00193786-02 - 第201页

S I P L A C E G EM S W V e r s i on G EM 505 . 03 SP 1 H O S T I n t e r f a c e M anua l ©S i e m en s A G, a ll r i gh t s r e s e r v ed page 201 o f 241 C E I D Na m e De s cr i p t i on 211062 F M _ G U I _ T EX T _…

100%1 / 241
SIPLACE GEM SW Version GEM 505.03 SP1 HOST Interface Manual
Page 200 of 241 ©Siemens AG, all rights reserved
121044
FM_SYSTEMERROR
System error
121045
FM_WRONG_VERSIONS
Different SR and MC version
121046
FM_MAP_GENERAL
Error during mapping
121047
FM_SYSTEM_CONFIG
Error in the system configuration:
Head, sensor system, feeder
location or machine data
121048
FM_DOWNLOAD_NOK
Error while downloading firmware
* Depending on the collection event, some of the status variables <ERRORTYPE>,
<GANTRYONERROR>, <SEGMENTONERROR>, <TRACKONERROR>,
<ERRORINFO1> and <ERRORINFO2> will be updated at each of these software
collection events.
Nozzle Changer
CEID Name Description
211013
FM_PW_SP_UMRUESTEN
Modify head nozzle-changer*
211042
FM_HOEH_PIP_DL_ZU_GROSS
Incorrect nozzle length*
211047
FM_SCAN_PIP_VERSCHMUTZT
Nozzle contaminated or worn-out*
211048
FM_PIP_KONV_NOK
Nozzle configuration is not ok or error
in calibration
211049
FM_GUI_TEXT_PPW_SP_ANZ_G
AR_LEER_ALLG
Not enough empty garages in RV
magazine for returning nozzles
211050
FM_GUI_TEXT_PPW_SP_ANZ_G
AR_VOLL_ALLG
Not enough nozzles in nozzle-
changer magazine for head
211051
FM_GUI_TEXT_PPW_SP_UMRUE
STEN
RV nozzle changer setup changeover
211052
FM_GUI_TEXT_PPW_SP_MODUL
_ENTR_NOK
RV head nozzle changer cannot be
unlocked
211053
FM_GUI_TEXT_PPW_SP_MODUL
_VERR_NOK
RV head nozzle changer cannot be
locked
211054
FM_GUI_TEXT_PPW_VERM_MA
PPW_VERM.MA file not available or
faulty
211056
FM_GUI_TEXT_PPW_AKT_MA
PPW_AKT.MA file not available or
faulty
211057
FM_GUI_TEXT_PPW_SP_Z_SOLL
PO_UEB_ABH
RV nozzle pick-up incomplete (z-pos.
overshot)
211058
FM_GUI_TEXT_PPW_SP_Z_SOLL
PO_N_ER_ABH
RV nozzle pick-up incomplete (z-pos.
not reached)
211059
FM_GUI_TEXT_PPW_SP_Z_SOLL
PO_UEB_ABW
RV nozzle reject incomplete(z-pos.
overshot)
211060
FM_GUI_TEXT_PPW_SP_Z_SOLL
PO_N_ER_ABW
RV nozzle reject incomplete (z-pos.
not reached)
211061
FM_GUI_TEXT_PPW_SP_Z_SOLL
PO_UEB_ABL
RV nozzle returning incomplete (z-
pos. overshot)
SIPLACE GEM SW Version GEM 505.03 SP1 HOST Interface Manual
©Siemens AG, all rights reserved page 201 of 241
CEID Name Description
211062
FM_GUI_TEXT_PPW_SP_Z_SOLL
PO_N_ER_ABL
RV nozzle returning incomplete (z-
pos. not reached)
211063
FM_GUI_TEXT_PPW_SP_PINOLE
_GEZOGEN
Nozzle changer: sleeve in extended
positio
211064
FM_GUI_TEXT_PPW_VAK_ABL
Problem with vacuum reference value
upon returning nozzle
211065
FM_GUI_TEXT_PPW_VAK_ABW
Problem with vacuum reference value
upon rejecting nozzle
211066
FM_GUI_TEXT_PPW_PINOLE_
LEER
Problem returning nozzle: segment
empty
211067
FM_GUI_TEXT_PPW_PINOLE_
VOLL
Problem picking up nozzle: segment
occupied
211068
FM_GUI_TEXT_PPW_ALLE_
PINOLEN_LEER
Problem returning nozzles: all
segments empty
211069
FM_GUI_TEXT_PPW_ALLE_
PINOLEN_VOLL
Problem picking up nozzles: all
segments occupied
* Depending on the collection event, some of the status variables <ERRORTYPE>,
<GANTRYONERROR>, <SEGMENTONERROR>, <TRACKONERROR>,
<ERRORINFO1> and <ERRORINFO2> will be updated at each of these nozzle
changer collection events.
