. . . . .
. . . . .
. . . . .
Power Module ME 03146155-
Power Module ME 03146155-
Power Module ME 03146155-
Power Module ME 03146155-
3Ph/Mot1
Gantry-1/X
3Ph/Mot2
Gantry-1/Y
3Ph/Mot3
Gantry-2/X
3Ph/Mot4
Gantry-2/Y
42V FELV supply
SAFETY-
S
AFETY-
SAFETY-
SAFETY-
CONTROL
CONTROL
CONTROL
CONTROL
Voltage testing terminal
V
oltage testing terminal
Voltage testing terminal
Voltage testing terminal
Use for testing purpose only!
Use for testing purpose only!
Use for testing purpose only!
Use for testing purpose only!
42V_FELV
24V_MGCU
42V_buff1
24V_buff1
42V_buff2
24V_buff2
- not used -
F1
F3
F4
F5
F6
F7
F10
F11
F12
F13
F14
F15
F16
F21
Shuttle drives 42V
Shuttle & Service 24V
Distributor 24V
Monitor/CIN 24V
MGCU supply (42V --> 25V)
Conveyor Control 24V
[SMD] Internal supply 24V
CSB Signal 24 V
CSB supply 24V Safety
[SMD] Diagnostic supply 24V
Gantry1 supply 42V --> 25V
Gantry2 supply 42V --> 25V
Conveyor drives 42V
42V (-X8 PELV, not-used)
Fuses Board FD.A1
Fuses B
oard FD.A1
Fuses Board FD.A1
Fuses Board FD.A1
-F1
-F2
-F4
-F21
-PS4
-PS4
-PS4
-PS4
PULS.QT40-999-70
Converter AC3~ 380-415 V/DC300 and 160 V; 1,2kW
03103087
==ME/43.01
L1/L2/L3/PE
-CAP1
-CAP1
-CAP1
-CAP1
PULS.PCS417.381
Capacitor unit 38 mF including diagnostic master
03103081
==ME/43.01
Cable power PS4 to CAP TX V2
03151243
03151243
03151243
03151243
-W4
-
W4
-W4
-W4
-PS3
-PS3
-PS3
-PS3
DC 42V / FELV
Uout=36-42V / 480W
PULS.QT20.361
03076588
==ME/45.01
Adjust to 42 V +/- 0,5 V
Adjust to 42 V +/- 0,5 V
Adjust to 42 V +/- 0,5 V
Adjust to 42 V +/- 0,5 V
3AC 380-480V
Diagnostic connection PS1
5V/Data
03148736
03148736
03148736
03148736
-W5
-
W5
-W5
-W5
-PS2
-PS2
-PS2
-PS2
DC 42V / PELV
Uout=36-42V / 480W
PULS.QT20.361
03076588
==ME/45.02
Adjust to 42 V +/- 0,5 V
Adjust to 42 V +/- 0,5 V
Adjust to 42 V +/- 0,5 V
Adjust to 42 V +/- 0,5 V
3AC 380-480V
-FD.A1
-FD
.A1
-FD.A1
-FD.A1
Fuse- and Distribution
Fuse- and Distribution
Fuse- and Distribution
Fuse- and Distribution
03136970
==ME/45.00
FD.A1 Connect
Grounding Power
03154393
03154393
03154393
03154393
-W8.1
-
W8.1
-W8.1
-W8.1
Cable
PULS module wiring TX V2
03148734
03148734
03148734
03148734
-W8
-
W8
-W8
-W8
-X2
-
X2
-X2
-X2
DC-Power out
160V/300V
-W17
-
W17
-W17
-W17
03148738
03148738
03148738
03148738
==ME/45.05
Cable connection
distributor safety
to X29.CSB
03151246
03151246
03151246
03151246
-W11.1
-
W11.1
-W11.1
-W11.1
-PS1
-PS1
-PS1
-PS1
DC 24V PELV
Uout=24-28V / 480W
PULS.QT20.241
03055232
==ME/45.03
Adjust to 24V +/- 0,2 V
Adjust to 24V +/- 0,2 V
Adjust to 24V +/- 0,2 V
Adjust to 24V +/- 0,2 V
3AC 380-480V
-X2.CAP1
-
X2.CAP1
-X2.CAP1
-X2.CAP1
Cable DC Power CAP1
03151245
03151245
03151245
03151245
-W6
-
W6
-W6
-W6
-X304
-
X304
-X304
-X304
Voltage testing terminal
DC 300V
==ME/43.04
