00193786-02 - 第81页

S I P L A C E G EM S W V e r s i on G EM 505 . 03 SP 1 H O S T I n t e r f a c e M anua l ©S i e m en s A G, a ll r i gh t s r e s e r v ed page 81 o f 241 4 = S e c onda ry f un c t i on s pe c i f i ed f o r t h i s s …

100%1 / 241
SIPLACE GEM SW Version GEM 505.03 SP1 HOST Interface Manual
Page 80 of 241 ©Siemens AG, all rights reserved
1 = Denied, busy try later
2 = Denied, spooled data does not exist
3 - 63 reserved
used in: S2F24
RSDC Request Spool Data Code
Format: B[1]
0 = Transmit Spooled Massages
1 = Purge Spooled Messages
2 - 63 reserved
SAFE_SPOOL_MODE (EC)
0 = SAFE_SPOOL_MODE is not activ (no SafeSpool-Stop)
1 = SAFE_SPOOL_MODE is activ, SafeSpool-Stop after MAX_TIME_TO_STOP
Minutes of spooling
SEGMENT Number of the segment to pick up or place a component.
Format: U1
Setup Name of the current Setup
Format: A
used in : TRACE_PCB_DATA
SHEAD - Stored header related to the transaction timer
Format: B[10]
used in: S9F9
SingleCircuitName - Name of a singlecircuit on a pcb
Format: A
used in: TRACE_SINGLE_CIRCUIT
SMPLN - Sample number
Format : U4
used in: S6F1
SOFTREV - Software revision code
Format: A[6]
used in: S1F2, S1F13, S1F14, S1F65, S1F66
STIME - Sample time
Format: A[16]
used in: S6F1
STRACK - Spool Stream Acknowledge
Format: B[1]
1 = Spooling not allowed for stream
2 = Stream unknown
3 = Unknown function specified for this stream
SIPLACE GEM SW Version GEM 505.03 SP1 HOST Interface Manual
©Siemens AG, all rights reserved page 81 of 241
4 = Secondary function specified for this stream
used in: S6F44
STRID - Stream ID
Format: U1
used in: S2F43, S2F44
SVID - Status Variable ID
Format
used in: S2F23
SVNAME - Status variable name
Format: A
used in: S1F12
Table Barcode - Barcode of a table
Format: A
used in: Table _ID
TEXT - A single line of characters
Format: A[160]
used in: S10F1, S10F3, S10F5, S10F9
TIAACK - Equipment Acknowledge Code
Format: B[1]
0 = everything correct
1 = too many SVIDs
2 = no more traces allowed
3 = invalid period
4 - 63 reserved
used in; S2F24
TIACK - Time Acknowledge Code
Format: B[1]
0 = OK
1 = Error, not done
2 - 63 reserved
used in; S2F32
TID - Terminal ID
Format: B[1]
0 = single or main terminal
>0 = additional terminals on same equipment
used in: S10F1, S10F3, S10F5
TOTSMP - Total sample to be made
Format: U4
used in: S2F23
TrackNumber - Number of a track
SIPLACE GEM SW Version GEM 505.03 SP1 HOST Interface Manual
Page 82 of 241 ©Siemens AG, all rights reserved
Format: I2
used in: PICKUPINFOx, PICKUPERRORSLOCx
tol_dirty_nozzle - vacuum value
Format: I4
Units are mbar
used in : VACUUMDATAx
tol_leaky_nozzle - vacuum value
Format: I4
Units are mbar
used in : VACUUMDATAx
TRID - Trace Request ID
Format: U4
used in: S2F23 S6F1
UNITS - Units of measure
Format: A
used in: S1F12, S2F30, S2F48
UPPERDB - Upper boundary of the dead-end of a limit
Format:
used in: S2F45, S2F48
Vacuum- Vacuum in the holding circuit.
Format: I4
Vacuum is the measured vacuum in the holding circuit.
Units are mbar
used in: PLACEINFOx, PICKUPINFOx,
VacuumErrors
Number of VacuumErrors.
Used in PICKUPERRORSLOCx (number of vacuum errors only after pickup)
VID - Variable ID
Format:
used in: S1F3, S1F11, S2F13, S2F15, S2F29, S2F30, S2F33, S2F45, S2F46, S6F3,
S6F13, S6F18, S6F22
VLAACK - Variable Limit Attribute Acknowledge Code
Format: B[1]
0 = OK
1 = Limit attribute definition error
2 = Cannot perform now
3 = Other error
4 - 63 reserved
used in: S2F46
Width- Width of a package form