00193786-02 - 第77页
S I P L A C E G EM S W V e r s i on G EM 505 . 03 SP 1 H O S T I n t e r f a c e M anua l ©S i e m en s A G, a ll r i gh t s r e s e r v ed page 77 o f 241 O r t ho Dev - O r t hogona l de v i a t i on F o r m a t: F 8 U…

SIPLACE GEM SW Version GEM 505.03 SP1 HOST Interface Manual
Page 76 of 241 ©Siemens AG, all rights reserved
MHEAD - Message block header associated with block in error
Format: B[16]
used in: S9F1, S9F3, S9F5, S9F7, S9F11
MID - Lot ID
Format: A[16]
used in S2F27
Tower (Number) - A MTC has 2 Towers.
Values 1,2
Used in MTCInfo, TOWER_ID
MTC_number - Number to identify a MTC
This number corresponds to the value of LOCATION
Format: U1
Values 1,2,3,4
Used in MTCInfo
not_cubic_nozzle - Vacuum value for a nozzle
vacuum threshold for melfs, etc.
Format: I4
Units are mbar
used in : VACUUMDATAx
NOZZLE_TYPE: - Number of a nozzle
For a detailed description see „SIPLACE Placement Stations - Data Interface: Chapter
Nozzle Types“.
Format: U4
used in : NOZZLECONFx, NOZZLERETURN,
ONLACK Acknowledge for code for ON-LINE request
Format: B[1]
0 = Accepted
1 = Denied
2 = Equipment already ON-LINE
3 - 63 reserved
used in S1F18
open_nozzle - Vacuum value for a nozzle
vacuum value measured with an open nozzle
Format: I4
Units are mbar
used in : VACUUMDATAx
OpticalErrors - Number of optical errors since last download of a process program
Format: U2
used in: PICKUPERRORSLOCx

SIPLACE GEM SW Version GEM 505.03 SP1 HOST Interface Manual
©Siemens AG, all rights reserved page 77 of 241
OrthoDev - Orthogonal deviation
Format: F8
Units are 1/100 degree
used in : PLACEINFOx
PackageFormNumber - Identifier for a package form
Format: U2
see chapter 9 in the SIPLACE Data Interface ( <pack_form_no>).
used in: PLACEINFOx
PCBBarcode Barcode of the current PCB
Format: A
used in : TRACE_PCB_DATA
PickErrors - Number of pickup errors per segment since the current PCB reached the
corresponding processing conveyor.
Format:I2
used in : SEGMENTINFOx
PickUpErrors - Number of pick-up errors since last download of a process program
Format: U2
used in: PICKUPERRORSLOCx
PickUpResult - Result of the pick up action
Format : U1
0 NOK (default value, should not appear)
1 OK
2 NOK
3 REUSED (picked up in a previous cycle)
used in : PLACEINFOx
PickUpVaccum - Vaccum measured at pick-up position.
PickUpVacuum is measured in the pick up circuit after a component is picked up
Format : I4
Units are mbar
used in : PICKUPINFOx
Pitch_per_lead_group - Distance between leads.
During the optical centering of a package the vision system calculate the average
distance between the leads within a lead group.
Format: I4
used in : PLACEINFOx
PLACEERRORDESCRIPTION – Description of an placement error.

SIPLACE GEM SW Version GEM 505.03 SP1 HOST Interface Manual
Page 78 of 241 ©Siemens AG, all rights reserved
Format : U2
2 : Visionerror
3 : Vacuumerror
4: ComponentSensor - empty Nozzle
5: ComponentSensor - occupied Nozzle
In case of errors 2 and 3 at the same time, a visionerror (2) will be reported
PlaceErrors - Number of place errors per segment since the current PCB reached the
corresponding processing conveyor.
Format:I2
used in : SEGMENTINFOx
PlacementResult - Result of the placement action
Format : U1
1 : Component placed
2 : Component was thrown away, because of an detected error
3: Postponed (the component will be placed within the scope of a later cycle)
used in : PLACEINFOx
PlacementVaccum - Vacuum measured during placement.
Format : I4
PlacementVacuum is measured in the placement circuit before the component is placed.
UNITS are mbar
used in : PLACEINFOx
PPBODY - Process Program Body
Format: A
used in: S7F3, S7F6
PPGNT - Process Program Grant
Format: B[1]
0 = OK
1 = already have
2 = no space
3 = invalid PPID
4 = busy, try later
5 = will not accept
>5 other error
6 - 63 reserved
used in: S7F2
PPID - Process Program ID
Format: A[8]
used in: S2F27, S7F1, S7F3, S7F5, S7F6, S7F17, S7F20
PRTID - Report ID