4.2.6.3.9 2 screws on the holding circuit not tightened (screws at 10 & 3; screw at 17 is
tightened).
a.) With nozzles 1235
ACT
NOM
in the vicinity of the loose
screws
Holding circuit < nominal
Loose Screws
in the vicinity of the
loose screws
open < nominal
closed < nominal

Service manual vacuum check with closed nozzles
Page
107 from 136
b.) With nozzles 1069
NOM
ACT
in the vicinity of the loose
screws
Holding circuit < nominal
Loose Screws
in the vicinity of the
loose screws
open < nominal
closed < nominal

Service manual vacuum check with closed nozzles
Page
108 from 136
4.2.7 Vacuumtests on C&P20p / C&P20m2 heads (vacuum pump)
In order to provide guidance when troubleshooting, a number of different modifications were
made to a CP20p head and vacuum tests were then carried out with type 4235 open nozzles
(calibration nozzles) and type 4069 closed (red) nozzles, and the results were compared.
For the sake of clarity, only the first 8 measurements that were taken are shown
here.
The modifications were always carried out on segment 1.
.
4.2.7.1 Measurements without any modifications (NOMINAL values)
a.) with type 4235 nozzles
NOMINAL