00193786-02 - 第171页
S I P L A C E G EM S W V e r s i on G EM 505 . 03 SP 1 H O S T I n t e r f a c e M anua l ©S i e m en s A G, a ll r i gh t s r e s e r v ed page 171 o f 241 V I D C l ass Fo rma t Name a nd Descr ip t ion 1002015 SV U4 {…

SIPLACE GEM SW Version GEM 505.03 SP1 HOST Interface Manual
Page 170 of 241 ©Siemens AG, all rights reserved
VID Class Forma
t
Name and Description
State Model.
1 = Equipment Off-Line
2 = Attempt On-Line
3 = Host Off-Line
1002056 SV A
{ XE OPERATORCMDINRMOTESTATE
}OPERATORCMDINRMOTESTATE
The last command issued by the Operator while the
Control state is „Remote“.
An empty text indicates that there was no operator
command in remote state since the last start of the
SIPLACE.
1002057 SV U1
{ XE CONTROLMODE }CONTROLMODE
The actual control mode at the SIPLACE. This SV
indicates which software system is allowed to
download placement programs.
1 = none
2 = the „GEM-Host“
3 = the line computer (LCU)
4 = SIPLACE Pro
Process State Model
1002011 SV U1
{ XE PROCESSSTATE }PROCESSSTATE.
The current Process State.
0 = Machine Initialization
1 = Single Function
2 = Processing
1002012 SV U1
{ XE PREVIOUSPROCESSSTATE
}PREVIOUSPROCESSSTATE.
The Process State in effect before the most recent
transition to the current Process State.
0 = Machine initialization
1 = Single Function
2 = Processing
Alarm Management
1002013 SV U4
{ XE ALARMID }ALARMID.
The ALID of the most recent Alarm transition.
1002014 SV U1
{ XE ALARMSTATE }ALARMSTATE.
The Alarm State now in effect for the most recently
transitioned alarm.
0 = Alarm transitioned OFF
1 = Alarm transitioned ON

SIPLACE GEM SW Version GEM 505.03 SP1 HOST Interface Manual
©Siemens AG, all rights reserved page 171 of 241
VID Class Forma
t
Name and Description
1002015 SV U4
{ XE ALARMSERIAL }ALARMSERIAL.
The sequence number of the most recent alarm
change (going on or going off). This number starts at
zero at power-up and increments by one for each
alarm transition which occurs.
1002016 DV A[0-40]
{ XE ALARMTEXT }ALARMTEXT.
The Alarm Text (ALTX) for the most recently
transitioned Alarm.
1002018 EC U1
{ XE CONFIGALARMS }CONFIGALARMS.
An EC which controls which Alarm Report message
this Equipment will send.
0 = S5F1
1 = S5F71
2 = S5F73
1002019 EC U1
{ XE WBITS5}WBITS5.
An EC which controls the W-Bit setting used when
sending Alarm Reports (S5F1, S5F71, or S5F73).
0 = W-Bit not set
1 = W-Bit set
1002020 SV L
{ XE ALARMSENABLED }ALARMSENABLED.
A list of all Alarms which are currently enabled.
Format as follows:
<L
<U4 ALID>
...
>
1002021 SV L
{ XE ALARMSSET }ALARMSSET.
A list of all Alarms which are currently in the SET (on)
state. Format as follows:
<L
<U4 ALID>
...
>
Time and date
1002022 SV A
{ XE CLOCK }CLOCK.
The Equipment's current Date and Time in the
following format: YYYYMMDDhhmmsscc.
YYYY = year
MM = month

SIPLACE GEM SW Version GEM 505.03 SP1 HOST Interface Manual
Page 172 of 241 ©Siemens AG, all rights reserved
VID Class Forma
t
Name and Description
DD = day
hh = hours
mm = minutes
ss = seconds
cc = centiseconds
1002023 SV A
{ XE TIME }TIME.
The Equipment's current date and time. Format is
described in the variable GEMTIMEFORMAT (VID
1002065). It may be either
YYYYMMDDhhmmsscc OR YYMMDDhhmmss
YY(YY) = year
MM = month
DD = day
hh = hours
mm = minutes
ss = seconds
(cc = centiseconds)
Terminal Service
1002034 EC U1
{ XE WBITS10}WBITS10.
An EC which controls the W-Bit setting used when
sending S10F1.
0 = W-Bit not set
1 = W-Bit set
Data Collection
1002030 SV U4
{ XE PREVIOUSCEID }PREVIOUSCEID.
The CEID of the most recent Collection event which
has occurred.
1002031 EC BOOL
{ XE RPTYPE }RPTYPE.
This EC controls some aspects of the format of Event
Reports sent by this Equipment.
FALSE = Normal Event Reports
TRUE = Annotated Event Reports
1002032 EC U1
{ XE CONFIGEVENTS }CONFIGEVENTS.
An EC which controls some aspects of the Event
Reports sent by this Equipment.
0 = S6F9 or S6F3
1 = S6F11 or S6F13
1002033 EC U1
{ XE WBITS6}WBITS6.
An EC which controls the W-Bit setting used when