S I P L A C E G EM S W V e r s i on G EM 505 . 03 SP 1 H O S T I n t e r f a c e M anua l P age 78 o f 241 ©S i e m en s A G, a ll r i gh t s r e s e r v ed F o r m a t : U2 2 : V i s i one rr o r 3 : V a c uu m e rr o r…

SIPLACE GEM SW Version GEM 505.03 SP1 HOST Interface Manual
©Siemens AG, all rights reserved page 77 of 241
OrthoDev - Orthogonal deviation
Format: F8
Units are 1/100 degree
used in : PLACEINFOx
PackageFormNumber - Identifier for a package form
Format: U2
see chapter 9 in the SIPLACE Data Interface ( <pack_form_no>).
used in: PLACEINFOx
PCBBarcode Barcode of the current PCB
Format: A
used in : TRACE_PCB_DATA
PickErrors - Number of pickup errors per segment since the current PCB reached the
corresponding processing conveyor.
Format:I2
used in : SEGMENTINFOx
PickUpErrors - Number of pick-up errors since last download of a process program
Format: U2
used in: PICKUPERRORSLOCx
PickUpResult - Result of the pick up action
Format : U1
0 NOK (default value, should not appear)
1 OK
2 NOK
3 REUSED (picked up in a previous cycle)
used in : PLACEINFOx
PickUpVaccum - Vaccum measured at pick-up position.
PickUpVacuum is measured in the pick up circuit after a component is picked up
Format : I4
Units are mbar
used in : PICKUPINFOx
Pitch_per_lead_group - Distance between leads.
During the optical centering of a package the vision system calculate the average
distance between the leads within a lead group.
Format: I4
used in : PLACEINFOx
PLACEERRORDESCRIPTION – Description of an placement error.

SIPLACE GEM SW Version GEM 505.03 SP1 HOST Interface Manual
Page 78 of 241 ©Siemens AG, all rights reserved
Format : U2
2 : Visionerror
3 : Vacuumerror
4: ComponentSensor - empty Nozzle
5: ComponentSensor - occupied Nozzle
In case of errors 2 and 3 at the same time, a visionerror (2) will be reported
PlaceErrors - Number of place errors per segment since the current PCB reached the
corresponding processing conveyor.
Format:I2
used in : SEGMENTINFOx
PlacementResult - Result of the placement action
Format : U1
1 : Component placed
2 : Component was thrown away, because of an detected error
3: Postponed (the component will be placed within the scope of a later cycle)
used in : PLACEINFOx
PlacementVaccum - Vacuum measured during placement.
Format : I4
PlacementVacuum is measured in the placement circuit before the component is placed.
UNITS are mbar
used in : PLACEINFOx
PPBODY - Process Program Body
Format: A
used in: S7F3, S7F6
PPGNT - Process Program Grant
Format: B[1]
0 = OK
1 = already have
2 = no space
3 = invalid PPID
4 = busy, try later
5 = will not accept
>5 other error
6 - 63 reserved
used in: S7F2
PPID - Process Program ID
Format: A[8]
used in: S2F27, S7F1, S7F3, S7F5, S7F6, S7F17, S7F20
PRTID - Report ID

SIPLACE GEM SW Version GEM 505.03 SP1 HOST Interface Manual
©Siemens AG, all rights reserved page 79 of 241
Format: U4
used in: S2F33, S2F35, S6F3, S6F9, S6F11, S6F13, S5F16, S6F18, S6F19, S6F21
ProdTimeStart Time of production start
Format: A
used in : TRACE_PCB_DATA
ProdTimeEnd Time of production end
Format: A
used in : TRACE_PCB_DATA
Quality - Measurement result of a package form or a fiducial
Quality ranges between 0 and 100. The higher the value, the better the fiducial was
recognized.
Format: U1
used in: PLACEINFOx, FIDUCIALDATA
RCMD - Remote Command
Format: A
used in: SsF21, S2F41
RealNozzleLength - measured nozzle length
The nozzle length is measured during the reference run. It depends on the
HEIGHTHEAD value. So REAL_NOZZLE_LENGTH is not a absolute but a relative
value.
It is calculated by subtracting the measured difference between the nozzle and the upper
edge of the conveyor belt from the HEIGHTHEAD value.
Format: I4
Units are 1/1000 mm
Reference - Referencenumber of a componentbatch
One reference used in TRACE_SINGLE_CIRCUIT points to one component in
TRACE_ALL_COMPONENTS.
Format: U4
ReferenceDesignator - Identifier for a placement position
Format: A
see chapter 5.4 in the SIPLACE Data Interface ( <position_name> in
<placemant_pos_record>).
used in: PLACEINFOx
REPGSZ - Reporting group size
Format: U4
used in: S2F23
RSDA - Request Spool Data Acknowledge
Format: B[1]
0 = OK