00198460-01_DC_SIPLACE_TX-EditionV2_DE EN - 第54页
electric_schematic SIPLACE TX_V2 electric_schematic SIPLACE TX_V2 electric_schematic SIPLACE TX_V2 electric_schematic SIPLACE TX_V2 90012669-010501LE3 Replaced by LED-Display_ LED-Display_ LED-Display_ LED-Display_ Digit…

electric_schematic SIPLACE TX_V2
electric_schematic SIPLACE TX_V2
electric_schematic SIPLACE TX_V2
electric_schematic SIPLACE TX_V2
90012669-010501LE3
Replaced by
Distributor Control Connection & Relay
Distributor Control Connection & Relay
Distributor Control Connection & Relay
Distributor Control Connection & Relay
Replaced by
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und
Mitteilung des Inhalts nicht gestattet, soweit nicht ausdrücklich zugestanden.
Proprietary Data, company confidential.
All rights reserved
Copying of this document, giving it to others and the use or
communication of the contents thereof, are forbidden without express authority.
Doc. No.
00 01 02 03 04 05 06 07 08 09
Privileged business information.
Do not release
Offenders are liable to payment of damages. All rights are reserved in the
event of the grant or the registration of a utility model or design.
Zuwiederhandlungen verpflichten zu Schadenersatz. Alle Rechte vorbehalten,
insbesondere für den Fall der Patenterteilung oder GM-Eintragung vorbehalten.
Page:
Function: Main Electrics
==ME=TX+03147585/48
drawing number:
03156683-010101LE3
Distributor_Berlin
Distributor_B
erlin
Distributor_Berlin
Distributor_Berlin
GmbH & Co KG
ASM
Assembly Systems
Copyright reserved
Ed.
Original
Pingist
Date
Date
Modification
Appr
07.02.2018
Name
Size DIN A2
Sheet
48
/
3
1 2 3 4 6 7 85
LITTLEFUSE
33V 1,1A
SMT 1812
1 2 3 4 6 7 8 129 10 115
LITTLEFUSE
13,2V 0,75A
SMT 1812
LITTLEFUSE
13,2V 0,75A
SMT 1812
SHIELD SHIELD
Functional
Grounding
Functional
Grounding
ON
ON
ON
ONON
ON
ON
ON
Note:
The relay contact drawing shows the relay
in the non-active mode (normal position).
- not used -
- not used -
Note:
The relay contact drawing shows the relay
in the non-active mode (normal position).
Test button
Test button
- only for Service -
-X14
-X14
-X14
-X14
RS485
RS485
RS485
RS485
for PSU
f
or PSU
for PSU
for PSU
1 2 3 4 5 6 87
-X14.DI
-
X14.DI
-X14.DI
-X14.DI
RS485/PSU
RJ45
1 2 3 4 5 6 7 8
RS485_OUT_NINV
RS485_OUT_INV
RS485_IN_INV
RS485_IN_NINV
-LGND
-LGND
-F3
+24V0
-X11
-
X11
-X11
-X11
Diff. Communication to
Di
ff. Communication to
Diff. Communication to
Diff. Communication to
FUSE-Detection
FUSE-Detection
FUSE-Detection
FUSE-Detection
FUSE_IN_MISO_NINV
FUSE_IN_MISO_INV
FUSE_OUT_CLK_NINV
FUSE_OUT_CLK_INV
FUSE_OUT_LATCH_NINV
FUSE_OUT_LATCH_INV
MTSR
EXT1
EXT2
DETECT_DISTRBRD
-LGND
-F2
1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
-X11.DI
-
X11.DI
-X11.DI
-X11.DI
Fuse-Diagnostic
serial interface
+5V0
-X10
-
X10
-X10
-X10
Analog + Program
Analog + Pr
ogram
Analog + Program
Analog + Program
1 2 3 4 5 6 7 8 9 10 11 12 13 14
AI_0
AI_1
AI_2
AI_3
AI_4
AI_5
AI_6
AI_7
-LGND
-AGND
TRST_N
+5V0
TXD0_0
-F4
