49 E241001 “Specif ied device cannot be used” [Cause] You could not go into the teaching m ode s ince the device s elected by HOD is not installed or is s et to “not use” . [Treatm ent] Please check the ins tallation set…

100%1 / 1361
48
E240011 “The station is different
[Cause] This error occurs when the side the HOD device is on is wrong when teaching.
[Treatment] Please check and see which device (left or right) to use.
E240012 “Specified position not move”
[Cause] You could not move the axis to the specified position since the axis went out of its
movable range.
[Treatment] Please check and see if the coordinates are correct.
E240013 “The origin point return is non-completion”
[Cause] Home returning has not been complete yet.
[Treatment] Please hit the ORIGIN button to perform the Home returning, and try the process
again.
E240014 “The Left OCC device is set in unused by the setup”
[Cause] The Left OCC device is set to “not use” in the Use unit in Setup.
[Treatment] If the device is available, please set it to “use” in the Use unit in Setup. If not, this
procedure cannot be executed.
E240015 “The Right OCC device is set in unused by the setup”
[Cause] The Right OCC device is set to “not use” in the Use unit in Setup.
[Treatment] If the device is available, please set it to “use” in the Use unit in Setup. If not, this
procedure cannot be executed.
E240016 “The HMS device is set in unused by the setup”
[Cause] The HMS device is set to “not use” in the Use unit in Setup.
[Treatment] If the device is available, please set it to “use” in the Use unit in Setup. If not, this
procedure cannot be executed.
Q240500 “End tracking?”
[Cause] You are asked if to end the tracking process.
[Treatment] If you want to end the process, press ‘Yes’. If not, press ‘No’.
E241000 “Memory allocation error”
[Cause] Failed to save the work area necessary to run a program or to create a window
due to the shortage of memory
[Treatment] Please increase some memory available by exiting unnecessary applications.
49
E241001 “Specified device cannot be used”
[Cause] You could not go into the teaching mode since the device selected by HOD is not
installed or is set to “not use”.
[Treatment] Please check the installation setting (an option of MS parameter) or the use
setting (Use unit of Machine Setup) of the selected device, and reselect a device
available.
E241002 “The station is different
[Cause] You could not go into the teaching mode since the device selected by HOD and
the Pick data specify different stations to use.
[Treatment] Please reselect a correct device.
E241003 “Specified position not move”
[Cause] You could not go into the teaching mode since you could not move to the
specified position with the device selected by HOD.
[Treatment] Please reselect a device that is available to move to the specified position.
E241004 “The input value is illegal (%s)”
[Cause] This is a program error. The specified value in the dialog became an illegal value.
? : A dialog item that is a cause of the error.
[Treatment] Please close the dialog and try again. If the error occurs again even after the retry,
please contact our technical service dept. for information.
E241005 “Index of component data has irregularities (%d)”
[Cause] The index number of the Component data is illegal. There is a possibility that the
production program is broken.
? : The index number of the Component data.
[Treatment] Please examine the production program.
E241008 “Supply of the component is not assign”
[Cause] ‘Component package’ has not been set in the Component data.
[Treatment] Please set ‘Component package’ in the Component data.
E241009 “Centering of the component is no laser”
[Cause] ‘Centering method’ has not been set to Laser centering in the Component data.
[Treatment] Please set ‘Centering method’ to Laser centering in the Component data.
E241010 “Centering of the component is not assign”
[Cause] ‘Centering method’ has not been set in the Component data.
[Treatment] Please specify ‘Centering method’ in the Component data.
E241011 “No pick data”
[Cause] There is no Pick data that is linked to the Component data.
[Treatment] Please examine the production program.
50
E241013 “Component data is incomplete”
[Cause] The Component data is incomplete.
[Treatment] Please complete the Component data.
E241014 “Index of pick data has irregularities. (%d)”
[Cause] The index number of the Pick data is illegal. There is a possibility that the
production program is broken.
? : The index number of the Pick data.
[Treatment] Please examine the production program.
E241015 “Pick data is incomplete”
[Cause] The Pick data is incomplete.
[Treatment] Please complete the Pick data.
E241016 “Setting the nozzle has not been allocated to ATC. Allocate the
nozzle to ATC using TC nozzle setup function when machine setup.
Nozzle no. : %d”
[Cause] The nozzle that is set in the Component data cannot be assigned to ATC.
? : Nozzle No.
[Treatment] Please check the nozzle No. in the Component data. If the nozzle No. is correct,
please assign the nozzle to ATC in the ATC Nozzle Allocation in the Machine
Setup.
E241018 “There is no pick data available”
[Cause] There is no data available in the Pick data linked to.
[Treatment] Please examine the Pick data.
E241020 “There is no input character”
[Cause] There was no character when you hit the Enter key to define characters.
[Treatment] Please enter characters.
E241021 “Input character has irregularities”
[Cause] The input characters were illegal when you hit the Enter key to define the
characters.
[Treatment] Please enter correct characters.
E241022 “Input value exceeds predetermined data range. (Data range : %s - %)”
[Cause] The value when you hit the Enter key to define it exceeded the input range.
? : input range
[Treatment] Please enter a value that is within the input range.
E241023 “Component size is too big”
[Cause] Measurement/Inspection can not be performed since the component’s size is too
big.
[Treatment] Please check the component’s size.
E241024 “The start no. is larger than the end no.
[Cause] The starting component number is larger than the ending component number.