KE2040Instruction Manual Ver2.01,REV04.2003.6.25 - 第777页

10 − 14 10.4.2.4 Setting the error level W hen you select the [Tool] command on t he menu bar, t he [The Er ror level is set] command on the displayed menu, t hen the [Each nozzle] command, t he screen appears as shown i…

100%1 / 1491
10 13
10.4.2.3 Setting the warning level
When you select the [Tool] command on the menu bar, the [The Warning level is set]
command on the displayed menu, then the [Each nozzle] Command the screen
appears as shown in Figure 10.4.2.3.1.
Figure 10.4.2.3.1 <Warning level is set> dialog box
If the number of times components were picked up actually exceeds the warning
level you set here, the nozzle is displayed in yellow on the "Operation Information
of each nozzle" screen shown in Figure 10.4.2.1.1.
The signal lights lighting condition remains unchanged.
10 14
10.4.2.4 Setting the error level
When you select the [Tool] command on the menu bar, the [The Error level is set]
command on the displayed menu, then the [Each nozzle] command, the screen
appears as shown in Figure 10.4.2.4.1.
This screen allows you to set the error level.
Figure 10.4.2.4.1 "The error level is set" dialog box
If the number of times components were picked up actually exceeds the error
level you set here, the nozzle is displayed in red on the "Operation Information of
each nozzle" screen shown in Figure 10.4.2.1.1.
The signal lights lighting condition remains unchanged.
10 15
10.4.3 Head operating information
10.4.3.1 Operation information of each head
When you select the [Windows] command on the menu bar, then the [Operation
Information of each head] command on the displayed menu, the screen appears as
shown in Figure 10.4.3.1
No. Item Description
1 Nozzle replacement count (Nozzle L1) Displays how many times the nozzle L1 was replaced.
2 Nozzle replacement count (Nozzle L2) Displays how many times the nozzle L2 was replaced.
3 Nozzle replacement count (Nozzle L3) Displays how many times the nozzle L3 was replaced.
4 Nozzle replacement count (Nozzle L4) Displays how many times the nozzle L4 was replaced.
5
Nozzle replacement count (Nozzle
R1)
Displays how many times the nozzle R1 was replaced.
6 Nozzle replacement count
Displays how many times the nozzle was replaced per
a cylinder.
7 Slide plate open/shut count
Displays how many times the slide plate was
opened/closed.
Figure 10.4.3.1 Operation Information of each head