-R297
120 Ohm
-R298
4k7
RXD0_0
-R378
10k
-LGND
9 13 10 14
-R34
0 Ohm
-LGND -AGND
-DI
-DI
-DI
-DI
Distributor-Assembly TX_V2
Distributor
-Assembly TX_V2
Distributor-Assembly TX_V2
Distributor-Assembly TX_V2
I/O - Control Unit
I/O - Contr
ol Unit
I/O - Control Unit
I/O - Control Unit
03147585
03147585
03147585
03147585
-X98
-
X98
-X98
-X98
Debug
Debug
Debug
Debug
1 2 3 4 5 6 87 109
-LGND
TDI
-R1
120 Ohm
-R158
120 Ohm
RSTIN_N
TRST_N
BRKOUT_N
TMS
+3V3
TDO
BRKIN_N
TCK
-X37
-X37
-X37
-X37
Reserve-I/O
R
eserve-I/O
Reserve-I/O
Reserve-I/O
K3_Connection
K3_Connection
K3_Connection
K3_Connection
Mini-Mate-N-Look 16pol(Dual Row)
1-794075-0
8
K3_11
1 2 6 129
K3_12
7
K3_14
1110
K3_A1+
3 4 5 13 1514 16
-DI
-DI
-DI
-DI
Distributor-Assembly TX_V2
Distributor
-Assembly TX_V2
Distributor-Assembly TX_V2
Distributor-Assembly TX_V2
I/O - Control Unit
I/O - Contr
ol Unit
I/O - Control Unit
I/O - Control Unit
03147585
03147585
03147585
03147585
1
2
3
1
-J1.K3
-
J1.K3
-J1.K3
-J1.K3
Jumper J1
Jumper J1
Jumper J1
Jumper J1
for -X40
f
or -X40
for -X40
for -X40
2
-X40
-X40
-X40
-X40
1
2
3
K3_A1+
1
-J2.K3
-J2.K3
-J2.K3
-J2.K3
Jumper J2
Jumper J2
Jumper J2
Jumper J2
for -X41
f
or -X41
for -X41
for -X41
2
-X41
-X41
-X41
-X41
A1+
A2-
14
11
K3_12
12
-K4
-K4
-K4
-K4
Slimline PCB Relay SNR
Rated current 6A, Coil: 24VDC
V23092A1024A201 (2-1393236-1)
03131716
D22
-LGND
5 (A1+)
1 (A2-)
4 (11)
2 (12)
3 (14)
-K3
-K3
-K3
-K3
Fan control (ON/OFF)
F
an control (ON/OFF)
Fan control (ON/OFF)
Fan control (ON/OFF)
Finder - Miniature industrial relays, 16 A
46 Series (46.61.9.024.0040)
03123859
-D99
-D57
-LGND
-LGND
5 (A1+)
1 (A2-)
4 (11)
2 (12)
3 (14)
-K2
-K2
-K2
-K2
Finder - Miniature industrial relays, 16 A
46 Series (46.61.9.024.0040)
03123859
-D136
-D137
-LGND
-LGND
3
8
5
1
10
-K1
-K1
-K1
-K1
Fan control (ON/OFF)
F
an control (ON/OFF)
Fan control (ON/OFF)
Fan control (ON/OFF)
Signal Relays
Rated current: 1A
Coil voltage: 24VDC
V23026-D1024-B201-125V (1393776-7)
03151288
-D100
-LGND
-RS485_PSU
RS485 Power supply units
+03146155/43.06
-W17.1
-RS485_DIAG_F&D
Fuse and distribution
Diagnostic serial interface
+03146155/45.07
-W17
-FG
-FG
-FG
-FG
-FG
-FG
-FG
-FG
-DO0_Res
/49.06
-DO8_Res
/49.07
-24V(F12)_S
/47.03
-DI23_Res
/49.03
-DI22_Res
/49.03
-DI21_Res
/49.03
-DO19_Res
/49.09
-24V(F4)
/47.06
-24V(F4)
/47.06
-LGND
/47.06
-LGND
/47.06
+-24V(F4)
/47.06
-DO8_Res
/49.07
-DO20_Fan_Contr
49.09
-24V(F4)
47.06
-24V(F4)
47.06
-24V(F12)_S
47.03
-24V(F4)_K2
OUT20(K2) / Safety(K1)
to Connector -X34
==CH+03148020/59.01
-24V(F4)_K3
OUT20(K3)
to Connector -X35
==CH+03148020/59.05

electric_schematic SIPLACE TX_V2
electric_schematic SIPLACE TX_V2
electric_schematic SIPLACE TX_V2
electric_schematic SIPLACE TX_V2
90012669-010501LE3
Replaced by
LED-Display_
LED-Display_
LED-Display_
LED-Display_
Digital I/O
Digi
tal I/O
Digital I/O
Digital I/O
Replaced by
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und
Mitteilung des Inhalts nicht gestattet, soweit nicht ausdrücklich zugestanden.
