00193786-02 - 第67页

S I P L A C E G EM S W V e r s i on G EM 505 . 03 SP 1 H O S T I n t e r f a c e M anua l ©S i e m en s A G, a ll r i gh t s r e s e r v ed page 67 o f 241 A SER - A l a r m s e r i a l nu m be r F o r m a t: U4 u s ed i…

100%1 / 241
SIPLACE GEM SW Version GEM 505.03 SP1 HOST Interface Manual
Page 66 of 241 ©Siemens AG, all rights reserved
3 = Message to long (more than 160 char)
4 - 63 reserved
used in : S10F2, S10F4, S10F6, S10F10
ALCD - Alarm code byte
Format: B[1]
bit 8 = 1 means alarm set
bit 8 = 0 means alarm cleared
bit 7-1 is alarm category
0 = not used
1 = Personal safety
2 = Equipment safety
3 = Parameter control warning
4 = Parameter control error
5 = Irrecoverable error
6 = Equipment status warning
7 = Attention flags
8 = Data integrity
>8 = Other categories
9 - 63 reserved
used in: S5F1, S5F6, S5F8
ALED - Alarm enable/disable code
Format: B[1]
bit 8 = 1 means enable alarm
bit 8 = 0 means disable alarm
used in: S5F2, S5F4
ALID - Alarm identification
Format: U4
used in: S5F1 S5F2 S5F5, S5F6, S5F8, S5F71, S5F73
ALPY - Alarm priority
Format: U1
used in: S5F71
ALTX - Alarm text
Format: A[40]
used in: S5F1 S5F6, S5F8
Angle - Angle
Format: F8
Angles are measured counterclockwise from the positive X-axis to the positive Y-axis
Units are 1/100 degree.
used in : PLACEINFOx
SIPLACE GEM SW Version GEM 505.03 SP1 HOST Interface Manual
©Siemens AG, all rights reserved page 67 of 241
ASER - Alarm serial number
Format: U4
used in: S5F71
ASTAT - Alarm status
Format: Boolean
used in: S5F71, S5F73
CEED - Collection event enable/disable code
Format: B[1]
False = Disable
True = Enable
CEID - Collection event ID
Format: U4
used in: S2F35, S2F37, S6F3, S6F9, S6F11, S6F13, S6F15, S6F16, S6F17, S6F18
CLOCK - Clock YYYYMMDDhhmsscc
Format A[16]
used in: S5F71, S5F73, CLOCK, PICKUPDATARESETPOINT
closed_nozzle - Vacuum value for a nozzle
vacuum value measured with closed nozzle
Format: I4
Units are mbar
used in : VACUUMDATAx
ClusterName - Name of the actual cluster
Format: A
used in : TRACE_PCB_DATA
CMDA - Command acknowledge code
Format: B[1]
0 = completed or done
1 = command does not exist
2 = cannot perform now
>2 = other equipment specific error
3- 63 reserved
used in: S2F22, S2F28
CompLeft2Place Number of components which were not placed on the actual PCB
Format: I2
used in : GANTRYINFOx
SIPLACE GEM SW Version GEM 505.03 SP1 HOST Interface Manual
Page 68 of 241 ©Siemens AG, all rights reserved
CompPickedUp Number of components which were picked up successfully per
Gantry or Segment since the current PCB reached the center
conveyor.
Format: I2
used in : GANTRYINFOx, SEGMENTINFOx
CompPlaced Number of components which were placed per gantry or segment
since the current PCB reached the center conveyor.
Format:I2
used in : GANTRYINFOx, SEGMENTINFOx
CompChanged new tape / componentcontainer was added during placement
Format:U2
used in: TRACE_ALL_COMPONENTS
CompContainerSize amount of components in the container
In this version CompContainerSize is always = 0
Format:U4
used in: TAPE_INFO
CompBarcode(x) - Barcode of a component
Format: A
Used in : TRACE_ALL_COMPONENTS, TAPE_INFO
ComponentName - Name of a component
Format: A
used in: PLACEINFOx, PICKUPINFOx, TRACE_ALL_COMPONENTS
CoplanarityErrors
Not used ( = 0)
This value is part of PICKUPERRORSLOCx to be compliant to previous versions
Format: U2
CPACK - Command Parameter Acknowledge Code
Format: B[1]
1 = Parameter Name does not exist
2 = Illegal value specified for CPVAL
3 = Illegal format specified for CPVAL
4 = PP not in library
>4 = other equipment specific error
4- 63 reserved
used in: S2F22, S2F28
CPNAME - Command Parameter Name
Format: A
used in: S2F41, S2F42
CPVAL - Command Parameter Value