JUKI FX-3R MAINTENANCE GUIDE.pdf - 第62页
FX-3R Maintenance Guide 5-9 Rev. 1.00 <Power tuning procedure> 1) Change the SET/RUN change-over switch g to the “RUN” mode. 2) Set the auto width to “610 mm”. Keep the square button of the operation key i pressed …

FX-3R Maintenance Guide
5-8
Rev. 1.00
XL specification
Figure 5-5-3-5 Sensor Amplifier with XL Specification
<Setting procedure>
1) Change the SET/RUN change-over switch g to the “SET”
mode.
2) Press the operation key i to display the operation mode
setup indication (indication is “0-op”). Press the triangle
button i to set the dark ON (don).
3) Press the operation key i to display the detection function
mode setup indication (1-Fn). Press the triangle button i to
set the standard mode (Stnd).
4) Press the square button of the operation key i to display
the threshold value teaching level setup indication (3-tL)
and press the triangle button i to set “40P”.
5) Press the square button of the operation key i to display
the MODE key setup indication (5-Md). Press the triangle
button i to set the power tuning run mode (PtUn).
6) Press the square button of the operation key i to display
the power tuning target value setup indication (PL). Press
the triangle button i to set “100”.
7) Press the yellow button of the operation key i to display
the external input setup indication (A-rM). Press the triangle
button i to set the teaching without transmission
workpiece (thrU).
c
RUN indicator 1 CH
(Orange)
d Main digital display (Red)
e RUN indicator 2 CH
(Orange)
f Sub-digital display (Green)
i Operation key
h Channel change-over switch
g SET/RUN change-over switch
j Lock lever
Change to the
SET mode.
Figure 5-5-3-6 SET Mode
Figure 5-5-3-7 Operation Mode
Figure 5-5-3-8 Detection
Function Mode
Figure 5-5-3-9 Threshold Value
Teaching Level
Figure 5-5-3-10 MODE Key
Setup
Figure 5-5-3-11 Power Tuning
Target Value
Figure 5-5-3-12 External Input
Setup

FX-3R Maintenance Guide
5-9
Rev. 1.00
<Power tuning procedure>
1) Change the SET/RUN change-over switch g to the “RUN”
mode.
2) Set the auto width to “610 mm”. Keep the square button of the operation key i pressed for 3
sec. or longer to perform the power tuning.
At this time, pay special attention so that a portion between the transport rails does not interfere
with the light emitted from the optical fiber suitable for the amplifier being operated.
Change to the RUN
mode.
Figure 5-5-3-13 RUN Mode

FX-3R Maintenance Guide
5-10
Rev. 1.00
5-6. Replacing the Stopper Cylinder
1) Remove the hexagon nut c. The parts d, e, and f can then be removed.
2) Remove the hexagon nut g securing the cylinder. (Tool: Single-ended wrench, 11-size)
3) Detach the speed controller from the cylinder. (At this time, check what side the speed
controller has been mounted.)
4) When installing a new stopper cylinder, reassemble the components in the order of steps 3) to
1).
At this time, assemble the cylinder so that the orientation of the speed controller is opposite to
that of the stopper tip.
Additionally, assemble the cylinder so that the distance between the end face of the stopper
arm and the end face of the rod becomes that shown in the Figure below.
5) After the components have been reassembled, supply air (0.49 MPa) to check that the stopper
cylinder moves smoothly.
Figure 5-6-1 Stopper Cylinder
Extrusion amount
of the cylinder rod
PA1004514A0
Air cylinder