Proprietary Data, company confidential.
All rights reserved
Copying of this document, giving it to others and the use or
communication of the contents thereof, are forbidden without express authority.
Doc. No.
00 01 02 03 04 05 06 07 08 09
Privileged business information.
Do not release
Offenders are liable to payment of damages. All rights are reserved in the
event of the grant or the registration of a utility model or design.
Zuwiederhandlungen verpflichten zu Schadenersatz. Alle Rechte vorbehalten,
insbesondere für den Fall der Patenterteilung oder GM-Eintragung vorbehalten.
Page:
Function: Main Electrics
==ME=TX+03147585/49
drawing number:
03156683-010101LE3
Distributor_Berlin
Distributor_B
erlin
Distributor_Berlin
Distributor_Berlin
GmbH & Co KG
ASM
Assembly Systems
Copyright reserved
Ed.
Original
Pingist
Date
Date
Modification
Appr
17.04.2018
Name
Size DIN A2
Sheet
49
/
3
Optical LED display
- Digital-Input
- Digital-Output signals
Digital inputs DI_0 … DI_7
Digital inputs DI_8 … DI_15 Digital inputs DI_16 … DI_23 Digital inputs DI_24 … DI_31 Digital inputs DI_32 … DI_39 Digital outputs DO_0 … DO_7 Digital outputs DO_8 … DO_15 Digital outputs DO_16 … DO_23
Digital input stage with decoupling diode
Digital input stage
Decoupling diode Decoupling diode
Digital input stage / FAN control and monitoring
Sensor poutput _ FAN
DI_3
DI_6
DI_5
DI_4
D_2
DI_1
DI_0
DI_7
DI_8
DI_9
DI_10
DI_11
DI_12
DI_13
DI_14
DI_15
DI_19
DI_23
DI_22
DI_21
DI_20
DI_18
DI_17
DI_16
DI_27
DI_31
DI_30
DI_29
DI_28
DI_26
DI_25
DI_24
/DI_35
/DI_39
/DI_38
/DI_37
/DI_36
/DI_34
/DI_33
/DI_32
DO_6
DO_5
DO_4
DO_3
DO_2
DO_1
DO_0
DO_7
DO_14
DO_13
DO_12
DO_11
DO_10
DO_9
DO_8
DO_15
DO_22
DO_21
DO_20
DO_19
DO_18
DO_17
DO_16
DO_23
D56
DI18
D55
DI17
D59
DI22
D58
DI21
D61
DI26
D60
DI25
D65
DI30
D64
DI29
-DI
-DI
-DI
-DI
Distributor-Assembly TX_V2
Distributor-Assembly TX_V2
Distributor-Assembly TX_V2
Distributor-Assembly TX_V2
I/O - Control Unit
I/O - Contr
ol Unit
I/O - Control Unit
I/O - Control Unit
03147585
03147585
03147585
03147585
-DI2_EMG_Stop_2
==CH+03148020/55.05
-DI4_PresSens_PV1
==CH+03148020/58.01
-DI5_PresSens_MainValve
(not used)
==CH+03148020/58.01
-DI0_Safety_Loop_OK
/47.03
-DI3_Res
==CH+03148020/58.01
-DI1_Res
==CH+03148020/58.08
-DI8_Start_Button_1
==CH+03148020/55.01
==CH+03148020/55.08
-DI9_Stop_Button_1
==CH+03148020/55.02
==CH+03148020/55.08
-DI10_24V(F12)_S
/47.03
-DI11_Start_Button_2
==CH+03148020/55.05
-DI12_Stop_Button_2
==CH+03148020/55.05
-DI13_PWR_ENA
/47.03
-DI14_EMG_Stop_1
==CH+03148020/55.02
-DI15_EMG_Stop_Ext
==CH+03148020/55.09
==CH+03148020/57.01
==CH+03148020/57.04
-DI16_Button_COTi_2
==CH+03148020/55.05
-DI17_Hood_2
==CH+03148020/56.05
-DI18_Comp_Table_2
==CH+03148020/57.03
==CH+03148020/57.06
-DI22_Res
/48.06
-DI21_Res
/48.06
-DI23_Res
/48.06
-DI19_Hood2_Lock_on
==CH+03148020/56.05
-DI20_Res
==CH+03148020/58.08
-DI24_Button_COTi_1
