KE2010.Instruction Manual.Ver.2.01,Rev.08 - 第1150页

67 E301054 “MTC/MTS can not be connected to 2000 seri es machines at the same time” [Cause] MT C and MT S can not be set at the s ame tim e. [Treatm ent] Please disable one of them . E301055 “An error on axes occurred” […

100%1 / 1361
66
E301046 “Only nozzle No. has been input. Please specify nozzle types”
[Cause] When you entered nozzle No. only, ATC nozzle allocation is not available.
[Treatment] Please enter nozzle types.
E301047 “An error occurred while taking nozzles off. The process is
discontinued”
[Cause] This error occurs when the machine determines that a nozzle is still on the head
despite that the nozzle removal process took place.
[Treatment] If the nozzle is not on the head, the laser might be too dirty to work properly.
Please clean the laser. Also, please check and see if the slide plate can slide
properly or the sensor works properly with Manual control. If the slide plate or the
sensor does not work well, something might be broken. Please take a note of the
error No. and contact our technical service dept. for information.
E301048 “Vacuum Calibration unit position can not be measured”
[Cause] The ATC which is set on the Vacuum Calibration unit can not be measured.
[Treatment] When you need to measure the ATC, please un-allocate then measure it.
E301049 “An error occurred while installing nozzles. [Error occurs] %d
[Error No.] %d [Error info] %d”
[Cause] An error occurred while installing a nozzle when a nozzle change.
?:
A code which tells where the error occurred.
??:
Error code
???:
Error details code
[Treatment] Please take a note of the error No., and contact our technical service dept. for
information.
E301050 “In 2030, Vacuum Calibration can be set for only R1 through R4”
[Cause] In 2030, Vacuum Calibration unit can be set only for R1 through R4.
[Treatment] Please set to ATC of R1 through R4.
E301051 “Vacuum Calibration can be et only for small-diameter nozzles.
(Settable range : 1 - %d)”
[Cause] The Vacuum Calibration unit can not be set other ATC than the ATC of small
nozzles.
?:
The maximum settable ATC number
[Treatment] Please set the unit for the ATC of small nozzles.
E301052 “Any heads have not been specified”
[cause] You did not specify a head to be measured.
[Treatment] Please specify a head to measure.
E301053 “The Changer table can not be installed on the rear side since
MTC/MTS have been selected”
[Cause] You can not use the changer table on the rear side when MTC or MTS is set to
use.
[Treatment] Please disable MTC or MTS when you use the changer table on the rear side.
67
E301054 “MTC/MTS can not be connected to 2000 series machines at the
same time”
[Cause] MTC and MTS can not be set at the same time.
[Treatment] Please disable one of them.
E301055 “An error on axes occurred”
[Cause] An error occurred while axes were traveling.
[Treatment] Please contact our technical service dept. for information.
E301056 “An error on XY axes occurred”
[Cause] An error occurred while XY axes were traveling.
[Treatment] Please contact our technical service dept. for information.
E301057 “An error on Z axis occurred”
[Cause] An error occurred while Z axis was traveling.
[Treatment] Please contact our technical service dept. for information.
E301058” “Specified 508 nozzle has not been assigned yet. Please execute
nozzle assignment”
[Cause] 508 nozzle is necessary to auto-teach MTC shuttle pick position to the machine,
but the 508 nozzle has not been assigned yet..
[Treatment] Please assign the 508 nozzle, then try auto-teaching.
E301059 “It was impossible to learn the height. Please checck out the
vacuum value”
[Cause] An abnormal matter happened while learning the height by vacuum.
[Treatment] Please check and see if the vacuum pressure is correct.
E301060 “DTS/MTS can not be connected to 2000 series machines at the
same time”
[Cause] DTS and MTS can not be set at the same time.
[Treatment] Please disable one of them.
E301061 “Feeder float detector can not be set only out position”
[Cause] You can not use the outer feeder float detectors only.
[Treatment] Please use the inner feeder float detectors only or use all the detectors at once.
Q302000 “Reset I/O?”
[Cause] You are asked if to set each I/O in the safety direction.
[Treatment] “YES” button will sets I/O in the safety direction.
“NO” button will discontinue to exit the Manual control.
68
Q302001 ”Exit machine setup. Set value is saved?”
[Cause] You are asked if to save the parameter that was set in Machine Setup.
[Treatment] “YES” button will save the set value.
“NO” button will not save the set value.
“Cancel” button will cancel your inquiry.
Q302002 “Error has occurred during automatic measurement of nozzle. Do
you interrupt automatic measurement?”
[Cause] An error occurred during the auto. nozzle measurement of ATC nozzle allocation.
You are asked if to abort the following ATC auto. measurement.
[Treatment] “YES” button will abort the auto. measurement.
“NO” button will continue the auto. measurement.
Q302003 ”Return to home has not yet been completed. Return to home?”
[Cause] The axis has not returned to home yet. You are asked if to perform Home
returning.
[Treatment] “YES” button will perform the Home returning, and continue the process.
“NO” button will not perform the Home returning, but continue the process.
Q302004 “Error has occurred during nozzle installation. Move to parking
position?”
[Cause] A nozzle installation error of ATC nozzle allocation occurred. You are asked if to
move the head to the nozzle removal position.
[Treatment] “YES” button will move the head to the nozzle removal position, and continue the
process.
“NO” button will not move the head to the nozzle removal position, but continue
the process.
Q302005 “Extend shuttle?”
[Cause] You are asked if to draw a shuttle out of MTC when teaching the MTC shuttle
pick position to the machine.
[Treatment] “YES” button will draw the shuttle from MTC, and get in the teaching mode.
“NO” button will no draw the shuttle from MTC, but get in the teaching mode.
Q302006 “Do you interrupt automatic measurement?”
[Cause] STOP switch was pressed while nozzle were automatically assigned. You are
asked if to abort the auto. measurement.
[Treatment] “YES” button will abort the auto. measurement.
“NO” button will continue the auto. measurement.
Q302007 “A nozzle is fixed to %s. Do you want to auto-return the nozzle?"
[Cause] With a nozzle on the head, the ? head in the Use unit was changed to “not use”
from “use” You are asked if to return the nozzle to ATC before enabling the
change.
[Treatment] “YES” button will return the nozzle installed on the head.
“NO” button will enable the change with the nozzle on the head. When you
choose “NO”, you need to cancel the nozzle allocation in the ‘ATC nozzle
allocation’.