4 – 141 Data ty pe Item Error conditions Placement of vision components (0.8 <= the smallest pitch < 1.0 mm) (Ball components) The optional 37.5 mm, 27 mm or 18 mm VCS is not set i n Placement da ta of vision com p…

4 – 140
(3-4) Coherence check items: error conditions
Data type Item Error conditions
Placement of vision
components (over 0.4 mm)
(Lead components)
The standard VCS or optional VCS (37.5 mm, 27 mm or 18
mm) is not set in Placement data of vision components
whose size is 0.4 mm or larger.
Placement of vision
components (0.3 <= Pitch < 0.4
mm) (Lead components)
The optional VCS (37.5 mm, 27 mm or 18 mm) is not set in
Placement data of vision components whose pitch is 0.3 mm
or wider, but narrower than 0.4 mm.
Placement of vision
components (0.2 <= Pitch < 0.3
mm) (Lead components)
The optional VCS (27 mm or 18 mm) is not set in Placement
data of vision components whose pitch is 0.2 mm or wider,
but narrower than 0.3 mm.
Placement of vision
components (0.135 <= Pitch <
0.2 mm) (Lead components)
The optional 18 mm VCS is not set in Placement data of
vision components whose pitch is 0.135 mm or wider, but
narrower than 0.2 mm.
Division recognition of an
extended-lead connector
If split (division) recognition is selected at the control data
menu item of an extended-lead connector (only batch
recognition is available).
Placement of general vision
components (15 < the smallest
pitch <= 22 mm) (Lead
components)
The standard VCS is not set in Placement data of general
vision components whose minimum pitch is wider than 15
mm, but 22 mm or narrower.
Placement of general vision
components (11 < the smallest
pitch <=15 mm) (Lead
components)
The standard VCS or optional 37.5 mm VCS is not set in
Placement data of general vision components whose
minimum pitch is wider than 11 mm, but 15 mm or narrower.
Placement of general vision
components (6.5 < the smallest
pitch <= 11 mm) (Lead
components)
The standard VCS or optional 37.5 mm or 27 mm VCS is not
set in Placement data of general vision components whose
minimum pitch is wider than 6.5 mm, but 11 mm or narrower.
Placement of general vision
components (0.5 <= the
smallest pitch <=6.5 mm)
(Lead components)
The standard VCS or optional 37.5 mm, 27 mm or 18 mm
VCS is not set in Placement data of general vision
components whose minimum pitch is 0.5 mm or wider, but
6.5 mm or narrower.
Placement of general vision
components (0.4 <= the
smallest pitch <0.5 mm) (Lead
components)
The optional 37.5 mm, 27 mm or 18 mm VCS is not set in
Placement data of general vision components whose
minimum pitch is 0.4 mm or wider, but narrower than 0.5 mm.
Placement of general vision
components (0.3 <= the
smallest pitch < 0.3 mm) (Lead
components)
The optional 27 mm or 18 mm VCS is not set in Placement
data of general vision components whose minimum pitch is
0.3 mm or wider, but narrower than 0.4 mm.
Placement of general vision
components (0.2 <= the
smallest pitch < 0.3 mm) (Lead
components)
The optional 18 mm VCS is not set in Placement data of
general vision components whose minimum pitch is 0.2 mm
or wider, but narrower than 0.3 mm.
Placement of vision
components (15 < the smallest
pitch <= 22 mm) (Ball
components)
The standard VCS is not set in Placement data of vision
components whose minimum pitch is wider than 15 mm, but
22 mm or narrower.
Placement of vision
components (11 < the smallest
pitch <15 mm) (Ball
components)
The standard VCS or optional 37.5 mm VCS is not set in
Placement data of vision components whose minimum pitch
is wider than 11 mm, but 15 mm or narrower.
Placement of vision
components (6.5 < the smallest
pitch <= 11 mm) (Ball
components)
The standard VCS or optional 37.5 mm or 27 mm VCS is not
set in Placement data of vision components whose minimum
pitch is wider than 6.5 mm, but 11 mm or narrower.
Vision data
Placement of vision
components (1.0 <= the
smallest pitch < 6.5 mm) (Ball
components)
The standard VCS optional 37.5 mm, 27 mm or 18 mm VCS
is not set in Placement data of vision components whose
minimum pitch is wider than 1.0 mm, but 6.5 mm or narrower.