==CH+03148020/55.02
-DI25_Hood_1
==CH+03148020/56.02
-DI26_Comp_Table_1
==CH+03148020/57.01
==CH+03148020/57.06
-DI30_Res
(Flap_Lock_on_ExCO)
==CH+03148020/56.08
-DI31_Res
(Option Identify_extension_Conveyor)
==CH+03148020/56.08
-DI28_Res
==CH+03148020/58.08
==CH+03148020/59.07
-DI27_Hood1_Lock_on
==CH+03148020/56.02
-DI32_Fan_1
==CH+03148020/59.00
-DI33_Fan_2
==CH+03148020/59.00
-DI34_Fan_3
==CH+03148020/59.01
-DI35_Fan_4
==CH+03148020/59.01
-DI36_Fan_5
==CH+03148020/59.04
-DI37_Fan_6
==CH+03148020/59.04
-DI38_Fan_7
==CH+03148020/59.04
-DI39_Fan_8
==CH+03148020/59.05
-DO1_Control_ON
==CH+03148020/55.01
==CH+03148020/55.04
==CH+03148020/55.07
-DO3_Pressure_PV1
==CH+03148020/58.02
-DO7_Interior_light
==CH+03148020/59.07
-DO4_Hood_Lock2
==CH+03148020/56.04
-DO5_Hood_Lock1
==CH+03148020/56.01
-DO2_Res
==CH+03148020/58.02
-DO0_Res
/48.07
-DO10_Indicator_1_RD
==CH+03148020/58.05
-DO11_Indicator_2_RD
==CH+03148020/58.05
-DO12_Indicator_1_GN
==CH+03148020/58.04
-DO13_Indicator_1_YE
(Optonal WH)
==CH+03148020/58.04
-DO14_Indicator_2_YE
(Optonal WH)
==CH+03148020/58.05
-DO15_Indicator_2_GN
==CH+03148020/58.05
-DO9_Buzzer
==CH+03148020/58.05
-DO8_Res
/48.06
/48.07
-DO18_Service
==CH+03148020/55.08
-DO17_Service
==CH+03148020/55.08
-DO16_Service
==CH+03148020/55.08
-DO23_Res
==CH+03148020/58.08
-DO22_Res
==CH+03148020/58.08
-DO21_Res
==CH+03148020/58.08
-DO20_Fan_Contr
/48.03
-DI29_Flap_ExCO
==CH+03148020/56.08
-DO6_Res
(Reserve Vac_Pump_ON)
==CH+03148020/59.07
-DO19_Res
/48.07
==CH+03148020/56.07
-DI6_Identify_VP
(Vacuum_Pump)
==CH+03148020/59.07
-DI7_Identify_FC
(Frequency_Conv.)
==CH+03148020/59.07

electric_schematic SIPLACE TX_V2
electric_schematic SIPLACE TX_V2
electric_schematic SIPLACE TX_V2
electric_schematic SIPLACE TX_V2
90012669-010501LE3
Replaced by
Vacuum Pump Control QM1 Panel
Vacuum Pump Control QM1 Panel
Vacuum Pump Control QM1 Panel
Vacuum Pump Control QM1 Panel
(Option)
(Option)
(Option)
(Option)
Replaced by
Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und
Mitteilung des Inhalts nicht gestattet, soweit nicht ausdrücklich zugestanden.
Proprietary Data, company confidential.
All rights reserved
Copying of this document, giving it to others and the use or
communication of the contents thereof, are forbidden without express authority.
Doc. No.
0 1 2 3 4 5 6 7 8 9
Privileged business information.
Do not release
Offenders are liable to payment of damages. All rights are reserved in the
event of the grant or the registration of a utility model or design.
Zuwiederhandlungen verpflichten zu Schadenersatz. Alle Rechte vorbehalten,
insbesondere für den Fall der Patenterteilung oder GM-Eintragung vorbehalten.
Page:
Function: Main Electrics
==ME=TX+03159886/50
drawing number:
03151645-010101LE3
Vacuum Pump Module
V
acuum Pump Module
Vacuum Pump Module
Vacuum Pump Module
GmbH & Co KG
ASM
Assembly Systems
Copyright reserved
Ed.
