54 E249001 “The origin point return is non-compl etion. Pl ease operate again after completi ng the origin point return” [Cause] T he axis has not yet been returned to home. [Treatm ent] Please perf orm the Return to hom…
53
E241307 “The inspection error occurred. Do you start single inspection?”
[Cause] When a inspection error occurred during the continuous inspection, you are
asked if to perform a single inspection for a component that is a cause of the
error.
[Treatment] ‘YES’ button will take you to the screen where you can perform the a single
inspection for the component.
‘NO’ button will take you to the screen where you can inspect the next
component.
Q241308 “Is the measurement ended?”
[Cause] You are asked if to close the Measurement screen of the single/continuous
measurement.
[Treatment] ‘YES’ button will end the measurement. ‘NO’ button will cancel to end the
measurement and will go back to the Measurement screen.
Q241309 “Is the inspection ended?”
[Cause] You are asked if to close the Examination screen of the single/continuous
inspection.
[Treatment] ‘YES’ button will end the inspection. ‘NO’ button will cancel to end the inspection
and will go back to the Examination screen.
E241500 “There is no verification device”
[Cause] Verification cannot be performed since there is no verification device installed.
[Treatment] Please check the installation of the verification device (an option in MS
parameter).
E241501 “The verification device is an unused unit”
[Cause] Verification cannot be performed since the verification device is set to “not use”.
[Treatment] Please check the use status of the device (the Use unit in the Machine Setup).
E241502 “Supply of the component is no CVS”
[Cause] You are trying to verify a component that is not set to ‘Verification’ in the
Expansion screen in Editor.
[Treatment] Please set necessary items (Expansion screen in the Edit and Component data)
for the Verification.
E241503 “The inspection error occurred”
[Cause] This message appears to inform you that an error occurred during the Verification
single inspection.
[Treatment] Please press ‘OK’ button.
54
E249001 “The origin point return is non-completion. Please operate again
after completing the origin point return”
[Cause] The axis has not yet been returned to home.
[Treatment] Please perform the Return to home with ORIGIN switch.
E249002 “The OCC device is unused. The bank mark recognition is aborted”
[Cause] OCC or OCC2 was set not to “Use” in the Use unit in Setup when performing the
Bank mark recognition.
[Treatment] Please set OCC or OCC2 to “Use” in the Use unit in Setup.
E249003 “The stop key was pressed. The bank mark recognition is aborted”
[Cause] The stop key was pressed while the Bank mark recognition was in operation.
[Treatment] “OK” button will completely abort the Bank mark recognition process.
E249004 “The axis cannot be moved to recognition position. The bank mark
recognition is aborted”
[Cause] An error occurred in the axis traveling.
[Treatment]
E249005 “The bank mark recognition error. The bank mark recognition is
aborted”
[Cause] An error occurred in the Mark recognition by OCC unit.
[Treatment] Please check and see if feederbank is dirty or if something is concealing the
feederbank.
If the mark does not fit in the frame, you need to adjust the mark.
E249006 “MTS power off”
[Cause] The power supply of MTS is off.
[Treatment] Please turn on the power supply of MTS.
E249007 “MTS cannot move because of cover opening”
[Cause] The cover of the machine is open.
[Treatment] Please close the cover.
E249008 “The door of MTS opens”.
[Cause] Failed to draw the MTS tray out since the MTS door was open.
[Treatment] Please close the MTS door.
E249009 “MTS offline”
[Cause] MTS is not online.
[Treatment] Please make MTS online.
55
E249010 “Servo is in the free state. The bank mark recognition is aborted”
[Cause] The axis could not move since the servo was not locked.
[Treatment] Please lock the servo using S-FREE switch.
Q249051 “Feeder bank has descended. Do you want to lift the feeder bank up
and continue the bank mark recognition?
[Cause] The feeder bank had been descended when you tried to perform the Bank mark
recognition.
[Treatment] YES” button will continue the Bank mark recognition process.
NO” button will completely abort the Bank mark recognition process.
I249070 “Set online for MTS”
[Cause] Failed to draw the MTS tray out since the MTS was not online.
[Treatment] Please make MTS online.
I249071 “Please close the door of MTS”
[Cause] Failed to draw the MTS tray out since the MTS door was open.
[Treatment] Please close the MTS door.