KE2040Instruction Manual Ver2.01,REV04.2003.6.25 - 第610页
7 − 128 7.7.1.3. 2 “Veri ficati on” single check di alog box W hen you click the <VERIFY> but ton on the “Ver ificat ion” component selection dialog box shown in Figure 7.7.1. 3.1, t he following dialog box appears…

7 − 127
⑥ Manual pick-up
If there is no Pick data, you can attach a component on a nozzle manually. In
such a case, you cannot enter any coordinate of a component pick-up position.
You cannot operate any feeder either.
Figure 7.7.1.2.1 “Question” dialog box
7.7.1.3 Single verification check
7.7.1.3.1 “Verification” component selection dialog box
When you select the [Tool] command from the menu bar, the [Check] command on
the “Tool” menu, and the [Verification] command on the Production menu, the
following dialog box appears on the screen.
− The “NO.:Name” combo box lists square chips whose menu item “Verify” is set
to “Yes” on the Component data screen.
− Select a component to be checked.
Figure 7.7.1.3.1 “Verification” single check component selection dialog box

7 − 128
7.7.1.3.2 “Verification” single check dialog box
When you click the <VERIFY> button on the “Verification” component selection
dialog box shown in Figure 7.7.1.3.1, the following dialog box appears on the
screen.
Figure 7.7.1.3.2 “Verification” single check dialog box
− Component of verification
Data on a component selected to be checked appears here.
− Pickup position
Data on the component pick-up position appears here. You can change the
pick-up position to that of the previous alternate component or the next
alternate component also.
① <FEED> button
When you click this button, the system knocks a feeder once to feed a
component (not available with a 32-mm paper tape).
② Check box “Update pick data with new coordinates.”
Check this check box if you want to store the result of teaching operation by
the HOD device onto Pick data.
◇ If you do not check this check box, the specified coordinates are applied
to the current pick-up position only.
− Result of verification
The “Verification item”, “Standard” value, the upper limit of allowable values
(“Max.perm.”) and the lower limit of allowable values (“Min.perm.”) appear
here.
− After checking a component, the system displays the measured value at
the item “Measurement value”.

7 − 129
− Shortcut keys
On the “Verification” single check dialog box, the following shortcut keys are
available.
Table 7.7.1.3 Shortcut keys
Keyboard Operation panel HOD key Action
F10 ENTER Executes a single verification check.
F4 Knocks a feeder.
F5 PREVIOUS Previous alternate component
F6 NEXT Next alternate component
ESC CANCEL Returns to the previous screen.
7.7.1.3.3 “Executing verification…” dialog box
When you click the <VERIFY> button on the “Verification” single check dialog box
shown in Figure 7.7.1.3.2, the following dialog box appears on the screen.
Figure 7.7.1.3.3 “Executing verification…” dialog box
− Component of verification
− Displays the data on a component that the system is checking.
− Verified value
− Displays the “Verification item”, “Standard” value, the upper limit of allowable
values (“Max.perm.”) , the lower limit of allowable values (“Min.perm.”) and the
current operation here.