Original
Pingist
Date
Date
Modification
Appr
19.02.2018
Name
Size DIN A2
Sheet
50
/
1
Line Line Line
Configuration
always star connection
Line-voltage = 380-415VAC
Line-voltage = 380-415VAC
Line-voltage = 380-415VAC
Line-voltage = 380-415VAC
or
or
or
or
T1-voltage = 415VAC
T1-voltage = 415VAC
T1-voltage = 415VAC
T1-voltage = 415VAC
PE1
PE-Frame
Mechanics_base_plate: 03151650
Mechanics_base_plate: 03151650
Mechanics_base_plate: 03151650
Mechanics_base_plate: 03151650
Phase barrier 3RV2928-1K
03112171
Phase barrier 3RV2928-1K
03112171
2
T1.V
1
T1.U
3
T1.W
PE
PE
-X1.VP
-X1.VP
-X1.VP
-X1.VP
Power
P
ower
Power
Power
Vacuum pump
Vacuum pump
Vacuum pump
Vacuum pump
Female insert CQF 05-pin + PE 16A
Bulkhead housing CK 03 I
not used =
bimetallic-switch
-PE_Frame.VP
1
V1W1 U1
W2U2V2
-X1.FC
-
X1.FC
-X1.FC
-X1.FC
Power connection
Power connection
Power connection
Power connection
Male insert CQM 05-pin + PE 16A
Bulkhead housing CK 03 I
Instruction before implementation:
controlling Bridge: Pin-4 to Pin-5
Bulkhead housing
without interlock-tool
1 2 43 5 PE
4
B1.1
5
B1.2
-VACP1
Becker Vacuum-Pump
B
ecker Vacuum-Pump
Becker Vacuum-Pump
Becker Vacuum-Pump
Type: VX4.25 (0,75KW, 25m³/h)
03069679
B1.1
B1.1
B1.1
B1.1 B1.2
B1.2
B1.2
B1.2
U2 W2V2
PE
PE
PE
PEV1
V1
V1
V1 U1
U1
U1
U1W1
W1
W1
W1
-M1
-M1
-M1
-M1
PE
3~
M
-X1.VP
-
X1.VP
-X1.VP
-X1.VP
Male insert CQM 05-pin + PE 16A
1 2 43 5 PE
1400 mm
7G0,75
ÖLFLEX 150CY UL
03079997
03079997
03079997
03079997
-03
-03
-03
-03
-W1
-
W1
-W1
-W1
4
5
GNYE
3
2
1
4
PE1
==ME=TX+03159886#03159889
==ME=TX+03159886#03159889
==ME=TX+03159886#03159889
==ME=TX+03159886#03159889
Vacuum Panel QM1
V
acuum Panel QM1
Vacuum Panel QM1
Vacuum Panel QM1
Option
150 mm
Single core 4x
BK 16 AWG
BK 16 AWG
BK 16 AWG
GNYE 16 AWG
-B1
bimetallic-switch
150°C
21
-X1.VP
-
X1.VP
-X1.VP
-X1.VP
Power
Vacuum pump
Female insert CQF 05-pin + PE 16A
/50.3
-X1.FC
-
X1.FC
-X1.FC
-X1.FC
Power connection
Male insert CQM 05-pin + PE 16A
without interlock-tool
/50.3
behind
==FLUID+-VACP
Pneumatics
250 mm
Single core 3x
BK 16 AWG
BK 16 AWG
BK 16 AWG
BK 16 AWG
60 mm
-QM1
-QM1
-QM1
-QM1
Vacuum_Pump
V
acuum_Pump
Vacuum_Pump
Vacuum_Pump
Power switch
including protection
SIE.3RV2011-1DA10
2,2 - 3,2A
ajdusting=3A
ajdusting=3A
ajdusting=3A
ajdusting=3A
03158435
2x Phase barrier 3RV2928-1K
03112171
1
2
3
4
5
6
I>
I>
I>
-QM1
-QM1
-QM1
-QM1
Power switch
including protection
2,2 - 3,2A
ajdusting=3A
03158435
/50.3
GNYE 16 AWG 150 mm
GNYE 16 AWG 150 mm
400VAC_QM1
Optional via Transformer
+03155560/39.7
Female insert
Male insert