Axis
CEID Name Description
311004 FM_X_N_OBEN Undefined error message
311005 FM_Y_N_OBEN Undefined error message
311006 FM_S_N_OBEN Undefined error message
311007 FM_D_N_OBEN Undefined error message
311011 FM_X_PROG_FEHLER Programmed position of X-axis
outside travel range*
311012 FM_Y_PROG_FEHLER Programmed position of Y-axis
outside travel range*
311013 FM_D_PROG_FEHLER Programmed position of D1 axis
outside travel range*
311015 FM_S_PROG_FEHLER Programmed position of S/Z-axis
outside travel range*
311017 FM_X_TOL_BIT Position control of X-axis does not
work*
311018 FM_Y_TOL_BIT Position control of Y-axis does not
work*
311019 FM_S_TOL_BIT Position control of S-axis does not
work*
SIPLACE GEM SW Version GEM 505.03 SP1 HOST Interface Manual
Page 202 of 241 ©Siemens AG, all rights reserved
CEID Name Description
311021 FM_D_TOL_BIT Undefined error message
311023 FM_X_TIMEOUT 59 X axis: does not reach required
position*
311024 FM_Y_TIMEOUT 60 Y axis: does not reach required
position*
311025 FM_S_TIMEOUT 38 S axis: does not reach required
position*
311026 FM_Z_SP_TIMEOUT 61 SP/Z axis: does not reach
required position*
311027 FM_D_TIMEOUT 8 SP/D axis: does not reach required
position*
311033 FM_Z_SP_TIMEOUT_PROXIMI
TY SWITCH
20 SP/Z axis: top Proximity switch
does not respond*
311040 FM_Z_SP_PROXIMITY
SWITCH_NICHT_FREI
SP/Z axis: top Proximity switch is not
released*
311044 FM_X_POS_PROXIMITY
SWITCH
X axis: Proximity switch for position
monitoring is off*
311045 FM_Y_POS_PROXIMITY
SWITCH
Y axis: Proximity switch for position
monitoring is off*
311046 FM_S_POS_PROXIMITY
SWITCH
S axis: Proximity switch for position
monitoring is off*
311047 FM_Z_SP_POS_PROXIMITY
SWITCH
SP/Z axis: Proximity switch for
position monitoring is off*
311048 FM_D_POS_PROXIMITY
SWITCH
SP/D axis: Proximity switch for
position monitoring is off*
311051 FM_X_ERROR_BIT X axis: Error bit set*
311052 FM_Y_ERROR_BIT Y axis: Error bit set*
311053 FM_S_ERROR_BIT S axis: Error bit set*
311054 FM_Z_SP_ERROR_BIT SP/Z axis: Error bit set*
311055 FM_D_ERROR_BIT SP/D axis: Error bit set*
311058 FM_X_WARTE_DAIN X axis: No DAIN acknowledgment*
311059 FM_Y_WARTE_DAIN Y axis: No DAIN acknowledgment*
311060 FM_S_WARTE_DAIN S axis: No DAIN acknowledgment*
311061 FM_Z_SP_WARTE_DAIN SP/Z axis: No DAIN
acknowledgment*
311062 FM_D_WARTE_DAIN SP/D axis : No DAIN
acknowlegdment*
311086 FM_X_AK_UNG X axis: command currently invalid*
311087 FM_Y_AK_UNG Y axis: command currently invalid*
311088 FM_S_AK_UNG S axis: command currently invalid*
311089 FM_Z_SP_AK_UNG SP/Z axis: command currently
invalid*