LV Connection CSB to FD.A1
03148745
03148745
03148745
03148745
-W10
-
W10
-W10
-W10
Cable connection
FD.A1 160V TX V2
03148744
03148744
03148744
03148744
-W9.1
-
W9.1
-W9.1
-W9.1
DC link voltage
MGCU2 TX V2
03151247
03151247
03151247
03151247
-W13
-
W13
-W13
-W13
DC Link voltage
MGCU1 TX V2
03151248
03151248
03151248
03151248
-W12
-
W12
-W12
-W12
-W23
-
W23
-W23
-W23
03147984
03147984
03147984
03147984
==CH+03147980/53.02
-W24
-
W24
-W24
-W24
03147983
03147983
03147983
03147983
==CH+03147980/53.00
-W27
-
W27
-W27
-W27
03148739
03148739
03148739
03148739
==ME/46.00
-W34
-
W34
-W34
-W34
03147985
03147985
03147985
03147985
==CH+03147980/53.03
-W33
-
W33
-W33
-W33
03147986
03147986
03147986
03147986
==CH+03147980/53.05
-PSU1-X102
-PSU1-
X102
-PSU1-X102
-PSU1-X102
Mains input
3x 400V AC
Cable connection
distributor safety
to X30.CSB
03151246
03151246
03151246
03151246
-W11.2
-W11.2
-W11.2
-W11.2
-W28
-
W28
-W28
-W28
03147981
03147981
03147981
03147981
/14.02
-W25.2
-W25.2
-W25.2
-W25.2
03147982
03147982
03147982
03147982
/14.01
+CH/16.04
-W21.2
-
W21.2
-W21.2
-W21.2
03150043
03150043
03150043
03150043
==ME/46.03
-W21.1
-
W21.1
-W21.1
-W21.1
-W26.2
-
W26.2
-W26.2
-W26.2
03147987
03147987
03147987
03147987
==CH+03147980/53.08
-W26.1
-
W26.1
-W26.1
-W26.1
-X21.DI
-
X21.DI
-X21.DI
-X21.DI
-MGCU1
-MGCU1
-MGCU1
-MGCU1
Position controller MGCU-2
Gantry 1 axis X/Y
03117531
==CH+GA/61.00
-MGCU2
-MGCU2
-MGCU2
-MGCU2
Position controller MGCU-2
Gantry 2 axis X/Y
03117531
==CH+GA/63.00
Slide
distributor
PE
-X303
-
X303
-X303
-X303
Voltage testing terminal
DC 300 V OUT
==ME/43.03
-X0
-
X0
-X0
-X0
Diagnostic
Master
-X0.CAP1
-
X0.CAP1
-X0.CAP1
-X0.CAP1
-X1.CAP1
-
X1.CAP1
-X1.CAP1
-X1.CAP1
Power
-X1
-
X1
-X1
-X1
DC-IN
160V/300V
-FDC
-FDC
-FDC
-FDC
Fuse & Distribution
Power connector panel
==CH+03147980/52.00
-X305
-
X305
-X305
-X305
Voltage testing terminal
GND
==ME/43.04
-X15
-
X15
-X15
-X15
-X16
-
X16
-X16
-X16
TCU (Option)
-CSB
-CSB
-CSB
-CSB
000.03160454
Unit Safety Breaker (CSB) V2
03112066
==ME/44.00
-K4
-K4
-K4
-K4
Precharge
160/300V
-K3
-K3
-K3
-K3
Discharge
160/300V
-K1
-K1
-K1
-K1
300/160V
Control
-K2
-K2
-K2
-K2
300/160V
Control
Power enable
FGPE
-X306
-
X306
-X306
-X306
Voltage
testing terminal
DC 160 V OUT
==ME/44.03
-X1.CIN
-X1.CIN
-X1.CIN
-X1.CIN
-W25.1
-W25.1
-W25.1
-W25.1
03147982
03147982
03147982
03147982
/14.01
+CH/16.03
-X2.PLS
-
X2.PLS
-X2.PLS
-X2.PLS
DC connector
-X2.PLS
-
X2.PLS
-X2.PLS
-X2.PLS
PULS module wiring
L1,L2,L3,PE
03148734
-W7.1
-
W7.1
-W7.1
-W7.1
PULS module wiring
L1,L2,L3,PE
03148734
-W7.4
-
W7.4
-W7.4
-W7.4
-X1.PLS
-
X1.PLS
-X1.PLS
-X1.PLS
-X1.PLS
-
X1.PLS
-X1.PLS
-X1.PLS
Mains input PLS
3x 400V AC
Cable
Mains supply PULS unit
03148735
03148735
03148735
03148735
-W10
-
W10
-W10
-W10
