43 W109221 “There are some attached nozzl es” Cause] A nozzle which the machine does not recognize is installed. [Treatm ent] Please return the nozzle to ATC m anually . If suc h a nozz le has not been installed on the h…
42
E109110 “Fatal error occurred in constructing axes structure. Abort the
process”
[Cause] An error occurred in the process of creating axis structure that meets the
machine hardware.
[Treatment] Please turn on the power supply of the machine after finishing everything and
shutting down the machine.
If the error occurs even after the rebooting, there is a possibility that a system file
is broken.
Please take a note of the error number and contact our technical service dept. for
information.
E109120 “Fatal error occurred in initializing axes. Abort the process”
[Cause] An error occurred while starting the Axis Control process.
[Treatment] Please turn on the power supply of the machine after finishing everything and
shutting down the machine.
If the error occurs even after the rebooting, there is a possibility that a system file
is broken or that something is wrong with XMP board or other connectors. .
Please take a note of the error number and contact our technical service dept. for
information.
E109130 “Failed to originate, Please retry”
[Cause] An error occurred during the Home returning process.
?
:
Detailed code
-1
:
An error of the axis process
[Treatment] Please turn on the power supply of the machine after finishing everything and
shutting down the machine.
If the error occurs even after the rebooting, there is a possibility that something is
wrong with the axis.
Please take a note of the error number and contact our technical service dept. for
information.
E109210 “Failed to initialize DTS”
[Cause] An error occurred during the Home returning of DTS.
[Treatment] Please turn on the power supply of the machine after finishing everything and
shutting down the machine.
If the error occurs even after the rebooting, there is a possibility of DTS failure, Air
pressure failure, or Feeder knock-pin failure.
Please take a note of the error number and contact our technical service dept. for
information.
E109220 “Error was detected in checking if any nozzles attached”
[Cause] An error occurred while checking the nozzle installation.
[Treatment] Please turn on the power supply of the machine after finishing everything and
shutting down the machine.
If the error occurs even after the rebooting, there is a possibility of the laser
failure or the axis failure.
Please take a note of the error number and contact our technical service dept. for
information.
43
W109221 “There are some attached nozzles”
Cause] A nozzle which the machine does not recognize is installed.
[Treatment] Please return the nozzle to ATC manually.
If such a nozzle has not been installed on the head, there is a possibility that the
laser is too dirty to work properly or that the laser is broken. If so, please clean
the laser.
If such a nozzle still seems to be installed when you perform the Nozzle laser
measurement by Manual control, please take a note of the error number and
contact our technical service dept. for information.
W109230 “Each I/O is moving to the own safe position, OK?”
[Cause] You are informed that actions such as nozzle returning or I/O reset will begin.
[Treatment] As long as you do not see any obstructions against the action, please execute it.
44
E190000 “A system error occurred. Load library”
[Cause] Failed to start an application(teaching).
• Some program versions are clashing with each other.
[Treatment] • Please re-start the application.
• Please re-install or version-up the application.
If the error occurs even after the treatments above were performed, please
contact our technical service dept. for information.
E190001 “A system error occurred. Find resource”
[Cause] Failed to start an application(teaching).
• Some program versions are clashing with each other.
[Treatment] • Please re-start the application.
• Please re-install or version-up the application.
If the error occurs even after the treatments above were performed, please
contact our technical service dept. for information.
E190002 “A system error occurred. Load resource”
[Cause] Failed to start an application(teaching).
• Some program versions are clashing with each other.
[Treatment] • Please re-start the application.
• Please re-install or version-up the application.
If the error occurs even after the treatments above were performed, please
contact our technical service dept. for information.
E190003 “A system error occurred”
[Cause] Failed to start an application(teaching).
• Some program versions are clashing with each other.
[Treatment] • Please re-start the application.
• Please re-install or version-up the application.
If the error occurs even after the treatments above were performed, please
contact our technical service dept. for information.
E190004 “A system error occurred. Timer acquisition”
[Cause] Failed to start an application(teaching).
• Some program versions are clashing with each other.
[Treatment] • Please re-start the application.
• Please re-install or version-up the application.
If the error occurs even after the treatments above were performed, please
contact our technical service dept. for information.
E191000 “A system error occurred. Load library”
[Cause] Failed to start an application(teaching).
• Some program versions are clashing with each other.
[Treatment] • Please re-start the application.
• Please re-install or version-up the application.
If the error occurs even after the treatments above were performed, please
contact our technical service dept. for information.
E191001 “A system error occurred. Find resource”
[Cause] Failed to start an application(teaching).