Service manual vacuum check with closed nozzles Page 92 fr om 136 4.2.5 .3.8 Hole for the vacuum in h olding circuit on segment 1 soiled. a.) W ith type 1235 no zzles b.) W ith type 1069 no zzles AC T AC T Holding c ircu…

100%1 / 136
Service manual vacuum check with closed nozzles
Page
91 from 136
4.2.5.3.7 Hole for the pressure air in holding circuit on segment 1 soiled.
a.) With type 1235 nozzles
b.) With type 1069 nozzles
ACT
Holding circuit < nominal
Open value < nominal
Closed value < nominal
NOM
ACT
Holding circuit < nominal
Open value < nominal
Closed value < nominal
NOM
Service manual vacuum check with closed nozzles
Page
92 from 136
4.2.5.3.8 Hole for the vacuum in holding circuit on segment 1 soiled.
a.) With type 1235 nozzles
b.) With type 1069 nozzles
ACT
ACT
Holding circuit < nominal
Holding circuit < nominal
Open value < nominal
Closed value < nominal
NOM
NOM
No features
Service manual vacuum check with closed nozzles
Page
93 from 136
4.2.5.3.9 2 screws on the holding circuit not tightened (screws at 10 & 3; screw at 17 is
tightened).
a.) With type 1235 nozzles
ACT
in the vicinity of the loose
screws
Holding circuit < nominal
NOM
Loose Screws
in the vicinity of the
loose screws
open < nominal
closed < nominal