SIPLACE GEM SW Version GEM 505.03 SP1 HOST Interface Manual
©Siemens AG, all rights reserved page 129 of 241
4.8.19 S6F22 - Request Annotated Report Data
{XE "S6F22"}S6F22 * H<-E, Multiblock
<L
<L [2]
<U4 VID> * VID - Variable ID
<V>
>
...
> .
The Equipment sends the Annotated Report.
If no Report is defined for the RPTID in S6F21, S6F22 has the following special error
format:
S6F22 * H<-E
<L> .
4.8.20 S6F23 - Request Spooled {XE "S6F23"}
S6F23 W * H -> E
<U1 RSDC> .
The Host sends this message to start the transfer of spooled messages from the
Equipment to the Host, or to delete the contents of the spool file, depending on the value
of RSDC.
When the Host requests the spooled messages (RSDC is zero), the Equipment will send
messages according to EC "{XE "MaxSpoolTransmit"}MaxSpoolTransmit". All
messages are sent from oldest to newest, and once the message is successfully sent, it
is removed from the spool. If MaxSpoolTransmit is zero, all messages will be sent one at
a time until the last message has been delivered. If MaxSpoolTransmit is set to a non-
zero value, the Equipment will send the lesser of MaxSpoolTransmit or messages left in
spool. If in this case the Equipment sends MaxSpoolTransmit messages, and messages
remain in the spool, the Equipment will wait for another S6F23 to deliver the next
messages.
If the Host sends S6F23 with RSDC set to one, this will be interpreted by the Equipment
as a request to purge the spool.
RSDC Description
0 Transmit spooled messages.
1 Purge spooled messages
SIPLACE GEM SW Version GEM 505.03 SP1 HOST Interface Manual
Page 130 of 241 ©Siemens AG, all rights reserved
4.8.21 S6F24 - Request Spooled Data Acknowledge{XE
"S6F24"}
S6F24 * H <- E
<B [1] RSDA> .
Equipment acknowledges the Host's request to either purge spooled messages or send
spooled messages to the Host.
RSDA Description
0x00 Normal. Equipment will start to send spooled
data or optionally purge the spool. Action
performed will depend on value for RSDC in
S6F23.
0x02 Denied. Spooled data does not exist.
SIPLACE GEM SW Version GEM 505.03 SP1 HOST Interface Manual
©Siemens AG, all rights reserved page 131 of 241
4.9 Stream 7
Stream 7 is provided for Process Program Management. This function will be
implemented in a later stage.