50 E241013 “Component dat a is incomplet e” [Cause] T he Com ponent data is inc om plete. [Treatm ent] Pleas e com plete the Com ponent data. E241014 “Index of pick data has irregul arities. (%d)” [Cause] T he index num …

100%1 / 1361
49
E241001 “Specified device cannot be used”
[Cause] You could not go into the teaching mode since the device selected by HOD is not
installed or is set to “not use”.
[Treatment] Please check the installation setting (an option of MS parameter) or the use
setting (Use unit of Machine Setup) of the selected device, and reselect a device
available.
E241002 “The station is different
[Cause] You could not go into the teaching mode since the device selected by HOD and
the Pick data specify different stations to use.
[Treatment] Please reselect a correct device.
E241003 “Specified position not move”
[Cause] You could not go into the teaching mode since you could not move to the
specified position with the device selected by HOD.
[Treatment] Please reselect a device that is available to move to the specified position.
E241004 “The input value is illegal (%s)”
[Cause] This is a program error. The specified value in the dialog became an illegal value.
? : A dialog item that is a cause of the error.
[Treatment] Please close the dialog and try again. If the error occurs again even after the retry,
please contact our technical service dept. for information.
E241005 “Index of component data has irregularities (%d)”
[Cause] The index number of the Component data is illegal. There is a possibility that the
production program is broken.
? : The index number of the Component data.
[Treatment] Please examine the production program.
E241008 “Supply of the component is not assign”
[Cause] ‘Component package’ has not been set in the Component data.
[Treatment] Please set ‘Component package’ in the Component data.
E241009 “Centering of the component is no laser”
[Cause] ‘Centering method’ has not been set to Laser centering in the Component data.
[Treatment] Please set ‘Centering method’ to Laser centering in the Component data.
E241010 “Centering of the component is not assign”
[Cause] ‘Centering method’ has not been set in the Component data.
[Treatment] Please specify ‘Centering method’ in the Component data.
E241011 “No pick data”
[Cause] There is no Pick data that is linked to the Component data.
[Treatment] Please examine the production program.
50
E241013 “Component data is incomplete”
[Cause] The Component data is incomplete.
[Treatment] Please complete the Component data.
E241014 “Index of pick data has irregularities. (%d)”
[Cause] The index number of the Pick data is illegal. There is a possibility that the
production program is broken.
? : The index number of the Pick data.
[Treatment] Please examine the production program.
E241015 “Pick data is incomplete”
[Cause] The Pick data is incomplete.
[Treatment] Please complete the Pick data.
E241016 “Setting the nozzle has not been allocated to ATC. Allocate the
nozzle to ATC using TC nozzle setup function when machine setup.
Nozzle no. : %d”
[Cause] The nozzle that is set in the Component data cannot be assigned to ATC.
? : Nozzle No.
[Treatment] Please check the nozzle No. in the Component data. If the nozzle No. is correct,
please assign the nozzle to ATC in the ATC Nozzle Allocation in the Machine
Setup.
E241018 “There is no pick data available”
[Cause] There is no data available in the Pick data linked to.
[Treatment] Please examine the Pick data.
E241020 “There is no input character”
[Cause] There was no character when you hit the Enter key to define characters.
[Treatment] Please enter characters.
E241021 “Input character has irregularities”
[Cause] The input characters were illegal when you hit the Enter key to define the
characters.
[Treatment] Please enter correct characters.
E241022 “Input value exceeds predetermined data range. (Data range : %s - %)”
[Cause] The value when you hit the Enter key to define it exceeded the input range.
? : input range
[Treatment] Please enter a value that is within the input range.
E241023 “Component size is too big”
[Cause] Measurement/Inspection can not be performed since the component’s size is too
big.
[Treatment] Please check the component’s size.
E241024 “The start no. is larger than the end no.
[Cause] The starting component number is larger than the ending component number.
51
[Treatment] Please re-enter the starting or ending component number, and make sure that
the ending component number is always larger than the starting component
number.
W241025 “Measurement item is not selected”
[Cause] Measurement cannot be performed since no measurement items are selected.
[Treatment] Please select necessary measurement items.
E241026 “There is not a measurement possible component”
[Cause] As a result of a search by measurement conditions, there is no component that
can be measured.
[Treatment] Please check the measurement(inspection) conditions.
E241028 “There is not a inspection possible component
[Cause] An a result of a search by inspection conditions, there is no component that can
be inspected.
[Treatment] Please check the inspection conditions.
I241200 “A continuous measurement ended”
[Cause] This message appears to inform you the end(interruption) of the continuous
measurement.
[Treatment] Please press the ‘OK’ button.
I241201 “A continuous inspection ended”
[Cause] This message appears to inform you the end(interruption) of the continuous
inspection.
[Treatment] Please press the ‘OK’ button.
Q241300 “Do you interrupt process?”
[Cause] You are asked if to abort the process when the STOP switch is pressed during
the execution of the process.
[Treatment] ‘YES’ button will abort the process.
‘NO’ button will continue the process.
Q241301 “A noz. When calculated from the outline that measured and a noz.
When at present is set up differes. A calculation noz. No. : %3d A
setting noz. No. : %3d | Does it renew a noz.? When a noz. Is
renewed vacuum level is initialized”
[Cause] A nozzle number calculated from the measured component outline and a nozzle
number that is specified in the Component data differs from each other. You are
asked if to perform a nozzle change.
? : A nozzle number calculated from the measured component outline.
?? : A nozzle number that is specified in the Component data