4 – 141
Data type Item Error conditions
Placement of vision
components (0.8 <= the
smallest pitch < 1.0 mm) (Ball
components)
The optional 37.5 mm, 27 mm or 18 mm VCS is not set in
Placement data of vision components whose minimum pitch
is 0.8 mm or wider, but narrower than 1.0 mm.
Placement of vision
components (0.5 <= the
smallest pitch < 0.8 mm) (Ball
components)
The optional 27 mm or 18 mm VCS is not set in Placement
data of vision components whose minimum pitch is 0.5 mm or
wider, but narrower than 0.8 mm.
Placement of vision
components (0.35 <= the
smallest pitch < 0.5 mm) (Ball
components)
The optional 18 mm VCS is not set in Placement data of
vision components whose minimum pitch is 0.35 mm or
wider, but narrower than 0.5 mm.
The BGA vision recognition function cannot be used with the
station in Pick data of all balls or all lands vision recognition
components.
If the pitch width is equal to the pith length in the pick data on
vision all ball or all land recognition components (for a BGA
component, the width and length are 2.00 mm or longer and
for an FBGA component, they are 1.00 mm or longer), and
one of the standard type BGA, peripheral type BGA and user
ball pattern is selected as a ball pattern, but there is no
KE-2000 series station.
Pick-up of all balls or all lands
vision recognition components
If the pitch width is not equal to the pitch length and there is
no KE-2000 series station.
Number of all balls or all lands
vision recognition ball pattern
components
The number of user-defined ball pattern components in Pick
data is found to exceed 10 with the all balls or all lands vision
recognition function.
Error conditions of the VCS recognition type specified on the
MSL setup menu and the light type specified in Light data
VCS recognition type
Reflective
light
Penetra-
tive light
Side light
No recognition × × ×
BGA vision recognition × × ○
Penetrative recognition × ○ ×
Reflective recognition ○ × ×
BGA, penetrative × ○ ○
BGA, reflective ○ × ○
Penetrative, reflective ○ ○ ×
BGA, Penetrative, reflective ○ ○ ○
Light type
Component for which you can
select “Vision centering
component” as its component
type
The component size is smaller than 0.6 mm.
For components that undergo
coplanarity inspection (2000
series only)
The longer side of the component size exceeds 50 mm and
the height of the component exceeds 8.00 mm.
The “standard measurement mode” is selected and the
longer side of the component size exceeds 100 mm.
Coplanarity measurement
mode
The “high-accuracy measurement mode” is selected and the
longer side of the component exceeds 50 mm.

4 – 142
Data type Item Error conditions
Lead/ball pitch
If any optional VCS is not set on the control data when the
pitch of a lead component (SOP, QFP, BQFP, (PQFP), TSOP,
TSOP2, CONN, CON2, CONZ, CONX, SOT, aluminum
electrolytic capacitor, GaAsFET, HSOP, SOJ, QFJ (PLCC),
J-lead socket, Gull-wing socket or socket with a bumper) is
narrower than 0.38 mm.
If any optional VCS is not set on the control data when the
pitch of a ball component (BGA, FBGA) is narrower than 1.00
mm.
If the standard VCS is not set on the control data when the
pitch of a ball component (BGA, FBGA) is wider than 2.00
mm.
Optimization
option
Non-stop option
− The IC recovery belt is used on the rear side although
“Front to Rear” is selected from the “Primary Secondary”
pull-down menu
- If the area is set to “front” or “rear”.
− A DTS is installed on your system, and “No” is not selected
from the “Feeder” pull-down menu on the “Non-Stop”
option tab.
− A tray holder is used and the menu item “Feeder” on the
“Non-stop” tab is not set to “No”.
- “Arrange priority” is set to a KE-2000 on the “Non-Stop”
tab.
(That is, the line includes a KE-2000 station, and the
“Arrange priority” is set to “Line” on the “Non-Stop” option
tab.
− A belt feeder is used and the menu item “Feeder” on the
“Non-stop” tab is not set to “No”.
− “No” is not selected from the “Feeder” pull-down menu on
the “Non-Stop” option tab even though the machine is not
designed for not-stop operation (this option is not installed
on the station).
− Stick changer components are used and Feeder Non-Stop
is not set to “No”. (2000 series only)