KE2040Instruction Manual Ver2.01,REV04.2003.6.25 - 第892页
14 − 8 14.2.4.2 FM LA Head 1) Loosen the scr ew ② fixing t he Z slide shaft ① t o pull out the nozzle outer shaf t ③ . 2) Check to see if ther e is any contamination of the f ilter ④ . 3) I f any, r emove the f ilter ④ f…

14 − 7
14.2.4 Air filter (MNLA Head/FMLA Head)
14.2.4.1 MNLA Head
1) Loosen the screw ② fixing the Z slide shaft ① to pull out the nozzle outer shaft
③.
2) Check to see if there is any contamination of the filter ④.
3) If any, remove the filter ④ from the nozzle outer shaft, the replace it with a new
one.
4) Push the nozzle outer shaft ③ into the Z slide shaft ①, then fix it with the screw
②.
Filter ④: Part number E3052729000
WARNING
To prevent the body from injury which can be caused by accidental
activation of the machine, turn off the power of the machine before
following the operation above.
④
③
②
①

14 − 8
14.2.4.2 FMLA Head
1) Loosen the screw ② fixing the Z slide shaft ① to pull out the nozzle outer shaft
③.
2) Check to see if there is any contamination of the filter ④.
3) If any, remove the filter ④ from the nozzle outer shaft, the replace it with a new
one.
4) Push the nozzle outer shaft ③ into the Z slide shaft ①, then fix it with the screw
②.
Filter ④: Part number E3052729000
WARNING
To prevent the body from injury which can be caused by accidental
activation of the machine, turn off the power of the machine before
following the operation above.
②
①
④
③

14 − 9
14.2.5 Air filter (CAL block)
Check the element of the air filter (CAL block) for dirt. If the element is dirty, detach
the air tube and replace the filter with a new air filter (Part No. PF010001000).
Note: Install the air filter with its hole (part A) facing up.
WARNING
To prevent the body from injury which can be caused by accidental
activation of the machine, turn off the power of the machine before
following the operation above.
Air tube
Part A