KE2010.Instruction Manual.Ver.2.01,Rev.08 - 第1113页

30 Error M essages on t he Vision Centerin g System Error code Message E630001 ViLib Entry : Failed in initializing. E630002 ViLib Entry : Un-initilizing error occurred E630003 ViLib Thread:Driver Failed to get T hread s…

100%1 / 1361
29
Error Messages on Asynchronous Events
Error code Message
E620009 X axis driver alarm
E620010 Y axis driver alarm
E620011 Yc axis driver alarm
E620014 Z axis driver alarm
E620015 Theta axis driver alarm
E620058 The power failure was detected. Re-starting of a system is required. Please re-switch on a
power supply after a shutdown.
30
Error Messages on the Vision Centering System
Error code Message
E630001 ViLib Entry : Failed in initializing.
E630002 ViLib Entry : Un-initilizing error occurred
E630003 ViLib Thread:Driver Failed to get Thread starated
E630010 There is no empty space in the Vision Resource Semaphore
E630011 ViLib Thread: Failed in registration of bass interrupting
E630012 ViLib Thread: Failed to open the serial port.
E630050 ViLib Entry: IPC Send Error(Entry->Thread) occurred
E630051 ViLib Entry: IPC Receive Error(Entry<-Thread) occurred
E630052 ViLib Entry:Error Execute Undefined Command
E630053 ViLib Thread: Undefined ViOS event is requested
E630073 Vision Data: Ball patter has not been set yet
E630074 Camera scale has not been set yet
E630075 The window frame does not fit in the screen
E630081 There is not valid mark within the detecting window
E630100 Vision System: The parameter value is illegal
E630101 Vision System: parameter count is wrong
E630102 Vision System: You tried to register an undefined component or mark
E630103 Vision System: Component ID number is invalid
E630104 Vision System: Undefined command was issued
E630105 Vision System: Recognition conditions are not enough
E630106 Vision System: There is not enough storage of the user defined template
E630107 Vision System: You are ran out of the resources for the general vision component data
E630108 Vision System: The component is not supported as General Vision component
E630109 Vision System: It is unprescribed NAK code. NAK9 code
E630110 Vision System: A physical error of FLASH occurred
E630111 Vision System: There is not enough space in FLASH
E630112 Vision System: System error of FLASH occurred
E630113 Vision System: Current cabinet is UNTITLED
E630114 Vision System: There are several templates with the same ID
E630115 Vision System: It is unprescribed NAK code. NAK15 code
E630116 Vision System: It is unprescribed NAK code. NAK16 code
E630117 Vision System: It is unprescribed NAK code. NAK17 code
E630118 Vision System: It is unprescribed NAK code. NAK18 code
E630119 Vision System: It is unprescribed NAK code. NAK19 code
E630120 Vision System: There is no cabinet file
E630121 Vision System: The cabinet file already exists
E630122 Vision System: Failed to open the cabinet file
E630123 Vision System: An error of reading the cabinet file
E630124 Vision System: An error of writing the cabinet file
E630125 Vision System: A data error of the cabinet file
E630200 Vision System: A bass error occurred. Hardware abnormality
E630201 Vision System: An address error occurred. Hardware abnormality”
E630202 Vision System: A spurious interruption error occurred. Hardware abnormality
E630203 Vision System: It is unprescribed ERR code. ERR3 code
E630204 Vision System: It is unprescribed ERR code. ERR4 code
E630205 Vision System: It is unprescribed ERR code. ERR5 code
E630206 Vision System: It is unprescribed ERR code. ERR6 code
31
E630207 Vision System: It is unprescribed ERR code. ERR7 code
E630208 Vision System: It is unprescribed ERR code. ERR8 code
E630209 Vision System: It is unprescribed ERR code. ERR9 code
E630210 Vision System: Video Synch. Time out error occurred. Hardware abnormality
E630211 Vision System: A time-out error of the serial communication occurred
E630212 Vision System: An error in capturing an image occurred. Hardware abnormality
E630213 Vision System: An error occurred in the internal driver
E630214 Vision System: The running command got a time-out
E630215 Vision System: It is unprescribed ERR code. ERR15 code
E630216 Vision System: It is unprescribed ERR code. ERR16 code”
E630217 Vision System: It is unprescribed ERR code. ERR17 code
E630218 Vision System: It is unprescribed ERR code. ERR18 code
E630219 Vision System: It is unprescribed ERR code. ERR19 code
E630300 ViLib Thread: Other illogical matter occurred
E630301 ViLib Thread: Turnaround time-out occurred
E631010 ViRecog Error: No mark can be found. Please examine the PWB
E631011 ViRecog Error: The mark is touching the frame. Please examine Mark data
E631012 ViRecog Error: The consistency of the marks is too low. Please examine the PWB
E631013 ViRecog Error: Other mark recognition error occurred. Please examine the mark data
E631020 ViRecog Error: The lead is bent. Please examine the component
E631021 ViRecog Error: The position of the lead tip is illegal. Please examine the component
E631022 ViRecog Error: Lead pitch is wrong. Please examine Vision data
E631023 ViRecog Error: Some leads are missing. Please examine Vision data
E631024 ViRecog Error: The number of leads is too large. Please examine Vision data”
E631025 ViRecog Error: Failed to detect leads. Please examine the picking posture
E631026 ViRecog Error: The number of leads is too small. Please examine Vision data
E631027 ViRecog Error: Failed to find lead(s). Please examine Pick position
E631028 ViRecog Error:Mis-recognized the fine pitch lead. Please examine Light conditions
Q631180 There is a similar pattern in the upper part of the template. Would you like to take the
teaching results in?
Q631181 There is a similar pattern in the lower part of the template. Would you like to take the
teaching results in?
Q631182 There is a similar pattern on the left side of the template. Would you like to take the teaching
results in?
Q631183 There is a similar pattern on the right side of the template. Would you like to take the
teaching results in?
Q631184 “The template does not have enough contrast. Would you like to take the teaching results
in
Q631185 The template has no features. Would you like to take the teaching results in?
E631186 The contrast for the entire image is too low. Please modify the conditions and teach again”
Q631200 The light is getting darker. Please clean the light
E631201 The light is too dark. Please clean the light
E631202 The light is not ON. Please examine it