Service manual vacuum check with closed nozzles Page 90 fr om 136 4.2.5 .3.6 Hole (passage to t he star) for the holding vacuum on segment 1 soil ed. a.) W ith type 1235 no zzles b.) W ith type 1069 no zzles NOM AC T AC …

Service manual vacuum check with closed nozzles
Page
89 from 136
4.2.5.3.5 Measurement with small hole in silicone hose.
a.) With type 1235 nozzles
b.) With type 1069 nozzles
No features
Open value < nominal
Closed value < nominal
ACT
ACT
NOM
NOM
Holding circuit < nominal
No features

Service manual vacuum check with closed nozzles
Page
90 from 136
4.2.5.3.6 Hole (passage to the star) for the holding vacuum on segment 1 soiled.
a.) With type 1235 nozzles
b.) With type 1069 nozzles
NOM
ACT
ACT
Holding circuit < nominal
Holding circuit < nominal
NOM
No features
No features

Service manual vacuum check with closed nozzles
Page
91 from 136
4.2.5.3.7 Hole for the pressure air in holding circuit on segment 1 soiled.
a.) With type 1235 nozzles
b.) With type 1069 nozzles
ACT
Holding circuit < nominal
Open value < nominal
Closed value < nominal
NOM
ACT
Holding circuit < nominal
Open value < nominal
Closed value < nominal
NOM