82 E500205 “Visi on data has not been compl eted” [Cause] T he produc tion can not be star ted since the Vision data of the Production program that is c urrently loaded on the mem ory is incom plete. [Treatm ent] Please …
81
E500101 “Input range has been exceeded. The resumption position of a
placement point is set outside of the possible range”
[Cause] The entered resumption position of a placement point exceeded the input range.
[Treatment] Please enter the value that is under the maximum number of placement points.
E500102 “Input range has been exceeded. (Input range: %ld - %ld)”
[Cause] The input value exceeded the input range.
? - ? : The maximum and minimum values of the input range.
[Treatment] Please enter a value that is within the input range.
E500200 “PWB data has not been completed”
[Cause] The production can not be started since the PWB data of the Production program
that is currently loaded on the memory is incomplete.
[Treatment] Please go to the Production Program Editor and complete the PWB data.
E500201 “Placement data has not been completed”
[Cause] The production can not be started since the Placement data of the Production
program that is currently loaded on the memory is incomplete. However,
‘complete’ here applies only to the placement data that will actually be placed (the
placement data that will be skipped is not included), and production programs
that are considered as ‘incomplete’ in the Production Program Editor may
become ‘complete’ in the production.
[Treatment] Please go to the Production Program Editor and complete the Placement data.
E500202 “Component data has not been completed”
[Cause] The error is likely to happen when starting a production by pressing the START
button on the operation panel. The production can not be started since the PWB
data of the Production program that is currently loaded on the memory is
incomplete.
[Treatment] Please go to the Production Program Editor and complete the PWB data.
E500203 “Pick-up data has not been completed”
[Causes] The production can not be started since the Pick data of the Production program
that is currently loaded on the memory is incomplete. However, ‘complete’ here
applies only to the pick data that will actually be picked (a pick data which is set to
“not use” is not included), and production programs that are considered as
‘incomplete’ in the Production Program Editor may become ‘complete’ in the
production.
[Treatment] Please go to the Production Program Editor and complete the Pick data.
E500204 “Mark data has not been completed”
[Cause] The production can not be started since the Mark data of the Production program
that is currently loaded on the memory is incomplete.
[Treatment] Please go to the Production Program Editor and see the BOC mark setting of the
PWB data and the IC mark setting of the Placement data.
82
E500205 “Vision data has not been completed”
[Cause] The production can not be started since the Vision data of the Production
program that is currently loaded on the memory is incomplete.
[Treatment] Please go to the Production Program Editor and see the Vision data.
E500206 “Teaching of acknowledgment of BOC mark has not been
completed”
[Cause] The Recognition teaching of BOC mark the Production program that is currently
loaded on the memory is incomplete.
[Treatment] Please go to the Production Program Editor and see the Recognition teaching in
the PWB data.
[Remarks
]
Please note that whether the recognition teaching of BOC marks is done or not
will not affect on the completion status of the PWB data.
E500207 “Teaching of acknowledgment of IC mark has not been completed”
[Cause] The Recognition teaching of IC mark the Production program that is currently
loaded on the memory is incomplete.
[Treatment] Please go to the Production Program Editor and see the IC teaching in the
Placement data.
[Remarks
]
In a normal production program, a placement data is considered as ‘incomplete’
when its recognition teaching of IC mark has not been done. There is a possibility
that the production program is broken when the error occurs.
E500208 “The production program breaks”
[Cause] Failed to read in the production program file.
[Treatment] This is a program error. Please make a note of the cause of the error and the
error code, then contact our technical service Dept. for information.
E500210 “Auto. Select exists in the Pick data. Production can not be
executed”
[Cause] [Feed] in the Pick data is set to Auto. Select. The production can not be executed.
[Treatment] You need either to execute the Optimization in the Production Program Editor or
to set pick positions.
E500211 “There is no data which placement is specified”
[Cause] This message appears when the trial shot range is set to ‘specified placement
point’ on the Trial production dialog, but there is no placement data.
[Treatment] Please select other trial shot range or go back to the Production Program Editor
to examine the Placement data.
E500212 “There is no pick point on both left and right sides in Fully
Synchronized mode”
[Cause] There is a component which pick point exists only on one side.
[Treatment] Please go to the Production Program Editor and see the Pick data.
83
E500213 “The program can not be produced in the <%s> Production mode”
[cause] The production can not be performed with the specified production mode.
? : Production mode
Input order
Optimization order
[Treatment] In the Production dialog, please select a production mode that is NOT currently
selected.
E500214 “Reference error from the Pick data to the Component data”
[Cause] The error appears when the Pick data and Component data are broken.
[Treatment] This is a program error. Please make a note of the cause of the error and the
error code, then contact our technical service Dept. for information.
E500215 “In the accumulative mode, the number of PWBs to be produced is
the same as that of produced PWBs. Production can not be
executed”
[Cause] [accumulate the number of produced PWBs] is checked in the Operation option,
and the number of produced PWBs in the Production dialog already exceeded
the number of PWBs to be produced. Therefore, the production can not be
started.
[Treatment] Please re-set a number of PWBs to be produced that is bigger than the number
of produced PWBs, or disable [accumulate the number of produced PWBs] in the
Operation option.
E500220 “Device enable of setup does not match pick data”
[Cause] There is a Component or Pick data that is from a feeder which is not set ‘to use’
in the Setup.
[Treatment] Please go to the Production Program Editor and see the Component and Pick
data.
E500300 “Origin retrieval has not yet been completed”
[Cause] You tried to resume the production without completing the Origin retrieval after an
unexpected stop such as Emergency stop.
[Treatment] Please perform the Origin retrieval by pressing the ORIGIN button on the
operation panel.
E500301 “Servo is turned OFF”
[Cause] The production can not be executed since the Servo is free.
[Treatment] Please perform the Origin retrieval by pressing the ORIGIN button on the
operation panel.
E500302 “Air was down”
[Cause] The air pressure is getting down.
[Treatment] Please adjust the air pressure to its original level.