USE 100 or 1000
Base-T line ONLY
03148737
03148737
03148737
03148737
-W17
-
W17
-W17
-W17
-K3
-K3
-K3
-K3
Safety_Switch 42V
-K2
-K2
-K2
-K2
Safety_Switch 24V
-F20
Gantry 2
6,3A
-F19
Gantry 1
6,3A
2x 1200µF
Buffer 160 V
+ +
-F15
Gantry 2
6.3 A T
-F14
Gantry 1
6.3 A T
-F6
MGCU
Supply
6.3 A T
-W22
-W22
-W22
-W22
03147990
03147990
03147990
03147990
+03155560/12.02
/14.00
-X5
-
X5
-X5
-X5
-X5.FDC
-
X5.FDC
-X5.FDC
-X5.FDC
-X9.FDC
-
X9.FDC
-X9.FDC
-X9.FDC
-X9
-
X9
-X9
-X9
-X11.FDC
-
X11.FDC
-X11.FDC
-X11.FDC
-X11
-
X11
-X11
-X11
-X12.FDC
-
X12.FDC
-X12.FDC
-X12.FDC
-X12
-
X12
-X12
-X12
-X14.FDC
-
X14.FDC
-X14.FDC
-X14.FDC
-X14
-
X14
-X14
-X14
-X15.FDC
-
X15.FDC
-X15.FDC
-X15.FDC
-X15.S1
-X15.S1
-X15.S1
-X15.S1 -X15.S1
-X15.S1
-X15.S1
-X15.S1
-W29.1
-
W29.1
-W29.1
-W29.1
03147988
03147988
03147988
03147988
==CH+03147980/54.01
FD.A1 Connect
Grounding Power
03154393
03154393
03154393
03154393
-W8.2
-
W8.2
-W8.2
-W8.2
-X5
-
X5
-X5
-X5
27V Diagnostic
QT40-Unit FCU
-X8
-
X8
-X8
-X8
DC 24/48V
-X9
-
X9
-X9
-X9
DC 24V CIN
& Monitor
-X10
-
X10
-X10
-X10
Distributor
Power DC 24 V
-X11
-
X11
-X11
-X11
Gantry1 supply
DC 42V / 24V
-X12
-
X12
-X12
-X12
Gantry2 supply
DC 42V / 24V
-X13
-
X13
-X13
-X13
MGCU1&2 supply
-X14
-
X14
-X14
-X14
Conveyor
-X15
-
X15
-X15
-X15
Shuttle & TCU
-X2
-
X2
-X2
-X2
Diagnostic
serial interface
-XB8A
-
XB8A
-XB8A
-XB8A
Head 1 supply
-XB8B
-
XB8B
-XB8B
-XB8B
Head 2 supply
-X24B
-
X24B
-X24B
-X24B
Safety-Control
24V_S / 42V_S
-X24A
-X24A
-X24A
-X24A
Star Voltage +160V
-X26
-
X26
-X26
-X26
-X25
-
X25
-X25
-X25
-X26.FD
-
X26.FD
-X26.FD
-X26.FD
DC 24V IN
-X25.FD
-
X25.FD
-X25.FD
-X25.FD
DC 42V in
-X24B.FD
-
X24B.FD
-X24B.FD
-X24B.FD
-X24A.FD
-
X24A.FD
-X24A.FD
-X24A.FD
-X5.FD
-
X5.FD
-X5.FD
-X5.FD
-X9.FD
-
X9.FD
-X9.FD
-X9.FD
-X10.FD
-
X10.FD
-X10.FD
-X10.FD
-X11.FD
-
X11.FD
-X11.FD
-X11.FD
-X12.FD
-
X12.FD
-X12.FD
-X12.FD
-X13.FD
-
X13.FD
-X13.FD
-X13.FD
-X14.FD
-
X14.FD
-X14.FD
-X14.FD
-X15.FD
-
X15.FD
-X15.FD
-X15.FD
-X2.FD
-
X2.FD
-X2.FD
-X2.FD
-XB8A.FD
-
XB8A.FD
-XB8A.FD
-XB8A.FD
FELV_circuit
-XB8B.FD
-
XB8B.FD
-XB8B.FD
-XB8B.FD
FELV_circuit
-X8.FDC
-
X8.FDC
-X8.FDC
-X8.FDC
-X8
-
X8
-X8
-X8
-X8B
-
X8B
-X8B
-X8B
-X8A.FDC
-
X8A.FDC
-X8A.FDC
-X8A.FDC
-X8A
-
X8A
-X8A
-X8A
-X8B.FDC
-
X8B.FDC
-X8B.FDC
-X8B.FDC
-X11.DI
-
X11.DI
-X11.DI
-X11.DI
-X22.DI
-
X22.DI
-X22.DI
-X22.DI
Safety-loop
& Signals
-X24B
-
X24B
-X24B
-X24B
-X24A
-
X24A
-X24A
-X24A
-X29
-
X29
-X29
-X29
-X30
-
X30
-X30
-X30
-X21
-
X21
-X21
-X21
-X22B
-
X22B
-X22B
-X22B
-X19
-
X19
-X19
-X19
-X19.CSB
-
X19.CSB
-X19.CSB
-X19.CSB
-X24A.CSB
-
X24A.CSB
-X24A.CSB
-X24A.CSB
FELV_circuit
-X21.CSB
-
X21.CSB
-X21.CSB
-X21.CSB
FELV_circuit
-X22B.CSB
-
X22B.CSB
-X22B.CSB
-X22B.CSB
FELV_circuit
-X29.CSB
-
X29.CSB
-X29.CSB
-X29.CSB
-X30.CSB
-
X30.CSB
