3 − 30 3.6.10 Saving v i sion data This f unction allows you to save the vision data obtained during product ion onto a floppy disk. Select a f ile you want to save onto a floppy disk on the dialog box shown below , and …

100%1 / 1361
3 29
3.6.9 Saving the machine information
This function allows you to compress and save the machine information that is saved
as a file by your operation on the “Production” screen or the Emergency Stop
message onto a floppy disk.
Note: Use this function only if our service person or distributor requests you to do so.
Handle the obtained file as instructed also.
3.6.9.1 Start of the save operation
When you click the <Action> button on the dialog box shown below, the machine
information is saved onto a floppy disk.
Figure 3.6.9.1 Saving the machine information
3.6.9.2 End of the save operation
When the system finishes saving the information, the dialog box displays the
following information.
Figure 3.6.9.2 Dialog box indicating that the system has
finished saving the information
3 30
3.6.10 Saving vision data
This function allows you to save the vision data obtained during production onto a
floppy disk.
Select a file you want to save onto a floppy disk on the dialog box shown below, and
click the <OK> button. The selected file is saved onto a floppy disk.
Figure 3.6.10 “Vision data in FD files” dialog box
3.6.11 Exit
This command executes the shut-down process to quit the system.
See Section 3.4 “Starting up or Terminating the System” for the procedure for shutting
down the system.
Figure 3.6.11 Shut-down confirmation dialog box
CAUTION
If you turn off the machine without performing the shut-down process,
you may not be able to restart the machine. Be sure to perform the
shut-down process to terminate the system.
3 31
3.7 Corrective Action for A Power Failure
When the power supply to a KE-2000 malfunctions, the power monitor function of the
UPS is activated.
If any power is not supplied to the machine for two seconds or longer, or if the system
detects an instantaneous power interruption that has occurred at the VME board, the
system assumes that a power failure has occurred.
If you do not operate the machine for the certain time of period, the machine saves
the production program, production management information, information required to
restart production, and device management information, and perform the shutdown
process.
3.7.1 Process to be performed when a power failure occurs
Step 1. Preparation for the automatic shutdown
When the machine detects a power failure, the following dialog box appears on the
screen.
Figure 3.7.1.1 Dialog box displayed when the machine detects a power failure (1)
Figure 3.7.1.2 Dialog box displayed when the machine detects a power failure (2)
If you do not perform any operation when the screen shown in Figure 3.7.1.1
appears, the screen shown in Figure 3.7.1.2 (2) appears. The machine counts
down the remaining time. When the remaining time reaches “0”, the machine
displays the automatic shutdown dialog box (see Figure 3.7.1.4).
OK: clears the error message
displayed on the screen
.