00193786-02 - 第74页

S I P L A C E G EM S W V e r s i on G EM 505 . 03 SP 1 H O S T I n t e r f a c e M anua l P age 74 o f 241 ©S i e m en s A G, a ll r i gh t s r e s e r v ed L e ng t h - Leng t h o f a pa ck age f o r m Leng t h i s r e …

100%1 / 241
SIPLACE GEM SW Version GEM 505.03 SP1 HOST Interface Manual
©Siemens AG, all rights reserved page 73 of 241
0 = Permission granted
1 = Busy, try again
2 = Not interested
>2 = Other errors
3 - 63 reserved
used in: S6F6
HCACK - Host Command Parameter Acknowledge Code
Format: B[1]
0 = Accept, Command has been performed
1 = Command does not exist
2 = Cannot perform now
3 = At least one parameter is invalid
4 = Acknowledge, command will be performed with completion signaled later by an
event
5 = Rejected. Already in desired condition
6 = control state is not remote
7 = recipe not in library
8 = control mode is not GEM-Host
9 = bad PP-Body
10 - 63 reserved
used in: S2F42
HEADID ID of the head within a gantry
Format: U2
In this version there is only 1 head per gantry. HEADID is always = 1.
HEIGHTHEAD - distance between the head and the transport conveyor
During the reference run, the SIPLACE machines measures the difference between the
upper edge of the transport conveyor and the nozzle on segment 1. The HEIGHTHEAD
is then calculated by subtracting the length of the nozzle on segment 1 form the
measured value. The nozzle length is defined in the machine data. So HEIGHTHEAD is
a relative, not an absolute value.
Format:I4
Units are 1/1000 mm
used in : HEIGHTHEADx
JobName Name of the actual job
Format:A
used in: TRACE_PCB_DATA
LeadCount - Number of lead found during package form measurement
Format: U2
used in: PLACEINFOx
SIPLACE GEM SW Version GEM 505.03 SP1 HOST Interface Manual
Page 74 of 241 ©Siemens AG, all rights reserved
Length - Length of a package form
Length is returned from the vision system. Its the optical length of the package form.
Units are 1/1000 mm
Format: U4
used in: PLACEINFOx
Level - Level in the matrix tray changer
Level 1 is the lowest level in matrix tray changer, level 40 the top most. A value of 0
indicates the manual tray.
Format: I2
used in: PICKUPINFOx
LIMITACK - Acknowledgment code for variable limit attribute set
Format: B[1]
1 = LIMITID does not exist
2 = UPPERDB < LIMITMAX
3 = LOWERDB >LIMITMIN
4 = UPPERDB < LOWERDB
5 = Illegal format specified for UPPERDB or LOWERDB
6 = ASCII value cannot be translated to numeric
7 = Duplicate limit definition for this variable
>7 = Other errors
8 - 63 reserved
used in: S2F46
LIMITID - Limit ID
Format: B[1]
used in: S2F45, S2F46, S2F48
LIMITMAX - maximum limit
Format:
used in: S2F48
LIMITMIN - minimum limit
Format:
used in: S2F48
LOCATION - Group of feeders 1..4
For a detailed description see 1.6 Machine Areas"
Used in LOCATION, PICKUPINFOx, PICKUPERRORSLOCx, TRACKFULL,
TRACKEMPTY
LOWERDB - lower boundary of the deadband for a limit
Format
used in: S2F45, S2F48
SIPLACE GEM SW Version GEM 505.03 SP1 HOST Interface Manual
©Siemens AG, all rights reserved page 75 of 241
LRACK - Limit Report Acknowledge Code
Format: B[1]
0 = Accepted
1 = Denied. Insufficient space
2 = Denied. Invalid format
3 = Denied. At least one CEID link already defined
4 = Denied. At least one CEID does not exist
5 = Denied. At least one RPTID does not exist
>5 = Other errors
6 - 63 reserved
used in: S2F36
LVACK - Variable limit definition acknowledge code
Format: B[1]
1 = Variable does not exist
2 = Variable has no limits capability
3 = Variable repeated in message
4 = Limit value error as desired in LIMITACK
5 - 63 reserved
used in: S2F46
MachineSide - Side of the machine
Format: U1
0 = right side in transport direction
1 = left side in transport direction
MaxBallDev - Maximal ball deviation
MaxBallDev is calculated by the vision system during the optical centering of a package
form. It is calculated over all balls in all ball groups.
Format: F8
Units are 1/1000 mm
used in: PLACEINFOx,
MaxLeadDev - Maximum lead deviation
MaxLeadDev is calculate by the vision system during the optical centering of a package
form. It is calculate over all leads in all lead groups.
Format: F8
Units are 1/1000 mm
used in: PLACEINFOx,
MAX_TIME_TO_STOP - amount of minutes of spooling until a Remote Stop (if
Safe_Spool_Mode is activ)
Format: U4
MDLN - Equipment Model Type
Format: A
used in: S1F2, S1F13, S1F14, S1F65, S1F66