260 4. Detailed Explanation of the Recognition Errors of Special Lead Components (Extension Lead Connectors) ‘RES M N LOC_L Index 85 Err Code … ..’ M: Num ber of c om ponents recognized at the sam e tim e N: Phas e num b…

100%1 / 1361
259
3. Detailed Explanation of the Recognition Errors of Standard Lead
Components
‘RES M N Type Index ErrCode …..’
M: Number of components recognized at the same time
N: Phase number for simultaneous component recognition
Type: Component type
QFP, SOP, PLCC, SCTI, SCTB, SCTO, CON, CON2, SOJ, ZCON,
HSOP, SODIMM
Index: Component identification number
Err
Code
.............. Description of an error Assumed cause
1 Side Pos
Bend
A lead is bent. A lead is damaged and bent.
2 Side Num The number of leads is
smaller than that
regulated.
The number of leads you specified is larger than that of the leads
actually located on a component.
A certain lead(s) cannot be detected normally due to its (their)
stains.
Since a lead is not glossy at all, it cannot be detected normally.
3 Side Pos The length of some leads
is abnormal.
This error occurs because one lead is bent, and the position of
its tip is not aligned with that of other leads.
There are substances similar with a lead such as metal fittings
(connector) on both ends of a lead. When such substances
cannot be removed, this error occurs.
There are substances similar with a lead such as metal fittings
(connector) on the body. When such substances cannot be
removed, this error occurs
A scratch or stains of a nozzle reflects light to a tip of a lead, so
the lead is displayed as if its length becomes longer.
4 Side No lead can be detected. This error occurs when the lead detecting window cannot be set
normally due to the stained VCS.
Vision data is not set correctly (the lead pitch you set is quite
different from the actual pitch.)
The displayed lead is too short. (This error occurs more
frequently if the displayed lead is 0.3 mm or shorter on the
standard view of display.)
5 Side Num There are only a few
leads on a component.
This error occurs when almost all leads cannot be detected
normally due to their stains.
This error occurs also when almost all leads are unglossy, so
cannot be detected correctly.
6 Side Num There are too many
leads on a component.
The number of leads you set is smaller than that of leads actually
located on a component.
There are substances similar with a lead such as metal fittings
(connector) on both ends of a lead. When these substances
cannot be removed, this error occurs.
7 Side The lead pitch is
abnormal.
Vision data (lead pitch) is not set correctly.
8 There is no component. A component is not picked correctly.
This error occurs also when the light does not turn on.
9 Side Num There are not enough
leads on a component.
This error occurs when leads of a 0.4-mm-pitch lead component
are not glossy on the standard view of display or when leads of a
0.3-mm-pitch lead component are not glossy on the option-1
view of display.
Side: Side at which the system detected an error
(0: top side, 1: bottom side, 2: left side, 3: right side)
Pos: The lead number on which the system detected an error (from 1)
Num: The number of leads that were detected
Bend: The lead-bending ratio to the lead pitch (%)
RES 1 1 QFP 0 1 10 27.5
Description of the error: The tenth lead located on the top side of a QFP component
whose ID is “0” is bent by 27.5 %.
Example
260
4. Detailed Explanation of the Recognition Errors of Special Lead
Components (Extension Lead Connectors)
‘RES M N LOC_L Index 85 ErrCode …..’
M: Number of components recognized at the same time
N: Phase number for simultaneous component recognition
Index: Component identification number
Err
Code
.............. Description of an error Assumed cause
0 RCnt DCnt There are not enough
leads on a component.
The number of leads is not set correctly on Vision data.
The displayed lead width is narrower than the actual width
because the lead is stained, and cannot be detected correctly.
The lead is not glossy at all, and the displayed lead width is
narrower than the actual width, so it cannot be detected correctly.
1 ~ SubCode
Detail
The internal algorithm
detected an error.
The number of leads is not set correctly on Vision data.
