KE2010.Instruction Manual.Ver.2.01,Rev.08 - 第1121页

38 B. CORRECTIVE A CTI ONS E100010 “Fail ed to init iali ze the Window s Socket ” [Cause] A c ritical er ror oc curred while initializing the system. [Treatm ent] Please turn on the power supply of the m achine af ter fi…

100%1 / 1361
37
Error Messages on Self-calibration
Error code Message
E906001 Memory allocation error
E906002 Shared memory open error
E906011 The measured value exceeds the limit. Check the MS parameters set.
E906021 The machine has not zeroed yet.
E906022 The machine is in the servo free state.
E906031 The selected device is not installed on the machine. Re-select another device.
E906041 There is no available head.
E906042 There is no available VCS.
E906043
%s is disable. Selected unit can not measure
E906051 The No. 501 nozzle and 502 nozzles are not assigned to the ATC. Assign the nozzles to
the ATC on the ATC nozzle setup menu which is invoked from the Machine Setup menu.
E906052 The No. 508 nozzle and 507 nozzles are not assigned to the ATC. Assign the nozzles to
the ATC on the ATC nozzle setup menu which is invoked from the Machine Setup menu.
E906061 The machine could not recognize a mark of the calibration jig used for laser alignment.
Check the jig position.
E906062 The machine could not recognize a mark of the calibration jig used for laser alignment.
E906071 The machine could not pick up the calibration jig used for laser alignment. Check to see if
the jig is placed on the calibration block.
E906072 The machine could not pick up the calibration jig used for laser alignment. Check to see if
the jig is placed on the jig station.
E906073 The offset from the jig placement position to the calibration block position exceeds the limit.
Check the MS parameter.
E906074 The position of the calibration jig for used for laser alignment is abnormal. Check the jig
position.
E906075
Calibration jig for VCS has not been picked up. Check that jig is placed on jig station
E906101 An error occurred when the machine detected the height of the laser measurement surface.
E906102 An error occurred during setting of the laser parameter.
E906103 An error occurred during laser measurement (ONCE).
E906104 An error occurred during laser measurement (SWEEP).
E906105 An error occurred when the machine checked to see if there was a component.
E906201 An error occurred at the axis.
E906301
Error has occurred on axis code:%ld
Q907001 Will you set the safe direction of each I/O device ?
Q907002 The machine will terminate self-calibration. Save the settings?
Q907011 The machine has not zeroed yet. Zero the machine?
Q907021 A component cannot be returned. Discard the component?
I908001 Remove a component at ?.
I909001 The No. ? nozzle will be removed.
I909002 The ? will be returned to the jig station.
38
B. CORRECTIVE ACTIONS
E100010 “Failed to initialize the Windows Socket
[Cause] A critical error occurred while initializing the system.
[Treatment] Please turn on the power supply of the machine after finishing everything and
shutting down the machine
If the error occurs even after the rebooting, there is a possibility that a system file
is broken.
Please take a note of the error number and contact our technical service dept. for
information.
E100020 “Failed to initialize OLE. Confirm the OLE Library version”
[Cause] An error occurred while starting the axis control process.
[Treatment] Please turn on the power supply of the machine after finishing everything and
shutting down the machine
If the error occurs even after the rebooting, there is a possibility that a system file
is broken.
Please take a note of the error number and contact our technical service dept. for
information.
E102010 “Fatal system error occurred. Abort the process”
[Cause] A critical error occurred while initializing the system.
[Treatment] Please turn on the power supply of the machine after finishing everything and
shutting down the machine.
If the error occurs even after the rebooting, there is a possibility that a system file
is broken.
Please take a note of the error number and contact our technical service dept. for
information.
E102020 “You tried to start up, before the end of the previous system
program. Exit the system program, and start again”
[Cause] The next main process got started before the main process fully completed.
[Treatment] Please turn on the power supply of the machine after finishing everything and
shutting down the machine.
If the error occurs even after the rebooting, there is a possibility that a system file
is broken.
Please take a note of the error number and contact our technical service dept. for
information.
E102100 “There was a fatal failure while starting the KE-2000 system.
Avoiding the possible damages, the system is going to abort the
process. (error code = %d)”
[Cause] A critical error occurred during the initialization.
The details of the error during the initialization are shown and the system is shut
down.
? : Detailed error code (Hexadecimal display)
0
3F
Failure count in creating flags to manage events
40
Failure count in initializing IPC for internal communication
100
MC starting error.
101
MC starting procedure 1 error
39
102
MC starting procedure 2 error
103
MC starting procedure 3 error
104
MC starting procedure 4 error
105
MC starting procedure 5 error
106
TIME-OUT of driver initialization
5min.
107
TIME-OUT of the main process initialization on the MC side.
200
MC presence check.
401
Failure in creating memory for design value data.
402
Failure in creating memory for MS parameter
403
Failure in creating memory for Mech. Control parameter.
404
Failure in creating memory for Mech-pos.
405
Failure in creating memory for the operation options.
406
Failure in creating memory for Setup data.
407
Failure in creating memory for historical information.
408
Failure in creating memory for error log.
409
Failure in creating memory for the data on the MM side.
40A
Failure in creating memory for the production program file header.
40B
Failure in creating memory for the PWB data.
40C
Failure in creating memory for the Placement data.
40D
Failure in creating memory for the Component data.
40E
Failure in creating memory for the Pick data.
40F
Failure in creating memory for the Mark data.
410
Failure in creating memory for the Extended Mark data.
411
Failure in creating memory for the Vision data.
412
Failure in creating memory for the Optimization data.
413
Failure in creating memory for the Production Management Information.
414
Failure in creating memory for the Adhesive data.
415
Failure in creating memory for the Production Condition.
416
Failure in creating memory for the Station data.
417
Failure in creating memory for the Extended Placement data.
418
Failure in creating memory for the MTC data.
419
Failure in creating memory for the MTS data.
41A
Failure in creating memory for the MSP data.
41B
Failure in creating memory for the CAB list.
41C
Failure in creating memory for the Vision data array.
41D
Failure in creating memory for the Vision Control.
41E
Failure in creating memory for the Extended New Vision data.
41F
Failure in creating memory for the Element GDP.
420
Failure in creating memory for the Element DP.
421
Failure in creating memory for the Extended ADP.
422
Failure in creating memory for the External DP.