-X30.CSB
-X30.CSB
-X24B.CSB
-
X24B.CSB
-X24B.CSB
-X24B.CSB
-X3
-
X3
-X3
-X3
Diagnostic 1
-X2
-
X2
-X2
-X2
Diagnostic Interface
-X1
-
X1
-X1
-X1
Power DC-Out
160V/300V
-X3.CAP1
-
X3.CAP1
-X3.CAP1
-X3.CAP1
QT40 Diagnostic
-X2.PS4
-
X2.PS4
-X2.PS4
-X2.PS4
-X2.PS4
-
X2.PS4
-X2.PS4
-X2.PS4
-X1
-
X1
-X1
-X1
Supply
-X1
-
X1
-X1
-X1
Supply
-X2p
-
X2p
-X2p
-X2p
DLCV 300V
-X2p
-
X2p
-X2p
-X2p
DLCV 300V
-X1p.MGCU2 -X2p.MGCU2 -X1p.MGCU1 -X2p.MGCU1
-X11.DI
+CH/16.04
Fuse Diagnostic
serial interface
DI.Safety
Safety Loop & Signals
to Distributor
+CH/16.02
==+-MGCU1.300V
300V Power
/14.01
==+-MGCU2.300V
300V Power
/14.00
-X9.TI2
+GA/29.04
Head-supply
to Trailling interface 2
-X9.TI1
+GA/28.04
Head-supply
to Trailling interface 1
-DI.24V
+CH/16.05
Distributor DC 24 V
-X8.TI1
+GA/28.05
Trailing-Interface-1
-X4.IC1
+stCAM/26.00
+stCAM/26.04
Power IC&FC-Camera
-MON1
+CH/16.03
Power 24V(F5)
Monitor 1
-MON2
+CH/16.04
Power 24V(F5)
Monitor 2
-X8.TI2
+GA/29.05
Trailing-Interface-2
-X1p.MGCU1
GCU_supply DC 27 V
-X1p.MGCU2
/14.00
-X28.CO(A1)
-X29.CO(A1)
Conveyor DC 42/24 V
-X28.CO(A2)
-X29.CO(A2)
+CO008/36.11
==ME+03155560-Mains-Sub.1
-W3.2 (400VAC)
+03155560/12.03
==+-MGCU1.300V
300V Power
/14.08
==+-MGCU2.300V
300V Power
/14.08
==+-X1p.MGCU1
GCU_supply DC 27 V
/14.03
==+-X1p.MGCU2
GCU_supply DC 27 V
/14.04
==DI+-RS485.PSU
Diagnostic Master
Connection to I/O-CU X14
+CH/16.04
42V_FELV
Gantry
-SHU.UP
Shuttle_Upstream
extern Connection
-SHU.DO
Shuttle_Downstream
extern Connection
-MonIN.FCUS
Diagnistic PS6_27V
from FCUS
+03155560/12.02

electric_schematic SIPLACE TX_V2
electric_schematic SIPLACE TX_V2
electric_schematic SIPLACE TX_V2
electric_schematic SIPLACE TX_V2
90012669-010501LE3
Replaced by
Overview TX
Overview TX
Overview TX
Overview TX
Protection earth
Pr
otection earth
Protection earth
Protection earth
Replaced by
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und
Mitteilung des Inhalts nicht gestattet, soweit nicht ausdrücklich zugestanden.
Proprietary Data, company confidential.
All rights reserved
Copying of this document, giving it to others and the use or
communication of the contents thereof, are forbidden without express authority.
Doc. No.
00 01 02 03 04 05 06 07 08 09
Privileged business information.
Do not release
Offenders are liable to payment of damages. All rights are reserved in the
event of the grant or the registration of a utility model or design.
Zuwiederhandlungen verpflichten zu Schadenersatz. Alle Rechte vorbehalten,
insbesondere für den Fall der Patenterteilung oder GM-Eintragung vorbehalten.
Page:
Function: Overview
==OV=TX+CH/15
drawing number:
03146940-010201LE3
Protection earth
Pr
otection earth
Protection earth
Protection earth
GmbH & Co KG
ASM
Assembly Systems
Copyright reserved
Ed.
