S I P L A C E G EM S W V e r s i on G EM 505 . 03 SP 1 H O S T I n t e r f a c e M anua l ©S i e m en s A G, a ll r i gh t s r e s e r v ed page 71 o f 241 F o r m a t: U1 D E F A UL T E RR O R 0 FI N I S H E D 1 ( T r a…

SIPLACE GEM SW Version GEM 505.03 SP1 HOST Interface Manual
Page 70 of 241 ©Siemens AG, all rights reserved
1 = Denied. Insufficient space
2 = Denied. Invalid format
3 = Denied. At least one RPTID already defined
4 = Denied. At least one VID does not exist
>4 = Other errors
5 - 63 reserved
used in: S2F34
DSPER Data Sample Period
Format: A
used in: S2F23
EAC - Equipment Acknowledge Code
Format: B[1]
0 = Accept
1 = Denied. At least one constant does not exist
2 = Denied. Busy
3 = Denied. At least one constant out of range
>3 = Other errors
4 - 63 reserved
used in: S2F16
ECDEF - Equipment Constant Default Value
Format:
used in: S2F30
ECMAX - Equipment Constant MaximumValue
Format:
used in: S2F30
ECMIN - Equipment Constant Minimum Value
Format:
used in: S2F30
ECNAME - Equipment Constant Name
Format:
used in: S2F30
ERACK - Enable/Disable Event Report
Format: B[1]
0 = Accept
1 = Denied. At least one CEID does not exist
>1 = Other errors
2 - 63 reserved
used in: S2F38
Errorcode - Result of writing traceability data (bitcoded)
Traceability data are only reliable if errorcode is = 1

SIPLACE GEM SW Version GEM 505.03 SP1 HOST Interface Manual
©Siemens AG, all rights reserved page 71 of 241
Format: U1
DEFAULT ERROR 0
FINISHED 1 (Traceability data are OK)
DUPLICATE PCB IN PROCESS 2
BARCODE DOUBLET 4
INPROCESSIBLE USER ACTION 8
TRACEABILTY ON DURING PROCESS 16
TRACEABILTY OFF DURING PROCESS 32
CANCELLED 64
DATA_LOST 128
ORPHAN 256
RECOVERY 1024
ONLINE EDITING 2048
used in : TRACE_PCB_DATA
FCNID - Function Identification
Format: U1
used in: S2F43, S2F44
FeederAccessesPerPCB – Number of feeder accesses per PCB
Format: U2
used in: PICKUPERRORSLOCx
FeederType - Identifier for a feeder
Format: U2
1 Linear 4.5 mm
2 Linear 9.5 mm
3 Linear 10 mm
4 Linear 14 mm
5 Linear 30 mm
6 0402_0603
7 8 mm tape, electric, 2 x cycle
8 8 mm tape, electric
9 8 mm tape, mechanical, 2 x cycle
10 8 mm tape, mechanical
11 12mm tape "long"
12 16mm tape "long"
14 24mm "Blister" tape
15 32mm "Paper" tape
16 32mm "Blister" tape
17 44mm tape
18 56mm tape
19 8mm tape "long" 4mm manual
29 8mm tape "long" 2mm manual
30 waffle-pack tray, Matrix Tray Changer
56 24mm type III
57 32mm type III

SIPLACE GEM SW Version GEM 505.03 SP1 HOST Interface Manual
Page 72 of 241 ©Siemens AG, all rights reserved
58 44mm type III
59 56mm type III
60 S_G_12_S
61 S_G_16_S
62 S_G_24_S
63 S_G_32_S
64 S_G_44_S
65 S_G_56_S
66 72mm-S tape
79 3x8 mm tape
80 8mm Surftape feeder
81 12mm Surftape feeder
82 24mm Surftape feeder
149 8mm tape „long“ 8mm
150 8mm "Schulz" tape
151 Fimecore
152 Nitto
153 Bulk-Case feeder
used in: PICKUPINFOx
FiducialName - Identifier of a fiduvial
Format: U2
used in: FIDUCIALDATA
Filling_level - Number of components in a division of a matrix tray changer
Format: I4
used in: MTCInfo
FillingLevel - unused always 0
Format U4
used in: TAPE_INFO
ForceIndex - programmed placement force
see chapter 3.5 in the SIPLACE Data Interface for a detailed description.
Format: U1
used in: PLACEINFOx
GANTRYGROUPID – ID of the gantry-group
Format: U2
1 = First gantrygroup in direction of transport
2 = Second gantrygroup in direction of transport
GANTRYID – ID of the gantry
Format: U2
1...4 (see charpter 'Machine Areas')
GRANT6 - Permission to send
Format: B[1]