61 Q291501 “O peration int erruption. Pl ease push ‘No’ w hen di scontinuing. ‘Yes’ w hen conti nuing” [Cause] T he operation was aborted s ince ST OP button was press ed. [Treatm ent] If you w ant continue the oper atio…

100%1 / 1361
60
E291018 “Input string is mistake”
[Cause] Character(s) was wrong when you hit the Enter key to define the caracter(s).
[Treatment] Please re-enter characters.
E291019 “Range is mistake”
[Cause] The value exceeded the input range when you hit the Enter key to define the
value.
[Treatment] Please enter a value which is within the input value.
E291020 “Please check the feeder to trace”
[Cause] No feeders to trace are selected.
[Treatment] Please select a feeder to trace.
E291021 “There is no completed placement data”
[Cause] This process could not be executed since there is no complete placement data.
[Treatment] Please input and complete the placement data.
E291022 “Because the one PWB is not clamped, cannot execute the BOC
alignment”
[Cause] Any PWBs are clamped on the conveyor buffer. If there is no PWB, BOC mark
recognition is not available.
[Treatment] Please load PWB(s) to BOC align.
E291023 “The automatic conveyor width adjustment is set in unused by the
setup”
[Cause] Auto. PWB Width Alignment Control is set to “not use” in Setup.
[Treatment] If Auto. PWB Width Alignment Control is available, please set it to “use” in the
Setup. If not, this operation cannot be executed.
E291024 “The BOC mark data send error [ID : &d]”
[Cause] BOC Mark data could not be sent to VCS.
? : BOC mark ID
[Treatment] Please re-teach the Mark data to the machine.
E291025 “Servo off, it is not possible to operation”
[Cause] Servo is in the free state.
[Treatment] Please perform the Home returning.
Q291500 “The BOC mark recognition error. Please push ‘No’ when
discontinuing. ‘Yes’ when continuing”
[Cause] The BOC mark(s) could not be recognized by VCS.
[Treatment] There is a possibility that the BOC mark(s) could not be taught to the machine
properly.
61
Q291501 “Operation interruption. Please push ‘No’ when discontinuing.
‘Yes’ when continuing”
[Cause] The operation was aborted since STOP button was pressed.
[Treatment] If you want continue the operation, press ‘Yes’. If not, press ‘No’.
Q291502 “The BOC alignment is executed. Please confirm safety. Please
push ‘No’ when discontinuing. ‘Yes’ when continuing”
[Cause] You are asked if to perform the safety check since the operation takes axis
traveling.
[Treatment] If you want to continue the operation, press ‘yes’. If not, press ‘No’.
Q291503 “The BOC alignment is executed. Please confirm safety. Please
push ‘No’ when discontinuing. ‘Yes’ when continuing”
[Cause] You are asked if to perform the safety check since the operation takes axis
traveling.
[Treatment] If you want to continue the operation, press ‘yes’. If not, press ‘No’.
Q291504 “The BOC alignment is executed. Please confirm safety. Please
push ‘No’ when discontinuing. ‘Yes’ when continuing”
[Cause] You are asked if to perform the safety check since the operation takes axis
traveling.
[Treatment] If you want to continue the operation, press ‘yes’. If not, press ‘No’.
Q291505 “Unit is moved to escape point. Please confirm safety.
Please
push ‘No’ when discontinuing. ‘Yes’ when continuing”
[Cause] You are asked if to perform the safety check since the operation takes axis
traveling.
[Treatment] If you want to continue the operation, press ‘yes’. If not, press ‘No’.
Q291506 “Conveyor width is moved. Please remove handknob and PWB from
conveyor. | Please push ‘No’ when discontinuing. ‘Yes’ when
continuing”
[Cause] You are asked if to perform the safety check by removing PWBs and a handknob
from the conveyor since the conveyor width is adjusted.
[Treatment] If you want to continue the operation, press ‘yes’. If not, press ‘No’.
Q291507 “The origin point return of automatic conveyor width adjustment is
non-completion. Continue anyway? Please push ‘No’ when
discontinue. ‘Yes’ when continuing”
[Cause] You are asked if to perform the Home returning of the Auto. PWB Width
Alignment Control since its Home returning has not been complete yet.
[Treatment] If you want to continue the operation, press ‘yes’. If not, press ‘No’.
62
E292000 “No registered data”
[Cause] The following procedures were taken place when the number of the registered
issue of Mark Database is zero.
1. Press [Rename(C)] button or [Delete(D)] button on the Mark Database
Management screen.
2. Press [Replace(A)] button on the Registration Mark Database screen.
3. Press [Copy(C)] button on the Vision Copy screen.
[Treatment] The procedures above can not be performed when there is no registry in the
Mark Database.
E292001 “Please select the mark”
[Cause] 1. Although [Rename (C)] button or [Delete(D)] button screen were pressed on
the Mark Database Management screen, there is no selected mark to be an
object of the action.
2. Although [Copy(C)] button was pressed on the Vision Copy screen, there is no
selected mark to be an object of the action.
[Treatment] Please select a mark to be an object of each action.
E292002 “Registration number was exceeded”
[Cause] As the maximum number of registration is 100, you can not register any new data
in the Mark Database.
[Treatment] Please delete unnecessary marks on the Mark Database Management screen.
E292003 “The mark of the same registration name exists”
[Cause] 1. On the Mark Data name change screen which is shown when pressing
[Rename(C)] button on the Mark Database Management screen, a name
which was entered as “a name after the change” has already been registered
in the Mark Database.
2. When pressing [Add New(N)] button or [Replace(A)] button on the
Registration Mark Database screen, a name which was entered as “a name to
register” has already been registered in the Mark Database.
[Treatment] Please enter the names that have not been registered in the Mark Database yet.
E292004 “Please input the registration name”
[Cause] 1. Although [OK] button was pressed on the Mark Data name change screen that
is shown when pressing [Rename(C )] button on the Mark Database
Management screen, “a name after the change” has not been entered yet.
2. Although [Add new(N)] button or [Replace(A)] button was pressed on the Mark
Database register screen, “a name to register” has not been entered yet.
[Treatment] Please enter a mark name.
E292005 “Please select the registered area”
[Cause] Although [Replace(A)] button was pressed on the Mark Database Registration
screen, there is no selected mark to be an object of the action.
[Treatment] Please select a mark to be an object of overwriting.
Q292501 “The selected mark data is deleted. Is it good?”
[Cause] This message appears in order to confirm you if to delete the data when
pressing[Delete(D)] button on the Mark Database Management screen.
[Treatment] If you want to delete the mark, press [OK] button. If not, press [Cancel] button.
E301000 “Memory allocation error”
[Cause] The working space can not be saved.