Original
Pingist
Date
Date
Modification
Appr
07.02.2018
Name
Size DIN A2
Sheet
15
/
5
Location 1
Location 1
Location 1
Location 1Location 2
Location 2
Location 2
Location 2
Main switch
Sercice_access
FCUS & Transformer
Machine Metal_Frame
Machine Metal_Fr
ame
Machine Metal_Frame
Machine Metal_Frame
Connection
-Feld 2
Connection
-Feld 1
3
~
3
~
3
~
-DIC
-FDC
Connector-
Field
3Ph/Mot4
3Ph/Mot3
3Ph/Mot2
3Ph/Mot1
PSU1 & MGCU - Unit
PSU1 & MGCU - Unit
PSU1 & MGCU - Unit
PSU1 & MGCU - Unit
-M1
-M1
-M1
-M1
Vacuumpump
V
acuumpump
Vacuumpump
Vacuumpump
Becker VX4.25
(0,75KW, 25m³/h)
3Ph 400V3Ph 200V
-X1
-
X1
-X1
-X1
Mains Connection
Mains Connection
Mains Connection
Mains Connection
CEE-connector
5-pole 6h 16A/400V
(3Ph.+N+PE)
Service Socket
230VAC(110VAC)
1/N/PE
Monitor-2
Monitor-2
Monitor-2
Monitor-2
==CH+CTRL/60.05
Monitor-1
Monitor-1
Monitor-1
Monitor-1
==CH+CTRL/60.01
-FCU
-FCU
-FCU
-FCU
Slim-FCU Location-1
Sl
im-FCU Location-1
Slim-FCU Location-1
Slim-FCU Location-1
-FCU
-FCU
-FCU
-FCU
Slim-FCU Location-2
Sl
im-FCU Location-2
Slim-FCU Location-2
Slim-FCU Location-2
Machine Metal_Frame
Cover outside
PE Cover Location 1
-W1
-
W1
-W1
-W1
4x2,5
-PE.MC_Frame
-PE.MC_Frame
-X101
-W3.1
-
W3.1
-W3.1
-W3.1
4x2,5
-X2.PE
-
X2.PE
-X2.PE
-X2.PE
Extern Connections
Extern Connections
Extern Connections
Extern Connections
PE star-point
PE star
-point
PE star-point
PE star-point
-W3.2
-
W3.2
-W3.2
-W3.2
4x2,5
PE Transformer
PE front-cover
-X1.VP
-
X1.VP
-X1.VP
-X1.VP
-X1.FC
-
X1.FC
-X1.FC
-X1.FC
-W2
-
W2
-W2
-W2
7x0,75
Trailing
T
railing
Trailing
Trailing
Interface 1&2
I
nterface 1&2
Interface 1&2
Interface 1&2
PE Trailing 1PE Trailing 2
-PSU1.PE
see Sheet:
Grounding and Earthing- PSU1
==ME+03146155/42.00
PE1,5
PE2,5
PE2,5
PE2,5
-FCU.CA
-FCU
.CA
-FCU.CA
-FCU.CA
PCBA_FCU Connection Assembly TX_V2
==03146501+FCU_CA/66.00
-FCUS
-FCUS
-FCUS
-FCUS
==ME+03153007/40.00
-X102
PE
FCU_Board
PE side cover-1
PE2,5
0,6 m
03006327
03112410
1 m
PE2,5
PE side cover-2
PE2,5
0,6 m
03006327
PE Cover_Location_2
03006327
0,6 m
PE2,5
03112410
1 m
PE2,5
03148048
2,9 m
PE2,5
03148047
3,6 m
PE2,5
==ME-X1.House
==ME-
X1.House
==ME-X1.House
==ME-X1.House
Extern PE-connection
Extern PE-connection
Extern PE-connection
Extern PE-connection
only for Frequency-Converter
responsibility at the customer
2,5 to 4 mm² GNYE
03116370
03116370
03116370
03116370
-W100
-W100
-W100
-W100
-T1
-
T1
-T1
-T1
SINAMICS V20
3AC 380-480V
1,1 kW (without Filter)
==ME+03151645/51.03
Vacuum Panel V20
V
acuum Panel V20
Vacuum Panel V20
Vacuum Panel V20
Frequency Converter
Fr
equency Converter
Frequency Converter
Frequency Converter
==ME+03151645/51.00
Option
-U1
-U1
-U1
-U1
Line-Filter
Line-Fi
lter
Line-Filter
Line-Filter
3x 480V 50/60Hz
max 3x 7A
==ME+03151645/51.01
-V1
-
V1
-V1
-V1
Discharge choke coil
==ME+03151645/51.00
-X1.VP
-
X1.VP
-X1.VP
-X1.VP
-PE
-FCUS-PS6
-FCUS-PS6
-FCUS-PS6
-FCUS-PS6
DC Out 27V/40A PELF
Control-Power FCU
==ME+03153007/40.00
Transformer
T
ransformer
Transformer
Transformer
US voltage adaption kit (Option)
US v
oltage adaption kit (Option)
US voltage adaption kit (Option)
US voltage adaption kit (Option)
3P208V/400V/5,05A
==ME+03155560/39.00
Service Testing-Point
DC 300/160 V IN/OUT
==ME+03146155/43.04
-MGCU2
-MGCU2
-MGCU2
-MGCU2
Position controller MGCU
Gantry 2 axis X/Y
==CH+GA/63.00
-MGCU1
-MGCU1
-MGCU1
-MGCU1
Position controller MGCU
Gantry 1 axis X/Y
==CH+GA/61.00
Fuse- and Distribution PCB
==ME+03146155/45.00
CAN- I/O control unit III
==ME+03147585/47.00
Service_Panel
-A2
Safety breaker
PCB Pre-/discharge assembly
-PS1
-PS1
-PS1
-PS1
DC 24V PELV
==ME+03146155/45.03
-PS4
-PS4
-PS4
-PS4
Power-supply 3AC
380-400V 1,2KW
==ME+03146155/43.01
-CAP1
-CAP1
-CAP1
-CAP1
DC 300/150
Capacitor Bank
==ME+03146155/43.01
-PS2
-PS2
-PS2
-PS2
DC 42V / PELV
==ME+03146155/45.02
-PS3
-PS3
-PS3
-PS3
DC 42V / FELV
==ME+03146155/45.01
-X102
PE Frame
PE Frame
PE Frame
-CSB
-CSB
-CSB
-CSB
DC 300/150
Capacitor Bank
==ME+03146155/44.00
Screen Flat_Cable
PE.Supplys
F&D / IOCU / MGCU
Service-access

electric_schematic SIPLACE TX_V2
electric_schematic SIPLACE TX_V2
electric_schematic SIPLACE TX_V2
electric_schematic SIPLACE TX_V2
90012669-010501LE3
Replaced by
Distributor PC & Control
Distributor PC & Control
Distributor PC & Control
Distributor PC & Control
Replaced by
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und
Mitteilung des Inhalts nicht gestattet, soweit nicht ausdrücklich zugestanden.
