58 E291000 “Conveyor already operated, it is not possibl e to operation” [Cause] T he conveyor has already been in operation. [Treatm ent] Please wait for a while and try again. E291001 “The origin point return is non-co…

100%1 / 1361
57
E290007 “The Head device is set in unused by the setup”
[cause] The specified head is set to “not use” in the Use unit in Setup.
[Treatment] If the specified head is available, please set it to “use” in the Use unit in Setup. If
not, this procedure cannot be executed.
E290008 “HW error. Execution is aborted”
[Cause] A requested action to an axis or other hardware got an error. There may be a
possibility of alarm occurrence, servo free, Emergency STOP, etc.
[Treatment] Please try Servo Free unlocking, Home returning, etc.
Q290500 “It is not possible to move to specified position with this device.
Please push ‘No’ when you discontinue ‘Yes’ when the teaching is
started from the current position”
[Cause] You can not move to the previously set coordinates with the device selected by
HOD. You are asked if to resume the teaching from the current position.
[Treatment] If you want to continue the process, press “Yes”. If not, press “No”.
Q290501 “The teaching operation is executed. Please confirm safety. Please
push ‘No’ when you discontinue ‘Yes’ when executing this”
[Cause] You are asked if to perform the safety check since this operation takes axis
traveling.
[Treatment] If you want to continue the process, press ‘Yes’. If not, press ‘No’.
Q290502 “The position cannot be corrected. Please push ‘No’ when you
discontinue ‘Yes’ when correction is not considered and teaching is
executed”
[Cause] You need to correct the coordinates in order to teach the coordinates to the
machine accurately, but the Mark recognition that is necessary for the coordinate
correction failed for some reason. You are asked if to continue the teaching
although the accurate teaching cannot be expected if you continue the process..
[Treatment] If you want to continue the process, press ‘Yes’. If not, press ‘No’.
Q290503 “The mark has already been registered. Do you overwrite?”
[Cause] There is a mark data left, which was registered before. You are asked if to
overwrite the data.
[Treatment] If you want to overwrite the data, press ‘Yes’. If not, press ‘No’.
58
E291000 “Conveyor already operated, it is not possible to operation”
[Cause] The conveyor has already been in operation.
[Treatment] Please wait for a while and try again.
E291001 “The origin point return is non-completion. Please operate again
after completing the origin point return”
[Cause] Home returning has not been complete yet.
[Treatment] Please press the ORIGIN button to perform the Home returning, and try again.
E291002 “The axis cannot be moved to escape point. Execution is aborted”
[Cause] Failed to move the axis to the escape point.
[Treatment] Please check and see if the axis works properly with Manual control.
E291003 “The conveyor cannot be moved. Execution is aborted”
[Cause] The conveyor did not work for some reason.
[Treatment] Please check and see if the conveyor works properly with Manual control.
E291004 “The conveyor became a time-out. Execution is aborted”
[Cause] PWB conveying had a time-out error.
[Treatment] Please check and see if the conveyor works properly with Manual control.
E291005 “The axis cannot be moved. Execution is aborted”
[Cause] The axis could not move for some reason.
[Treatment] Please check and see if the axis works properly with Manual control.
E291006 “The BOC mark data is not set. Operation is aborted”
[Cause] BOC mark was not set in the Board data or the Board data is incomplete.
[Treatment] Please set and complete the board data.
E291007 “The OCC device is set in unused by the setup”
[Cause] The OCC device is set to “not use” in Setup.
[Treatment] If the device is available, set it to “use” in Setup. If not, this operation cannot be
executed.
E291008 “Value is mistake”
[Cause] The value is wrong when you hit the Enter key to define it.
[Treatment] Please check the entered value.
E291009 “Value out of range”
[Cause] The value when you hit the Enter key to define it exceeded the input range.
[Treatment] Please enter a value which is within the input range.
E291010 “Conveyor margin out of range. It is not possible to operation”
[Cause] Failed to take the value in as a margin since there is a too much difference
59
between the conveyor width and the board size in Y direction.
[Treatment] Please adjust the difference between the conveyor width and the board size in Y
direction with a hand knob, then try again.
E291011 “Cannot move conveyor”
[Cause] This error occurs when the conveyor width cannot be adjusted for some reason.
There is a possibility that an obstruction is being detected by a sensor on the
conveyor.
[Treatment] Please make sure that there is no obstruction to be detected by sensors between
the current position and the destination.
E291012 “The BOC mark recognition error [Circuit : %d / %d point]”
[Cause] VCS could not recognize the BOC mark(s).
?:
Circuit number
??:
The Xth BOC mark.
[Treatment] There is a possibility that the BOC mark(s) could not be taught to the machine
properly.
E291013 “The area sensor was detected. Execution is aborted”
[Cause] The process got forcibly aborted since the area sensor detected something.
[Treatment] Please remove the factor that was detected by the sensor.
E291014 “Emergency stopped. Execution is aborted”
[Cause] The process got forcibly aborted since the Emergency STOP occurred.
[Treatment.] Please remove the cause of the Emergency STOP.
E291015 “PWB exist in the entry side center buffer. Please execute retry
after ejection”
[Cause] PWB loading did not succeed since a PWB is staying on the inlet side of the
buffer.
[Treatment] Please take the PWB off the inlet side of the buffer.
E291016 “PWB exist in the exit side center buffer. Please execute retry after
ejection”
[Cause] PWB loading did not succeed since a PWB is staying on the outlet side of the
buffer.
[Treatment] Please take the PWB off the outlet side of the buffer.
E291017 “There is no completed pickup data”
[Cause] The process could not be executed since there is no complete data.
[Treatment] Please input and complete the pickup data.