00193786-02 - 第111页
S I P L A C E G EM S W V e r s i on G EM 505 . 03 SP 1 H O S T I n t e r f a c e M anua l ©S i e m en s A G, a ll r i gh t s r e s e r v ed page 111 o f 241 I f t he Ho s t r eque s t s t he li m i t s f o r a s pe c i f…

SIPLACE GEM SW Version GEM 505.03 SP1 HOST Interface Manual
Page 110 of 241 ©Siemens AG, all rights reserved
4.4.34 S2F48 - Variable Limit Attributes Send{XE "S2F48"}
S2F48 * H <- E
<L
<L [2]
<U4 VID> * Variable ID
<L [4]
<A UNITS> * Units of Measure
<LIMITMIN> * Minimum Limit
<LIMITMAX> * Maximum Limit
<L * Up to 7 Possible
<L [3]
<B [1] LIMITID> * Limit ID
<UPPERDB> * Upper Deadband
<LOWERDB> * Lower Deadband
>
...
>
>
>
...
> .
The Equipment sends this message in response to a Host S2F47 and reports the
characteristics of limits for specified variables. In response to a request from the Host
for all limits for all variables, only variables with limits defined are reported. If the Host
requests specific variables which are not eligible for limits monitoring, the following
message will be reported for that variable:
S2F48 * H <- E
<L
<L [2]
<U4 VID> * Variable ID
<L> * Not eligible for Limits
>
...
> .

SIPLACE GEM SW Version GEM 505.03 SP1 HOST Interface Manual
©Siemens AG, all rights reserved page 111 of 241
If the Host requests the limits for a specific variable which is eligible for limits monitoring
but does not have any limits defined, this variable will be reported as follows:
S2F48 * H <- E
<L
<L [2]
<U4 VID> * Variable ID
<L [4]
<A UNITS> * Units of Measure
<LIMITMIN> * Minimum Limit
<LIMITMAX> * Maximum Limit
<L> * No Limits Defined
>
>
...
> .

SIPLACE GEM SW Version GEM 505.03 SP1 HOST Interface Manual
Page 112 of 241 ©Siemens AG, all rights reserved
4.5 Stream 3
not used