Proprietary Data, company confidential.
All rights reserved
Copying of this document, giving it to others and the use or
communication of the contents thereof, are forbidden without express authority.
Doc. No.
00 01 02 03 04 05 06 07 08 09
Privileged business information.
Do not release
Offenders are liable to payment of damages. All rights are reserved in the
event of the grant or the registration of a utility model or design.
Zuwiederhandlungen verpflichten zu Schadenersatz. Alle Rechte vorbehalten,
insbesondere für den Fall der Patenterteilung oder GM-Eintragung vorbehalten.
Page:
Function: Overview
==OV=TX+CH/16
drawing number:
03146940-010201LE3
Cable_Harness
Cable_Harness
Cable_Harness
Cable_Harness
GmbH & Co KG
ASM
Assembly Systems
Copyright reserved
Ed.
Original
Pingist
Date
Date
Modification
Appr
07.02.2018
Name
Size DIN A2
Sheet
16
/
5
Optional
>> Options
3
3
==CH+03148020/56.07
Solenoid interlock AZM
161CC-12/03RKA-024
-K1
-KBD
-KBD
-KBD
-KBD
(only for service)
(only f
or service)
(only for service)
(only for service)
- not used -
-DIC
-DIC
-DIC
-DIC
Distributor TX_V2
Connector panel
-MON1
-MON1
-MON1
-MON1
Control Computor
Monitor DV1225-007 12.1 inch multi-touch
Moni
tor DV1225-007 12.1 inch multi-touch
Monitor DV1225-007 12.1 inch multi-touch
Monitor DV1225-007 12.1 inch multi-touch
03156514
==CH+CTRL/60.01
-PC
-PC
-PC
-PC
Control computer BoxPC-427D i3 2xPCIe
Contr
ol computer BoxPC-427D i3 2xPCIe
Control computer BoxPC-427D i3 2xPCIe
Control computer BoxPC-427D i3 2xPCIe
03114177
==CH+CTRL/60.02
-X2
-
X2
-X2
-X2
DVI-I
-X5
-
X5
-X5
-X5
USB(IN)
-X70
-
X70
-X70
-X70
DVI-I
-X61
-
X61
-X61
-X61
USB1
USB cable A-plug - B-plug
03148092
03148092
03148092
03148092
-W61
-
W61
-W61
-W61
-X61.PC
-X61.PC
-X61.PC
-X61.PC
-X5.MON1
-X5.MON1
-X5.MON1
-X5.MON1
-X80
-
X80
-X80
-X80
Power
max 4A
100W
-CIN
-CIN
-CIN
-CIN
Control Computor
CAN Interface CIN
CAN I
nterface CIN
CAN Interface CIN
CAN Interface CIN
03108598
==CH+CTRL/60.00
-MON2
-MON2
-MON2
-MON2
Control Computor
Monitor DV1225-007 12.1 inch multi-touch
Moni
tor DV1225-007 12.1 inch multi-touch
Monitor DV1225-007 12.1 inch multi-touch
Monitor DV1225-007 12.1 inch multi-touch
Master
Master
Master
Master
03156514
==CH+CTRL/60.05
-X2
-
X2
-X2
-X2
DVI-I
-X5
-
X5
-X5
-X5
USB(IN)
DVI-D cable 24+1
03148093
03148093
03148093
03148093
-W64
-
W64
-W64
-W64
USB cable A-plug - B-plug
03148094
03148094
03148094
03148094
-W63
-
W63
-W63
-W63
-X63.PC
-X63.PC
-X63.PC
-X63.PC
-X5.MON2
-X5.MON2
-X5.MON2
-X5.MON2
-X71
-
X71
-X71
-X71
DisplayPort
-X63
-
X63
-X63
-X63
USB3
-POWER
-POWER
-POWER
-POWER
-LAN
-LAN
-LAN
-LAN
-X2P1
-
X2P1
-X2P1
-X2P1
LAN2
Patchkabel Cat.5e FTP
03010478
03010478
03010478
03010478
-W1
-
W1
-W1
-W1
-X1
-
X1
-X1
-X1
RJ45
LAN2
L
AN2
LAN2
LAN2
to line computer
to l
ine computer
to line computer
to line computer
-X1
-
X1
-X1
-X1
Power
-X2.MON2
-
X2.MON2
-X2.MON2
-X2.MON2
-X70.PC
-X70.PC
