251 E691002 “Writ ing-in buf fer of flush memory does not get useable” [Cause] ‘W riting-in’ buf fer did not get useable when check ing its s tatus af ter a ‘writing-in’ com m and to flush m em or y was issued. • Flush m…

100%1 / 1361
250
E690028 “Resistance can no be measured. Please check if probe shuts
down properly”
[Cause] The tester overflowed data when measuring the resistance.
The object(component) of the measurement is not contacting the probe.
The contact between the object(component) of the measurement and the
probe is not good.
The resistance of the object(component) of the measurement is exceeding the
measurement range.
The Component Verification is broken.
[Treatment] Please check and see if the object is contacting the probe well. If not, please
adjust the position of the object to contact the probe properly.
Please check the object.
If the error occurs when the contact is good, there is a possibility that the
Component Verification unit is broken. Please contact our technical service
dept. for information.
E690029 “Volume can not be measured. Please check if probe shuts down
properly”
[Cause] The tester overflowed data when measuring the condenser capacity.
The object(component) of the measurement is not contacting the probe.
The contact between the object(component) of the measurement and the
probe is not good.
The resistance of the object(component) of the measurement is exceeding the
measurement range.
The Component Verification is broken.
[Treatment] Please check and see if the object is contacting the probe well. If not, please
adjust the position of the object to contact the probe properly.
Please check the object.
If the error occurs when the contact is good, there is a possibility that the
Component Verification unit is broken. Please contact our technical service
dept. for information.
E690030 “Voltage can not be measured. Please check if probe shuts down
properly”
[Cause] The tester overflowed data when measuring the diode polarity.
The object(component) of the measurement is not contacting the probe.
The contact between the object(component) of the measurement and the
probe is not good.
The resistance of the object(component) of the measurement is exceeding the
measurement range.
The Component Verification is broken.
[Treatment] Please check and see if the object is contacting the probe well. If not, please
adjust the position of the object to contact the probe properly.
Please check the object.
If the error occurs when the contact is good, there is a possibility that the
Component Verification unit is broken. Please contact our technical service
dept. for information.
E691001 “Input/Output buffer status of CCL-48M does not get ready”
[Cause] The input/output buffer status of the backup table counter(CCL-48M) does not get
ready.
Backup table counter is broken.
[Treatment] Please turn off the power supply and re-boot your machine.
If the error occurs even after the re-boot, there is a possibility that the Safety
board is broken. Please contact our technical service dept. for information.
251
E691002 “Writing-in buffer of flush memory does not get useable”
[Cause] ‘Writing-in’ buffer did not get useable when checking its status after a ‘writing-in’
command to flush memory was issued.
Flush memory is broken.
[Treatment] Please turn off the power supply and re-boot your machine.
If the error occurs even after the re-boot, there is a possibility that the Safety
board is broken. Please contact our technical service dept. for information.
E691003 “Deleting cue of flush memory does not get useable”
[Cause] ‘Deleting’ cue did not get useable when checking its status after a ‘deleting’
command to flush memory was issued.
Flush memory is broken.
[Treatment] Please turn off the power supply and re-boot your machine.
If the error occurs even after the re-boot, there is a possibility that the Safety
board is broken. Please contact our technical service dept. for information.
E691004 “WSM(Write State Machine) of flush memory does not get ready”
[Cause] ‘WSM’ did not get ready when checking its status after a command to flush
memory was issued.
Flush memory is broken.
[Treatment] Please turn off the power supply and re-boot your machine.
If the error occurs even after the re-boot, there is a possibility that the Safety
board is broken. Please contact our technical service dept. for information.
E691005 “Write-in voltage range error occurred in flush memory control”
[Cause] An error occurred while checking the ‘Write-in’ voltage status after a command to
flush memory was issued.
The process was aborted since the ‘write-in’ voltage is too low.
Flush memory is broken.
[Treatment] Please turn off the power supply and re-boot your machine.
If the error occurs even after the re-boot, there is a possibility that the Safety
board is broken. Please contact our technical service dept. for information.
E691006 “Write-in error occurred in flush memory control”
[Cause] An error occurred while checking the ‘device protecting’ status after a command
to flush memory was issued.
The process was aborted since the master lock bit, block lock bit, and RP# lock
were detected.
Flush memory is broken.
[Treatment] Please turn off the power supply and re-boot your machine.
If the error occurs even after the re-boot, there is a possibility that the Safety
board is broken. Please contact our technical service dept. for information.
E691007 “Write-in error occurred in flush memory control”
[Cause] An error occurred while checking the ‘Write-in’ status after a command to flush
memory was issued.
An error occurred while writing data in.
Flush memory is broken.
[Treatment] Please turn off the power supply and re-boot your machine.
If the error occurs even after the re-boot, there is a possibility that the Safety
board is broken. Please contact our technical service dept. for information.
252
E691008 “Command sequence error occurred in flush memory control”
[Cause] An error occurred while checking the status after a command to flush memory
was issued.
A command sequence error occurred.
Flush memory is broken.
[Treatment] Please turn off the power supply and re-boot your machine.
If the error occurs even after the re-boot, there is a possibility that the Safety
board is broken. Please contact our technical service dept. for information.
E691009 “Lock Bit Set error occurred n flush memory control”
[Cause] An error occurred while checking the ‘lock bit set’ status after a command to flush
memory was issued.
An error occurred while setting the master/block lock bit.
Flush memory is broken.
[Treatment] Please turn off the power supply and re-boot your machine.
If the error occurs even after the re-boot, there is a possibility that the Safety
board is broken. Please contact our technical service dept. for information.
E691010 “Lock Bit Clear error occurred in flush memory control”
[Cause] An error occurred while checking the ‘lock bit clear’ status after a command to
flush memory was issued.
An error occurred while clearing the lock bit.
Flush memory is broken.
[Treatment] Please turn off the power supply and re-boot your machine.
If the error occurs even after the re-boot, there is a possibility that the Safety
board is broken. Please contact our technical service dept. for information.
E691011 “The check word for the common data of flush memory is
abnormal”
[Cause] The type of the common data that is saved in the flush memory is irregular.
The common data is not saved in the flush memory.
Flush memory is broken.
[Treatment] Please re-start the application.
Please re-install or version up the application.
If the error occurs even after the treatments above were performed, please
contact our technical service dept. for information.
E691012 “The checksum for the common data of flush memory is abnormal”
[Cause] The common data that is saved in the flush memory is irregular.
The common data of flush memory is broken.
Flush memory is broken.
[Treatment] Please re-start the application.
Please re-install or version up the application.
If the error occurs even after the treatments above were performed, please
contact our technical service dept. for information.