The lead width is not set correctly on Vision data.
The lead length is not set correctly on Vision data.
The actual lead length is shorter than that you set.
The lead edge is not cut straightly.
A lead cannot be displayed clearly due to its stains or oxidation.
The light does not turn on.
The contrast between a lead and its background is low.
There are many leads and many marks or other substances
similar with a lead on a component.
RCnt: total number of leads to be detected
DCnt: number of leads actually detected
SubCode: VCS internal error code
Detail: VCS internal error code detailed information
“SubCode” and “Detail” indicate the VCS internal recognition block or internal evaluation
parameter. These do not show the direct (physical) cause of an error, but are necessary for
analyzing the error. Let us know these numbers when you contact us.
* Error codes other than the above are equivalent with those of standard lead components.
RES 1 1 LOC_L 0 8 5 0 10 9
Description of the error: Only nine leads of a lead component whose ID is “0” (the total
number of leads is 10) were detected.
Example
261
5. Detailed Explanation of the Recognition Errors of Area Array Components
(Whose Outer Side Is To Be Recognized)
‘RES M N Type Index 8 ErrCode …..’
M: Number of components recognized at the same time
N: Phase number for simultaneous component recognition
Type: component type
PBGA, CBGA, LGA
Index: Component identification number
Err
Code
.............. Description of an error Assumed cause
0 The system failed to
detect a ball(s) located
on the top side of the
component perimeter.
This error occurs when the ball detection area on the top side is
not set correctly due to the stains stuck around the top side of
the VCS screen.
This error occurs also when the number of balls detected on the
top side is one-thirds or less of the number you set because a
ball(s) is (are) stained.
1 The system failed to
detect a ball(s) located
on the bottom side of the
component perimeter.
This error occurs when the ball detection area on the bottom side
is not set correctly due to the stains stuck around the bottom side
of the VCS screen.
This error occurs also when the number of balls detected on the
bottom side is one-thirds or less of the number you set because
a ball(s) is (are) stained.
2 The system failed to
detect a ball(s) located
on the left side of the
component perimeter.
This error occurs when the ball detection area on the left side is
not set correctly due to the stains stuck around the left side of the
VCS screen.
This error occurs also when the number of balls detected on the
left side is one-thirds or less of the number you set because a
ball(s) is (are) stained.
3 The system failed to
detect a ball(s) located
on the right side of the
component perimeter.
This error occurs when the ball detection area on the right side is
not set correctly due to the stains stuck around the right side of
the VCS screen.
This error occurs also when the number of balls detected on the
right side is one-thirds or less of the number you set because a
ball(s) is (are) stained.
4 1 The row of balls located
on the top side of the
component perimeter is
not parallel with that on
the bottom side.
An electrode or substance similar with a ball is located on balls of
the top and bottom sides of the component perimeter. When
such substances cannot be removed, this error occurs.
4 2 The row of balls located
on the left side of the
component perimeter is
not parallel with that on
the right side.
An electrode or substance similar with a ball is located on balls of
the left and right sides of the component perimeter. When such
substances cannot be removed, this error occurs.
4 3 The distance between
the ball rows of the top
and bottom sides of the
component perimeter is
abnormal.
The ball pitch is not set correctly.
This error occurs when the system does not detect any ball on
either side, top or bottom, and detects the row of balls located
inside by one row as the ball row located on the component
perimeter.
The system recognized a different BGA component.
4 4 The distance between
the ball rows of the left
and right sides of the
component perimeter is
abnormal.
The ball pitch is not set correctly.
This error occurs when the system does not detect any ball of
either side, left or right, and detects the row of balls located
inside by one row as the ball row located on the component
perimeter.
The system recognized a different BGA component.
RES 1 1 PBGA 0 8 4 3
Description of an error: Abnormal is the distance between the ball rows located on the top
and bottom sides of the perimeter of a PBGA component whose ID is “0”.
Example