-X70.PC
-X70.PC
-X2
-
X2
-X2
-X2
LAN2
extern_Connection
-X1.MON1
-
X1.MON1
-X1.MON1
-X1.MON1
Adapter cable DP - DVI
03148091
03148091
03148091
03148091
-W62
-
W62
-W62
-W62
-X71.PC
-X71.PC
-X71.PC
-X71.PC
-X2.MON1
-
X2.MON1
-X2.MON1
-X2.MON1
CAT.6A S-FTP RD
03148158
03148158
03148158
03148158
-W66
-
W66
-W66
-W66
-X1
-
X1
-X1
-X1
RJ45
-X2P1.PC
-
X2P1.PC
-X2P1.PC
-X2P1.PC
-U9
-U9
-U9
-U9
RJ45 Adapter Snap-in
jack-jack shielded
03098672
==CH+CTRL/60.04
-X2
-X1
ÖLFLEX® 150
03147982
03147982
03147982
03147982
-W25.1
-
W25.1
-W25.1
-W25.1
CAT.6A S-FTP RD
03148060
03148060
03148060
03148060
-W60
-
W60
-W60
-W60
-LAN.CIN
-LAN.CIN
-LAN.CIN
-LAN.CIN
RJ45
-X9
-X9
-X9
-X9
-X9.FDC
-X9.FDC
-X9.FDC
-X9.FDC
-X1P1
-
X1P1
-X1P1
-X1P1
LAN1
-X1
-
X1
-X1
-X1
Power
-X1.MON2
-
X1.MON2
-X1.MON2
-X1.MON2
USB(OUT)
USB-STICK
3.0(2.0)
Service
(Data-handling)
USB(OUT)
Service
(keyboard)
-CAN2
-CAN1
-CAN4
-CAN3
-FDC
-FDC
-FDC
-FDC
Fuse & Distribution
Power connector panel
==CH+03147980/52.00
-PC.GigE
-PC.GigE
-PC.GigE
-PC.GigE
GigE Ethernet Adapter dual-Port
PCI-E I350T2BLK
03115569
-PC.LAN
-PC.L
AN
-PC.LAN
-PC.LAN
LAN-Card 2x PCI-Express Gigabit
03118416
-X1
-
X1
-X1
-X1
RJ45
GigE 1
-X2
-
X2
-X2
-X2
RJ45
GigE 2
-X3P1
-
X3P1
-X3P1
-X3P1
RJ45
LAN3
-X4P1
-
X4P1
-X4P1
-X4P1
RJ45
LAN4
PCIe-Slot1 x4 PCIe-Slot2 x1PCIe Riser-extension
-X33
-X33
-X33
-X33 -X36
-X36
-X36
-X36
-X1.HS
-
X1.HS
-X1.HS
-X1.HS
Jumper connector
-SP
-X1P1.PC
-
X1P1.PC
-X1P1.PC
-X1P1.PC
UNITRONIC® LiYY A
12x0,34
03148027
03148027
03148027
03148027
-W45
-
W45
-W45
-W45
-X104.SP
-
X104.SP
-X104.SP
-X104.SP
-X30.DIC
-X30.DIC
-X30.DIC
-X30.DIC
==CH+03148020/56.06
Extension Conveyor
Extension Con
veyor
Extension Conveyor
Extension Conveyor
-S3
-
S3
-S3
-S3
-X1.HS
-
X1.HS
-X1.HS
-X1.HS
-W1
12x0,34
ÖLFLEX® 150
03147982
03147982
03147982
03147982
-W25.2
-
W25.2
-W25.2
-W25.2
-X3P1
-
X3P1
-X3P1
-X3P1
-LAN3
-L
AN3
-LAN3
-LAN3
RJ45
-X30
-X30
-X30
-X30
-X1.HS3
-
X1.HS3
-X1.HS3
-X1.HS3
UNITRONIC® LiYY A
12x0,34
03148033
03148033
03148033
03148033
-W53.1
-
W53.1
-W53.1
-W53.1
-X36.DIC
-X36.DIC
-X36.DIC
-X36.DIC
UNITRONIC® LiYY A
12x0,34
03147991
03147991
03147991
03147991
-W54
-
W54
-W54
-W54
-X34.FCU
-
X34.FCU
-X34.FCU
-X34.FCU
-X50.DIC
-X50.DIC
-X50.DIC
-X50.DIC
-X50
-X50
-X50
-X50
-FCU.CA
-FCU
.CA
-FCU.CA
-FCU.CA
PCBA_FCU Connection Assembly
PCBA_FCU Connection Assembly
PCBA_FCU Connection Assembly
PCBA_FCU Connection Assembly
(FCU Supply Unit)
03154202
==03146501+FCU_CA/66.00
UNITRONIC® LiYY A
16x0,34
03148025
03148025
03148025
03148025
-W50
-
W50
-W50
-W50
-X28.DIC
-X28.DIC
-X28.DIC
-X28.DIC
-X28
-X28
-X28
-X28
-X301.FCUS
-X301.FCUS
-X301.FCUS
-X301.FCUS
FCU-Supply Unit
Safety_Distribution COTi 1&2
03136129
==ME+03153007/41.00
UNITRONIC® LiYCY (TP) A
2x2x0,23
03148032
03148032
03148032
03148032
-W19
-
W19
-W19
-W19
-X105.FC
-
X105.FC
-X105.FC
-X105.FC
-X19.DIC
-X19.DIC
-X19.DIC
-X19.DIC
-X19
-X19
-X19
-X19
-DI
