JUKI FX-3R MAINTENANCE GUIDE.pdf - 第94页

FX-3R Maintenance Guide 8-12 8-3. Replacement Table for Electric Feeder DANGER To prevent any trouble caused by accidental machine start, always shut-down the power before starting the maintenance and adjustment work. 8-…

100%1 / 251
FX-3R Maintenance Guide
8-11
8-2-5. Replacing the Bank PCB
1) Remove the mounting screws to detach the front panel.
2) Disconnect the connectors (cables) from the mechanical bank PCB.
3) Remove the round head screws (8 pcs.) to detach the mechanical bank PCB and replace it with
a new one.
4) Reassemble the components in the reverse order of disassembly.
SL6030692TN
SEMS cap bolt M3×6
40047311
Front panel
40082808
Mechanical bank PCB ASM
SL4030681SC
SEMS cap bolt M3×6
Figure 8-2-5-1 Bank PCB (When Viewed Slantwise from the Lower Portion)
Rev. 1.00
FX-3R Maintenance Guide
8-12
8-3. Replacement Table for Electric Feeder
DANGER
To prevent any trouble caused by accidental machine start, always
shut-down the power before starting the maintenance and
adjustment work.
8-3-1. Overall Drawing (Replacement Table for ETF)
40084841
EF setup cable 1 bracket
assembly
40084666
E_Trolley cover R
40084636
FDC bracket
40084831 - EF IF CBL 26-30 ASM
40084829 - EF IF CBL 16-20 ASM
40084830 - EF IF CBL 21-25 ASM
40084827 - EF IF CBL 6-10 ASM
40084828 - EF IF CBL 11-15 ASM
40084826 - EF IF CBL 1-5 ASM
40084912
ETF trolley assembly
40084911
ETF bank assembly
Figure 8-3-1-1 Overall Drawing
Rev. 1.00
FX-3R Maintenance Guide
8-13
40084914
Bank PCB box assembly
Figure 8-3-1-2 Overall Drawing (From Obliquely downward View Field)