00193786-02 - 第182页

S I P L A C E G EM S W V e r s i on G EM 505 . 03 SP 1 H O S T I n t e r f a c e M anua l P age 182 o f 241 ©S i e m en s A G, a ll r i gh t s r e s e r v ed V I D C l ass Fo rma t Name a nd Descr ip t ion < L < L …

100%1 / 241
SIPLACE GEM SW Version GEM 505.03 SP1 HOST Interface Manual
©Siemens AG, all rights reserved page 181 of 241
VID Class Forma
t
Name and Description
It is calculated by subtracting the measured distance
between the nozzle and the upper edge of the
transport conveyor from the HEIGHTHEADx value.
An empty list indicates an error.
For a detailed description of the data item see 4.2
Data Item Dictionary“.
1312006
1412006
2312006
2412006
SV L
{ XE VACUUMDATAx}VACUUMDATA1
VACUUMDATA2
VACUUMDATA3
VACUUMDATA4
Vacuum measurements from the last reference run on
head x. Valid only after reference run.
<L
<L
<I4 open_nozzle> [mbar]
<I4 closed_nozzle> [mbar]
<I4 cubic_nozzle> [mbar]
<I4 not_cubic_nozzle> [mbar]
<I4 tol_dirty_nozzle> [mbar]
<I4 tol_leaky_nozzle> [mbar]
>
.....
>
<I4 closed_nozzle> is not valid for TwinHead
The first element in this list refers to segment 1, the
second to segment 2, and so on.
tol_dirty_nozzle and tol_leaky_nozzle are currently
not used.
An empty list indicates an error.
For a detailed description of the data item see 4.2
Data Item Dictionary“.
1312007
1412007
2312007
2412007
SV L
{ XE SEGMENTINFOx}SEGMENTINFO1
SEGMENTINFO2
SEGMENTINFO3
SEGMENTINFO4
Summation of information per segment.
SIPLACE GEM SW Version GEM 505.03 SP1 HOST Interface Manual
Page 182 of 241 ©Siemens AG, all rights reserved
VID Class Forma
t
Name and Description
<L
<L
<I2 CompPickedUp>
<I2 PickUpErrors>
<I2 CompPlaced>
<I2 PlaceErrors>
>
.....
>
The first element in this list refers to segment 1, the
second to segment 2, and so on.
The variable can be linked e.g. to event PCBReady. It
is reseted when a PCB reaches the center conveyor.
For a detailed description of the data item see 4.2
Data Item Dictionary“.
1312008
1412008
2312008
2412008
SV L PLACEINFO1SUB1
PLACEINFO2SUB1
PLACEINFO3SUB1
PLACEINFO4SUB1
{ XE PLACEINFOxSUB1}
Subset of PLACEINFOx variable. Detailed
description see there.
<L
L <
<U4 X-position> [1/1000 mm]
<U4 Y-position> [1/1000 mm]
<F8 Angle> [1/100 degrees]
<U1 ForceIndex>
<A ReferenceDesignator>
<A ComponentName>
<U2 PackageFormNumber>
<U1 PlacementResult>
<I4 PlacementVacuum> [mbar]
<U2 DataValid>
<I4 X-deviation> [1/1000 mm]
<I4 Y-deviation> [1/1000 mm]
<F8 Angle> [1/100 degrees]
SIPLACE GEM SW Version GEM 505.03 SP1 HOST Interface Manual
©Siemens AG, all rights reserved page 183 of 241
VID Class Forma
t
Name and Description
<F8 MaxLeadDev>
<F8 MaxBallDev>
>
....
(for each segment)
... .
>
<U4 X-position>, <U4 Y-position> and <F8 Angle>
are not valid for TwinHead
The first element in this list refers to segment 1, the
second to segment 2 and so on. If a segment was not
in use in the last placement cycle the list for that
segment is left empty.
Miscellaneous
2012013 SV U2
{ XE ERRORTYPE }ERRORTYPE
Type of the most recent error
2 Transport
3 Track error
4 Machine error
5 Miscellaneous
A value of 0 indicates an error.
2012014 SV U2
{ XE GANRTYONERROR }GANTRYONERROR
Gantry associated with the most recent error (1...4)
A value of 0 indicates an error.
2012015 SV U2
{ XE SEGMENTONERROR }SEGMENTONERROR
Segment number associated with the most recent
error (1...12)
A value of 0 indicates an error.
2012016 SV U2
{ XE TRACKONERROR }TRACKONERROR
Track number associated with the most recent error
event
A value of 0 indicates an error.
2012017 SV U2
{ XE ERRORINFO1}ERRORINFO1
Additional information about an error event.
Corresponds to the first parameter of an error