-DI
-DI
-DI
Distributor-Assembly
Distributor
-Assembly
Distributor-Assembly
Distributor-Assembly
I/O - Control Unit
I/O - Contr
ol Unit
I/O - Control Unit
I/O - Control Unit
03147585
==ME+03147585/47.00
UNITRONIC® LiYCY (TP) A
03150072
03150072
03150072
03150072
-W19
-
W19
-W19
-W19
-X30
-
X30
-X30
-X30
Control Vaccum_Pump
Control Interior light off/on
Reserve digital input/output
-X30.DI
-
X30.DI
-X30.DI
-X30.DI
-X33
-
X33
-X33
-X33
Reserve-I/O
& Optional
Laterial channel blower
-X36
-
X36
-X36
-X36
Security Loop extern
& Flap Ex.Conveyor
Single-wire
03148739
03148739
03148739
03148739
-W27
-
W27
-W27
-W27
Ready Made
03148738
03148738
03148738
03148738
-W17
-
W17
-W17
-W17
-X0
-
X0
-X0
-X0
Diagnostic
Master
-X0.CAP1
-X0.CAP1
-X0.CAP1
-X0.CAP1
-X33.DI
-
X33.DI
-X33.DI
-X33.DI
-X36.DI
-
X36.DI
-X36.DI
-X36.DI
Single-wire Single-wire Single-wire
-FD.A1
-FD.A1
-FD.A1
-FD.A1
Fuse- and Distribustion PCB
Power Unit TX V2
==ME+03146155/45.00
-CAP1
-CAP1
-CAP1
-CAP1
DC 300/150
Capacitor Bank
==ME+03146155/43.01
Single-wire
Patchkabel Cat.5e FTP
03093186
03093186
03093186
03093186
-W99
-
W99
-W99
-W99
-CSB
-CSB
-CSB
-CSB
CAT.6A S-FTP RD
03148737
03148737
03148737
03148737
-W17
-
W17
-W17
-W17
Single-wire
Single-wire Single-wire
-X28.DI
-
X28.DI
-X28.DI
-X28.DI
-X28
-
X28
-X28
-X28
COT-insert 1 / Fixed table 1
Signaling & Safety
-X50
-
X50
-X50
-X50
Signaling FCU
Connection Assembly
-X50.DI
-
X50.DI
-X50.DI
-X50.DI
-X14.DI
-
X14.DI
-X14.DI
-X14.DI
-X14
-
X14
-X14
-X14
RS485
for PSU
-X2
-
X2
-X2
-X2
Diagnostic
serial interface
-X10
-
X10
-X10
-X10
Distributor Power
DC 24 V
-X9
-
X9
-X9
-X9
DC 24V CIN &
Monitor
-X9.FD
-X9.FD
-X9.FD
-X9.FD -X10.FD
-X10.FD
-X10.FD
-X10.FD -X2.FD
-X2.FD
-X2.FD
-X2.FD
-X11.DI
-
X11.DI
-X11.DI
-X11.DI
-X21.DI
-
X21.DI
-X21.DI
-X21.DI
-X11
-
X11
-X11
-X11
Diff. Communication to
FUSE-Detection
-X21
-
X21
-X21
-X21
Power 24V DC
-X19.DI
-
X19.DI
-X19.DI
-X19.DI
-X19
-
X19
-X19
-X19
RS485 for
Frequeny_conv.
Vacuum pump
-X22
-
X22
-X22
-X22
Safety-Loop &
Signals
see Block_diagram
CAN_Bus_wiring
==CH+CTRL/60.01
Machine-Canbus 1-4
Sub-D 9pol.male
+-CC_LAN3
+CR_Lector620/38.05
** Optional **
Code-reader Lector260 or
3D_coplanarity_sensor
==+GA1-VBI.1
Vision Base Interface-1
+GA/28.08
==+GA2-VBI.2
Vision Base Interface-2
+GA/29.08
==CH+COTi-FCU_IO_Safety
+COTi/20.05
-COTi_Safety_Switch
+03153007/13.05
-RS485.FC
-RS485.FC
-RS485.FC
-RS485.FC
Communication RS485
Frequenzy_converter
+03155560/12.09
-IO.SP
-
IO.SP
-IO.SP
-IO.SP
Control_Vacuum_pump
Interior_light
+03155560/12.09
DI.Safety
Safety Loop & Signals
from -X29 / -X30
+03146155/14.07
DI.24V
Distributor DC 24 V
+03146155/14.01
==+-X11.DI
Fuse Diagnostic
serial interface Distributor
+03146155/14.05
==DI+-RS485.PSU
USE 100 or 1000 Base-T
+03146155/14.09
-PC1-27V(F33)
+03155560/12.01
from FCUS-PS6
-MON1
Power 24V(F5)
Monitor 1
+03146155/14.01
-MON2
Power 24V(F5)
Monitor 2
+03146155/14.01