196 E630116 “Visi on System: It is unprescri bed NA K code. NA K16 code” [Cause] Unpr escribed r esponse was sent bac k from VCS. Some pr ogram vers ions are clas hing with each other. [Treatm ent] Please re-ins tall or …

100%1 / 1361
195
Some program versions are clashing with each other.
[Treatment] Please examine the vision data in the production program.
Please see the completion status of the production program.
Please re-load the production program.
Please re-start the application.
Please re-install or version up the application.
Please re-boot your machine.
E630109 “Vision System: It is unprescribed NAK code. NAK9 code”
[Cause] Unprescribed response was sent back from VCS.
Some program versions are clashing with each other.
[Treatment] Please re-install or version up the application.
Please re-boot your machine.
Please contact our technical service dept. for information.
E630110 “Vision System: A physical error of FLASH occurred”
[Cause] Flash memory of VCS is broken.
Flash memory of VCS has not been formatted yet.
[Treatment] Please change IMGCPUs.
E630111 “Vision System: There is not enough space in FLASH”
[Cause] Flash memory of VCS is broken.
Flash memory of VCS has not been formatted yet.
Flash memory of VCS is not enough.
[Treatment] Please change IMGCPUs.
E630112 “Vision System: System error of FLASH occurred”
[Cause] Flash memory of VCS is broken.
Flash memory of VCS has not been formatted yet.
[Treatment] Please change IMGCPUs.
E630113 “Vision System: Current cabinet is UNTITLED”
[Cause] There is a mistake in the Sequence control in the User defined template.
[Treatment] Please re-load the production program.
Please re-start the application.
Please re-boot your machine.
E630114 “Vision System: There are several templates with the same ID”
[Cause] There is a mistake in the Sequence control in the User defined template.
[Treatment] Please re-teach the marks to the machine.
Please re-load the production program.
Please re-start the application.
Please re-boot your machine.
E630115 “Vision System: It is unprescribed NAK code. NAK15 code”
[Cause] Unprescribed response was sent back from VCS.
Some program versions are clashing with each other.
[Treatment] Please re-install or version up the application.
Please re-boot your machine.
Please contact our technical service dept. for information.
196
E630116 “Vision System: It is unprescribed NAK code. NAK16 code”
[Cause] Unprescribed response was sent back from VCS.
Some program versions are clashing with each other.
[Treatment] Please re-install or version up the application.
Please re-boot your machine.
Please contact our technical service dept. for information.
E630117 “Vision System: It is unprescribed NAK code. NAK17 code”
[Cause] Unprescribed response was sent back from VCS.
Some program versions are clashing with each other.
[Treatment] Please re-install or version up the application.
Please re-boot your machine.
Please contact our technical service dept. for information.
E630118 “Vision System: It is unprescribed NAK code. NAK18 code”
[Cause] Unprescribed response was sent back from VCS.
Some program versions are clashing with each other.
[Treatment] Please re-install or version up the application.
Please re-boot your machine.
Please contact our technical service dept. for information.
E630119 “Vision System: It is unprescribed NAK code. NAK19 code”
[Cause] Unprescribed response was sent back from VCS.
Some program versions are clashing with each other.
[Treatment] Please re-install or version up the application.
Please re-boot your machine.
Please contact our technical service dept. for information.
E630120 “Vision System: There is no cabinet file”
[Cause] There is a mistake in the Sequence control in the User defined template.
[Treatment] Please re-teach the marks to the machine.
Please re-load the production program.
Please re-start the application.
Please re-boot your machine.
E630121 “Vision System: The cabinet file already exists”
[Cause] There is a mistake in the Sequence control in the User defined template.
[Treatment] Please re-teach the marks to the machine.
Please re-load the production program.
Please re-start the application.
Please re-boot your machine.
E630122 “Vision System: Failed to open the cabinet file”
[Cause] There is a mistake in the Sequence control in the User defined template.
[Treatment] Please re-teach the marks to the machine.
Please re-load the production program.
Please re-start the application.
Please re-boot your machine.
E630123 “Vision System: An error of reading the cabinet file”
[Cause] There is a mistake in the Sequence control in the User defined template.
197
[Treatment] Please re-teach the marks to the machine.
Please re-load the production program.
Please re-start the application.
Please re-boot your machine.
E630124 “Vision System: An error of writing the cabinet file”
[Cause] There is a mistake in the Sequence control in the User defined template.
[Treatment] Please re-teach the marks to the machine.
Please re-load the production program.
Please re-start the application.
Please re-boot your machine.
E630125 “Vision System: A data error of the cabinet file”
[Cause] There is a mistake in the Sequence control in the User defined template.
[Treatment] Please re-teach the marks to the machine.
Please re-load the production program.
Please re-start the application.
Please re-boot your machine.
E630200 “Vision System: A bass error occurred. Hardware abnormality”
[Cause] IMGCPU is broken.
The program could not be written in the IMGCPU properly.
[Treatment] Please change IMGCPUs.
Please re-write the program in the IMGCPU.
Please re-boot your machine.
E630201 “Vision System: An address error occurred. Hardware abnormality”
[Cause] IMGCPU is broken.
The program could not be written in the IMGCPU properly.
[Treatment] Please change IMGCPUs.
Please re-write the program in the IMGCPU.
Please re-boot your machine.
E630202 “Vision System: A spurious interruption error occurred. Hardware
abnormality”
[Cause] IMGCPU is broken.
The program could not be written in the IMGCPU properly.
[Treatment] Please change IMGCPUs.
Please re-write the program in the IMGCPU.
Please re-boot your machine.
E630203 “Vision System: It is unprescribed ERR code. ERR3 code”
[Cause] Unprescribed error response was sent back from VCS.
Some program versions are clashing with each other.
[Treatment] Please re-install or version up the application.
Please re-boot your machine.
Please contact our technical service dept. for information.
E630204 “Vision System: It is unprescribed ERR code. ERR4 code”
[Cause] Unprescribed error response was sent back from VCS.
Some program versions are clashing with each other.
[Treatment] Please re-install or version up the application.
Please re-boot your machine.