SIPLACE GEM SW Version GEM 505.03 SP1 HOST Interface Manual
©Siemens AG, all rights reserved page 229 of 241
Filling Level
CEID Name Description
1711030 FM_FK_TRACK_RUN_LOW_MIN The track will run empty in a few
minutes.
1711031
FM_FK_TRACK_RUN_LOW_VALUE
The track will run empty because
the amount is below the minimum
amount.
1711032 FM_FK_TRACK_RUN_LOW_PER
CENT
The track will run empty because
the amount is at the percentile
minimum.
1711035 FM_FK_TRACK_ISEMPTY_PERC
ENT
The track has been deactivated
because the amount is below the
percentile minimum
1711036 FM_FK_TRACK_INACT_BC The track has been deactivated
because the barcode of one
component is incorrect.
• Depending on the collection event, some of the status variables <ERRORTYPE>,
<GANTRYONERROR>, <SEGMENTONERROR>, <TRACKONERROR>,
<ERRORINFO1> and <ERRORINFO2> will be updated at each of these trolley
collection events.
Miscellaneous
CEID Name Description
2010001 CoverOpen The protective covers was opened 1
2010002 CoverClosed The protective covers was closed 1
2010004 TrackFull Track reset to full
MACHINESIDE <2012022>,
LOCATION <2012035>,
TRACKNUMBER <2012023>
are valid
LOCATION = -1 means that all tracks of
all locations have been refilled
TRACKNUMBER = -1 means that all
tracks of the specified location have
been refilled
1
2010005 TrackEmpty Track set to empty
In the case of a feeder (not MTC)
TRACKNUMBER <2012023>,
SEGMENT <2012026>,
MACHINESIDE <2012022>,
LOCATION <2012035>
are valid
1

SIPLACE GEM SW Version GEM 505.03 SP1 HOST Interface Manual
Page 230 of 241 ©Siemens AG, all rights reserved
2010006 RefRunGantry1 Reference run complete for the gantry 1
axis
1
2010007 RefRunGantry2 Reference run complete for the gantry 2
axis
1
2010008 TableDownload Software downloaded to the table and
<SOFTWAREREVTABLE> will be
updated.
23
2010009 SingleCircuitOmit The machine signals that it found a
single circuit to omit (Ink Punkt)
Variables HEADID (VID 1022030),
GANTRYID (2012028) and
GANTRYDROUPID (2012029)
are valid.
1
2010010 TapeCut1 Tape cut at location 1 1
2010011 TapeCut2 Tape cut at location 2 1
2010015 MachineReStarted SIPLACE station is re-booting 1
2010016 PickupError An Pickup-Error has occured and
<SEGMENT>, <COMPONENTNAME>,
<MASCHINESIDE>, <LOCATION>,
<TRACKNUMBER>, <DIVISION>,
<LEVEL>, <GANTRYID>,
<GANTRYGROUPID> and <HEADID>
will be updated
28
2010017 PlaceError An Place-Error has occured and
<SEGMENT>,
<REFERENCEDESIGNATOR>,
<COMPONENTNAME>, <GANTRYID>,
<GANTRYGROUPID>, <HEADID>,
<PACKAGEFORMNUMBER> and
<PLACEERRORDESCRIPTION> will be
updated
29
2010018 RefRunGantry3 Reference run complete for the gantry 3
axis
1
2010019 RefRunGantry4 Reference run complete for the gantry 4
axis
1
2010033 MTCDownload Software downloaded to the MTC and
<SOFTWAREREVMTC> will be
updated.
23
2010021 PCBstartProc1Conv1 Start of the placement process for the
PCB in the conveyor 1 processing area 1
<GANTRYINFO1>, <GANTRYINFO4>,
<SEGMENTINFO1 >,
<SEGMENTINFO4>
will be resetted.
1
2010022 PCBreadyProc1Conv1 Placement is finished for the PCB in the
conveyor 1 processing area 1.
1
2010023 PCBstartProc2Conv1 Start of the placement process for the
PCB in the conveyor 1 processing area 2
<GANTRYINFO2>, <GANTRYINFO3>,
1

SIPLACE GEM SW Version GEM 505.03 SP1 HOST Interface Manual
©Siemens AG, all rights reserved page 231 of 241
<SEGMENTINFO2 >,
<SEGMENTINFO3>
will be resetted.
2010024 PCBreadyProc2Conv1 Placement is finished for the PCB in the
conveyor 1 processing area 2.
1
2010025 PCBstartProc1Conv2 Start of the placement process for the
PCB in the conveyor 2 processing area 1
<GANTRYINFO1>, <GANTRYINFO4>,
<SEGMENTINFO1 >,
<SEGMENTINFO4>
will be resetted.
1
2010026 PCBreadyProc1Conv2 Placement is finished for the PCB in the
conveyor 2 processing area 1.
1
2010027 PCBstartProc2Conv2 Start of the placement process for the
PCB in the conveyor 2 processing area 2
<GANTRYINFO2>, <GANTRYINFO3>,
<SEGMENTINFO2 >,
<SEGMENTINFO3>
will be resetted.
1
2010028 PCBreadyProc2Conv2 Placement is finished for the PCB in the
conveyor 2 processing area 2.
1
2010029 PickPlaceStartProc1 The machine is starting to pick up and
place components in Processing1 Area.
1
2010030 PickPlaceStopProc1 The Pick/Place process in Processing 1
Area has been interrupted or is finished.
1
2010031 PickPlaceStartProc2 The machine is starting to pick up and
place components in Processing2 Area.
1
2010032 PickPlaceStopProc2 The Pick/Place process in Processing 2
Area has been interrupted or is finished.
1
2010034 TapeCut3 Tape cut at location 3 1
2010035 TapeCut4 Tape cut at location 4 1
Other Error-Events
CEID Name Description
2211001 FM_ABH_KEIN_BE Component not at nozzle after pick-
up
2211002 FM_BEST_KEIN_BE Component not at nozzle before
placement
2211003 FM_ABH_SPURLEER Track empty, no component during
pick-up
2211004 FM_FM_SPURLEER Flatpack magazine is empty
2211005 FM_MHS_CRASH_GEFAHR Second gantry in travel range
2211006 FM_VAK_DELTA_GRENZE_SP RV: intervals open - closed vacuum
values too low