00196101-04_Serviceanleitung Vakuumtest 08-2018_D-E - 第126页
Service manual vacuum check with closed nozzles Page 126 fr om 136 4.3.2.2 Ov erview of pos sibl e caus es and ef fects Table w ith reference v alues : Head Type Vacuum values wit h calibr ation noz zle Open Close d Hold…

Service manual vacuum check with closed nozzles
Page
125 from 136
b.) With type 2069 closed nozzles
NOMINAL

Service manual vacuum check with closed nozzles
Page
126 from 136
4.3.2.2 Overview of possible causes and effects
Table with reference values:
Head Type
Vacuum values with
calibration nozzle
Open
Closed
Holding
CPP
Venturi
2057
ca. -500 mbar
ca. -850 mbar
-50 to -60 mbar

Service manual vacuum check with closed nozzles
Page
127 from 136
4.3.2.3 Measurements with modifications
4.3.2.3.1 Measurement with filter disk covered (soiled).
a.) With type 2057 nozzles
b.) With type 2069 nozzles
ACT
Holding circuit > nominal.
Open value > nominal
NOM
NOM
ACT
No features or only
slight features
No features or only
slight features